...In the world of cabling there are two types of cables and they are Copper and Fiber Optics. Some companies chose fiber over copper but those companies have the money to use Fiber Optics and some just go with copper because it is cheaper to use. Each of these two cables has its own strengths and weaknesses. Copper: Conductivity and Heat Resistant Copper wires are second only to silver when it comes to electrical conductivity. Compared with other non-precious metals, copper wires can handle a wider load of electrical power, allowing it to use less insulation and armoring. They have high resistance to heat, eliminating most issues of overloading. Copper wires are also resistant to corrosion. Although patina, a tarnish produced by oxidation, might be present, the material will not lose functionality. Malleability and Ductility Copper has a high ductility, allowing wires thinner than human hair strands. Malleability allows it to be bent into nearly any form without the threat of breaking. Copper is used to create thick electrical cable wires within electrical posts and in applications where very thin wires are need, such as in headphone wires. Small Amounts of Electricity Although copper wires are excellent conductors, it does not perform very well when handling very exact amounts of small electrical charges. Copper wires are usually not used in high-tech automotive parts and semiconductors because of its inability to control electrical surges. Manufacturers and makers of...
Words: 1086 - Pages: 5
...EXECUTIVE SUMMARY You may ask yourself what is needed for a new building and what are the codes that must be followed in order to have a building nice and free of hazards. Well to start here are the new building requirements for the following materials: patch cables, cat 6 cables, fiber optic multi-mode, cable trays, Cisco- WS-C3750 G24PS-S 24 Ports, laser printer, vertical runs, computers, Cisco border router, server run a and server run b. The following codes must be in play to ensure the building or work space is safe for everyone. 1. American National Standards Institute (ANSI). 2. Electronic Industries Alliance (EIA) 3. Telecommunications Industry Association (TIA) 4. Insulated Cable Engineers Association (ICEA) 5. National Fire Protection Association (NFPA) 6. National Electrical Manufacturers Association (NEMA) 7. Federal Communication Commission (FCC) 8. Underwriters Laboratories (UL) 9. International Organization for Standardization (ISO) 10. International Electrotechnical Commission (IEC) 11. Institute of Electrical and Electronic Engineers (IEEE) 12. National Institute of Standards and Technology (NIST) 13. International Telecommunications Union (ITU) 14. CSA International (CSA) 15. IP/MPLS Forum (ATM Forum) 16. European Telecommunications Standards Institute (ETSI) 17. Building Industry Consulting Services International (BICSI) 18. Occupational Safety and Health Administration (OSHA) 19. ANSI/TIA-568-C Cabling Standard The following...
Words: 1121 - Pages: 5
...Unit 6 Assignment 1 Cable Testers Today we will be discussing different types of cable testers. There are many different types of cable testers. Some would include: wire-map testers, continuity testers, tone generators, time-domain reflectometers, fiber-optic power meters, fiber-optic test sources, optical loss test set, optical time-domain reflectometers, fiber-optic inspection microscopes, visual fault locators, and multifunction cable scanners. We will only be talking about three of these testers. Those three are wire-map testers, time domain-reflectometers, and optical loss test sets. Wire-map testers are testers that transmit signals through each wire in a copper twisted pair cable to determine if it is connected to the correct pin at each end. Wire-map testers detect misplaced wires, broken or unconnected wires, and shorts. The more expensive types of wire-map testers are capable of detecting all problems that can render a cable run inoperable. Though the best models of these can be costly, being able to determine the exact problem immediately is much better than having to keep guessing and checking. I believe that these should be with every technician who values there time in the field, and doesn’t want to spend hours defining a problem only to find more faults. Personally I think these testers should be in EVERY tool kit for wire techs. This could help save a significant amount of time determining the problem with cables. Time domain-reflectometers are the next piece...
Words: 476 - Pages: 2
...UNIT 6. ASSIGMENT 1. CABLE TESTERS. THE THREE CABLES TESTERS I WOULD PICK IN MY LINE UP WOULD BE THE OPTICAL LOSS TEST SET AND TEST KIT, THE TDR, AND THE TONE GENERATORS. THE OPTICAL LOSS TEST SET AND KITS WORKS MORE SO IN A LAB BASED SET UP THEN OUT ON THE FIELD BUT THE TEST KITS IS MORE FAVORABLE BY FIBER TECHS BECAUSE IT HAS A POWER METER AND LIGHT SOURCE THAT ARE MADE TO WORK TOGETHER. THE TDR (TIME DOMAIN REFLECTOR) IS A TOOL THAT IS USED BE SENDING A TONE OR / BEAM OF LIGHT (WITH A DATA ON IT SOME TIMES) AND WILL MEASURE HOW LONG IT TOOK FOR THAT TONE TO REACH THE DESTINE PLACE AND OR BACK TO THE SENDER FROM WHICH IT CAME. AND DEPENDING ON HOW LONG IT TAKES TO COME BACK (IF IT EVER DOES) WILL USUALLY LET YOU KNOW WHERE YOUR FAULT IS IN TYOU NETWORK CABLING THE TONE GENERATOR IS USED BY GENERATING A CERATIN TONE ALONG THE CABLING TO LET YOU KNOW WHERE EXACTLY YOU INCOSISTANCIES ARE WITH IN THAT SPECIFIC CABLE. THE OPTICAL LOSS TEST SET AND TEST KITS WILL SEEM TO WORK BEST WITH FIBER BASED LAYOUT, THE TIME DEFLECTIVE DOMAIN WILL WORK BEST ON THICKNET CABLING SET UPS AND THE TONE GENERATOR WILL WORK BEST ON COPPER/COAXIL LIKE SET UPS. THE TWO TESTER I THINK SHOULD BE IN EVER TECHS INSTALL KITS WILL BE THE TDR AND THE OPTICAL LOSS TEST SET AND TEST KITS THE REASON WHY IS THAT BOTH OF THESE TESTERS CAN SEND TESTING SIGNALS DOWN A CABLE THAT GOES IN OR THRU WALL OR TIGHT SPACES THAT THE HUMAN HAND CANT REACH NOT THE EYE CAN SEE, ALSO MOST OF THESE TESTERS WILL GIVE YOU...
Words: 312 - Pages: 2
...The transition from a Socialist approach to a free market approach and the rise of a new high-tech sector are two remarkable shifts that have occurred in the last two decades in Israel. In the face of these changes, human resource (HR) practitioners are currently expected to assume new roles, adopt different work values, and apply appropriate strategies. HR managers in the low-tech industry still adhere to traditional values and strategies, including a reliance on trade unions and an emphasis on job security and the employees’ years of work experience and seniority as key criteria for promotion. In the emerging high-tech sector, HR managers have adopted new values and developed new strategies, including human resource management programs, employee empowerment, higher salaries and better benefits, while placing an emphasis on employees’ talents and qualifications. Source: http://www.emeraldinsight.com/journals.htm/journals.htm?issn=01437720&volume=22&issue=3&articleid=848302&show=html&PHPSESSID=qj5kp1babsuadbfaj 47luam41 Recent changes in Israeli society and economy and their relation to Organizational Politics Over the past three decades, Israel has undergone significant economic, industrial and cultural transformations. These developments have shifted public values considerably and may indirectly affect OP and HR practices. For example, Sagie and Weisberg (2001) maintain that in recent years, Israeli society has gone from being ascetic...
Words: 1651 - Pages: 7
...CHINA BOOST FOR SENAI HI-TECH PARK Senai Hi-Tech Park, Malaysia's second high technology industrial park, got off to a promising start with investments of more than US$500 million (RM1.7 billion) from two companies in Johor. China-based EQ Solar Technology International Sdn Bhd plans to invest US$500 million to produce solar modules while leading industrial gases provider MOX-Linde Gases Sdn Bhd, through its initial outlay of RM60 million, plans to set up an industrial gases separation plant. Senai High Tech Park chief executive officer (CEO) Datuk Ahmad Shukri Tajudin said this shows that the park is ready to compete as another preferred location for hightechnology manufacturing, research and innovation activities. Located within Iskandar Malaysia, the park has drawn interest from investors in the US, Europe and China. "Interest is in various sectors including semiconductor industry and solar," he said at a media briefing. International Trade and Industry Minister Datuk Seri Mustapa Mohamed, witnessed the signing of the memorandum of understanding in Kuala Lumpur yesterday. "We're expecting a few more similar investments," Mustapa said, without disclosing details. Malaysia has so far attracted several global solar industry players like First Solar, Sunpower and Q-Cells. There are also several domestic investments in solar power projects in Selangor and Sabah. Mustapa hopes that the park will create more jobs, similar to what was achieved at the Kulim Hi-Tech Park in the north. The...
Words: 452 - Pages: 2
...over the years. Guillermo Furniture Store Recommendation Analysis and Recommend Financial Decision The economy is weak, new competitors’ establishing a presents, Guillermo must tackle a tough decision, which is to become a furniture distributor or stay on the manufacturing side, or possibility do both. Guillermo understands that change is forth coming and he has to venture forward but the dilemma is what the best alternative is. First Guillermo must analysis the financial alternatives and establish which objective is beneficial for the company. The next step is to gather information and formulate a pro forma cash flow budget to analyze the projected earnings for the next five years for the company (University of Phoenix, 2007). Hi-Tech Option Guillermo established his wealth various years ago because of the low cost in labor along with an extraordinary location for manufacturing. The company’s success has held strong on those foundations until now. There are a few concerns for Guillermo that may cause the company to change the way it does...
Words: 2497 - Pages: 10
...strategy-oriented HR system case study 1. * Strategically required organizational outcomes: * Good products and good services. Products and services is always the most important thing for a manufacturing company. Siemens has become a world leader by diversifying into hi-tech products and services, it need to maintain this advantage and develop it even further to achieve more. * Going global and expand. Globalization gives big companies a chance to expand rapidly. Siemens has succeeded in going global but this is a long way, it still needs more expansion into more countries or areas that are not covered yet. * Positive brand image. A good company image is extraordinarily important to the company’s healthy development. Siemens needs to keep customers satisfied both with its products and services, which helps it to get more market share and expand even faster. * A good employee selection, training and compensation system. The company not just need to keep customers satisfied, it has to keep employees happy too. So that it can work more efficiently and effectively. * Required workforce competencies and behaviors: * Learning on a continuing basis. Siemens is in high-tech business so the nature decided that its employees need to learn new things every day. * Good teamwork. The ability to work with people is essential in such big corporation. Especially when it’s going global. * Mutual respect and appreciation of workforce diversity. Siemens...
Words: 296 - Pages: 2
...I think before going into details, we should understand what is backbone. After a lot of research, I came up this definition; a backbone is a means of connecting two or more LANs. It provides a transmission channel for packets being transmitted from one LAN to another. After connection to a backbone, a LAN may remain distinct or be merged with another. Backbone networks can be applied to a single building environment as well as to campus environments, where the backbone is used to connect LANs in different buildings. Parallel backbone: I think parallel back is the best worth it for any company. The additional cost of setting up a parallel backbone can be well worth the money. The design of this type of backbone consists of using two cables routed between the routers and switches. While there are additional initial costs of installing a parallel backbone, the benefits can quickly outweigh these costs. However if company wants to save some money, they can use distribute network. It consists of a number of connectivity devices connected to a series of central connectivity devices, such as hubs, switches, or routers, in a hierarchy. This kind of topology allows for simple expansion and limited capital outlay for growth, because more layers of devices can be added to existing layers The enterprise network is challenging because it rapidly changing as new applications and architectures, including Linux, computing clusters, voice over IP applications, become central to the business...
Words: 731 - Pages: 3
...each wire in a copper twisted-pair cable to determine if it is connected to the correct pin at each end. Wire-map testers detect transposed wires, opens, and shorts which are all problems that can render a cable useless. A wire-map tester consists of a remote unit that you attach to the far end of a connection and the battery-operated, handheld main unit that displays the results. Typically, the tester displays various codes to describe the type of faults it finds, so you know which part of the cable you messed up on or what else may be wrong with it. Tone Generators Tone generators are the simplest type of copper cable tester. A tone generator is made up of two parts, a tone generator and a probe. These are sometimes referred to as a fox and hound wire tracer. With a standard jack, you connect to the cable the unit that transmits a signal, or, with an alligator clip, you connect the unit to an individual wire. The other unit is an inductive amplifier, which is a pen like probe that emits an audible tone when touched to the other end of the conductor. Tone generators are most often used to locate a specific connection in a punch-down block. Using a tone generator is extremely time-consuming and it is nearly as prone to errors as the cable installation. Time-Domain Reflectometers A TDR is the primary tool used to determine the length of a copper cable and to locate the impedance variations that are caused by opens, shorts, damaged cables, and interference with other systems...
Words: 482 - Pages: 2
...The ethical issue at Bryson Corporation is whether or not Stanton Wong, the quality supervisor, should ignore defects in a batch of laminated cable they had produced. As directed by his plant manager Harry Jackson, Stanton still should supply their client’s inspector with the defected cables. According to protocol, Bryson Corporation required a test failure be reported for such results. The cables are used to assembly fuses in missiles for the U.S. military. If there were any faulty cables used in production, it could result in severe consequences. Many innocent civilians and soldiers can possibly be harmed. If I were Stanton Wong, I would not give the client the defected cables. I would definitely contact senior management and disclose them of the situation at the plant. As the quality supervisor, I’m responsible for the all the cables and if a cable isn’t up to par, I would be held liable. Additionally, I would approach Jane Conway, the client’s inspector, and request her to perform her own elevated seal heat test from now on. This scenario says a lot about the ethical situation at Bryson Corporation. It is quite obvious that Bryson Corporation does not have effective ethical precautions in place. They only seem to be concerned with making a profit for the company. As an independent ethical consultant, I would suggest to Bryson Corporation to provide an ethics-training course to all current and future management and employees. It would raise ethical awareness and provide...
Words: 292 - Pages: 2
...In putting in a network there are many aspects to consider such as the Topology or design, what type of hardware to be used, and types of cabling. Copper cables are the norm when it comes to building and network and widely used in our communications of today. Copper has been used in electric wiring since the invention of the electromagnet. Copper and its alloys are also used in buildings is the most important market for the copper industry. The inherent strength, hardness, and flexibility of copper building wire make it very easy to work with. Its flexibility makes it easy to join, while its hardness helps keep connection securely in place. There`s also another type of cabling you can use and its Fiber optic cabling which is becoming more in use in communication. Unlike copper fiber uses optical fiber elements which are typically individually coated with plastic layers and is contained in a protective tube suitable for the environment. Optical fibers are inherently very strong, but is drastically reduced by unavoidable microscopic surface flaws inherent in the manufacturing process. The strength of fiber as well with its change in time, are to be considered relative to the stress impose in today environment. Its benefits out way those of copper, fiber is relative to the stress imposed during handling, cabling, and installation for the set environment. Its signal strength is stronger and faster than copper, and it is not compromised by EMI (electric magnetic interference)...
Words: 262 - Pages: 2
...Remote control HDMI cable (3 m / 10 ft) Ethernet cable (5 m / 16 ft) Power cable (1.8 m / 6 ft) Batteries LR03 AAA 1.5 V for the remote control Assembling the rack ear profiles Mount the rack ear profiles to the codec. IMPORTANT There should always be a distance of minimum 10 cm / 4 in. free space in front of the codec. 1. Remove the two M3 screws on the left and right side of the codec. Tool: Screwdriver, 2 mm Allen Key 2. Use the same two M3 screws to fasten the rack ear profiles to the codec. Min. 10 cm User guides The user documentation for this product, including compliance and safety information, is available on the Cisco web site. Go to: http://www.cisco.com/go/cseries-docs SAFETY REQUIREMENT Make sure the codec is not mounted with the front side up or down. EMC Class A declaration 声 明 此为A级产品,在生活环境中,该产品可能会造成无线电干扰。在这种 情况下,可能需要用户对其干扰采取切实可行的措施。 WARNING: This is a class A product. In a domestica domestic environment WARNING: This is a class A product. In environment this product may cause radio interference inmay cause the user may be required to take adequate measures. this product which case radio interference in which case the user may be required to take adequate measures. Connecting cables For a basic setup, you should go through these steps: 1. Connect the main camera to the HDMI 1 input using a HDMI to HDMI cable. • For camera control you should also connect the camera to the Camera Control input using the dedicated cable that came with your...
Words: 547 - Pages: 3
...Home Page » Computers and Technology Copper vs Fiber In: Computers and Technology Copper vs Fiber Copper vs. Fiber Paper In putting in a network there are many aspects to consider such as the Topology or design, what type of hardware to be used, and types of cabling. Copper cables are the norm when it comes to building and network and widely used in our communications of today. Copper has been used in electric wiring since the invention of the electromagnet. Copper and its alloys are also used in buildings is the most important market for the copper industry. The inherent strength, hardness, and flexibility of copper building wire make it very easy to work with. Its flexibility makes it easy to join, while its hardness helps keep connection securely in place. There`s also another type of cabling you can use and its Fiber optic cabling which is becoming more in use in communication. Unlike copper fiber uses optical fiber elements which are typically individually coated with plastic layers and is contained in a protective tube suitable for the environment. Optical fibers are inherently very strong, but is drastically reduced by unavoidable microscopic surface flaws inherent in the manufacturing process. The strength of fiber as well with its change in time, are to be considered relative to the stress impose in today environment. Its benefits out way those of copper, fiber is relative to the stress imposed during handling, cabling, and installation...
Words: 280 - Pages: 2
...http://ammtiac.alionscience.com/quarterly Larry X Schneider Pulsed Power Sciences Center Sandia National Laboratories Albuquerque, NM The article entitled “Wired for Success: Ensuring Aircraft Wiring Integrity Requires a Proactive Systems Approach”, which was published in Vol. 8, No. 3 of the AMPTIAC Quarterly (a predecessor to the AMMTIAC Quarterly), established the importance of maintaining wiring integrity, especially in aging aircraft. The article also emphasized the need for nondestructive approaches for evaluating the integrity of wiring systems and components. The current article answers the mail in terms of providing a nondestructive inspection (NDI) method to proactively ensure wiring integrity. – Editor INTRODUCTION Detecting and locating insulation defects in wiring systems is a nontrivial challenge. Ideally, the diagnostic should be nondestructive, capable of detecting a variety of insulation defects, such as cracking, chaffing, and abrasion, and be able to locate the defect accurately to reduce potential inspection and maintenance costs. The diagnostic should also have a low rate of false detection. Complicating this quest is the nature of complex wiring systems. For example, aircraft wiring systems are comprised of harnesses containing periodically bound single wire pairs* which create highly non-uniform impedance characteristics due to the varying distance between wire pairs. Insulation defects may also be physically small, resulting in...
Words: 2780 - Pages: 12