Dell™ PowerEdge™ SC1435 Systems

Hardware Owner’s Manual

w w w. d e l l . c o m | s u p p o r t . d e l l . c o m

Downloaded from www.Manualslib.com manuals search engine

Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.

____________________
Information in this document is subject to change without notice. © 2006 Dell Inc. All rights reserved. Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell, the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerConnect, PowerEdge, PowerVault, PowerApp, Dell OpenManage, and Dell XPS are trademarks of Dell Inc.; Microsoft, Windows, MS-DOS, and Windows Server are registered trademarks of Microsoft Corporation; AMD and AMD PowerNow! are trademarks of Advanced Micro Devices, Inc.; EMC is a registered trademark of EMC Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Model SVUA

August 2006

P/N HJ362

Rev. A00

Downloaded from www.Manualslib.com manuals search engine

Contents
1 About Your System .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9
9 10 11 13 13 13 14 14 16 22 22 22

Other Information You May Need

Accessing System Features During Startup . Front-Panel Features and Indicators Back-Panel Features and Indicators Connecting External Devices . Power Indicator Codes. NIC Indicator Codes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Diagnostics Indicator Codes . System Messages

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Warning Messages

Diagnostics Messages . Alert Messages

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Using the System Setup Program
Entering the System Setup Program . Responding to Error Messages . . Using the System Setup Program . System Setup Options

. . . . . . . . . . . . . . . . . .

23
23 23 24 24 24 27 27 28 29 30 30 30 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Main Screen . . . . . . . . Memory Information Screen CPU Information Screen . . Integrated Devices Screen . System Security Screen . . Exit Screen . . . . . . . . .

System and Setup Password Features. Using the System Password Using the Setup Password .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contents

3

Downloaded from www.Manualslib.com manuals search engine

Disabling a Forgotten Password.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

33 33 34 34

Baseboard Management Controller Configuration Entering the BMC Setup Module . BMC Setup Module Options . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Installing System Components
Recommended Tools . Inside the System

. . . . . . . . . . . . . . . . . . . .

35
35 36 37 38 38 39 39 39 40 40 40 41 42 42 43 44 44 45 46 46 46 48 48 49 50 50 52

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Removing and Replacing the Front Bezel . Opening and Closing the System Opening the System . Closing the System . Cooling Shroud .

. . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Removing the Cooling Shroud Replacing the Cooling Shroud Cooling Fan Modules

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Removing a Cooling Fan Module . Replacing a Cooling Fan Module . Power Supply

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Removing the Power Supply Installing the Power Supply. Expansion Cards

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installing an Expansion Card . Removing an Expansion Card . System Memory

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Memory Module Installation Guidelines Sample Memory Configurations . . . . Non-Optimal Memory Configurations . Installing Memory Modules. . . . . . . Removing Memory Modules . . . . . . Processors

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Removing a Processor Installing a Processor .

4

Contents

Downloaded from www.Manualslib.com manuals search engine

Optical Drive .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

54 54 54 55 55 56 56 56 57 58 58 59 59 59 61 61 62 63 63 64

Removing the Optical Drive from the System . . Installing the Optical Drive in the System. . . . Removing the Optical Drive from the Drive Tray Hard Drives .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Optional SAS RAID Controller Before You Begin . . . . . . . Installing a Hard Drive . . . . Configuring the Boot Device . Expansion-Card Riser

. . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Removing an Expansion-Card Riser Installing an Expansion-Card Riser . System Battery

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Replacing the System Battery

Control Panel Assembly (Service-Only Procedure) . Removing the Control Panel Installing the Control Panel .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

System Board (Service-Only Procedure) Removing the System Board Installing a System Board . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Troubleshooting Your System
Safety First—For You and Your System Start-Up Routine

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

67
67 67 68 68 68 69 69 70 70

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking Basic Power Problems Checking the Equipment .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting IRQ Assignment Conflicts . Troubleshooting External Connections . . . Troubleshooting the Video Subsystem . . . Troubleshooting the Keyboard . . . . . . . Troubleshooting the Mouse . . . . . . . . .

Contents

5

Downloaded from www.Manualslib.com manuals search engine

Troubleshooting Basic I/O Functions

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

70 71 71 72 72 73 74 74 75 75 76 78 78 79 80 82

Troubleshooting a Serial I/O Device Troubleshooting a USB Device . . . Troubleshooting a NIC

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting a Wet System.

Troubleshooting a Damaged System. Troubleshooting the System Battery . Troubleshooting the Power Supply

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting System Cooling Problems Troubleshooting a Fan

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting System Memory Troubleshooting an Optical Drive Troubleshooting a Hard Drive

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting a SAS RAID Controller Card . Troubleshooting an Expansion Card .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting the Microprocessors

5

Running the System Diagnostics .
Using Dell PowerEdge Diagnostics . System Diagnostics Features

. . . . . . . . . . . . . . . . . .

85
85 85 86 86 86 87 87 87 87

. . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

When to Use the System Diagnostics Running the System Diagnostics

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

System Diagnostics Testing Options. Using the Custom Test Options

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting Devices for Testing . . . Selecting Diagnostics Options . . Viewing Information and Results .

6

Contents

Downloaded from www.Manualslib.com manuals search engine

6

Jumpers and Connectors .
System Board Jumpers. Disabling a Forgotten Password. System Board Connectors Riser Boards

. . . . . . . . . . . . . . . . . . . . . . .

89
89 90 92 94

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Getting Help

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

95
95 95 96 96 96 97 97 97 97 98 100

Technical Assistance

Online Services . . . . . . . . . . AutoTech Service . . . . . . . . . Automated Order-Status Service . Technical Support Service . . . .

Dell Enterprise Training and Certification . Problems With Your Order . Product Information

. . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Returning Items for Warranty Repair or Credit Before You Call . Contacting Dell .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Glossary Index .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

121 129

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contents

7

Downloaded from www.Manualslib.com manuals search engine

8

Contents

Downloaded from www.Manualslib.com manuals search engine

About Your System
This section describes the physical, firmware, and software interface features that provide and ensure the essential functioning of your system. The physical connectors on your system’s front and back panels provide convenient connectivity and system expansion capability. The system firmware, applications, and operating systems monitor the system and component status and alert you when a problem arises. System conditions can be reported by any of the following: • • • • • Front or back panel indicators System messages Warning messages Diagnostics messages Alert messages

This section describes each type of message, lists the possible causes, and provides steps to resolve any problems indicated by a message. The system indicators and features are illustrated in this section.

Other Information You May Need
CAUTION: The Product Information Guide provides important safety and regulatory information. Warranty information may be included within this document or as a separate document. • • • • • • The Rack Installation Guide or Rack Installation Instructions included with your rack solution describes how to install your system into a rack. The Getting Started Guide provides an overview of system features, setting up your system, and technical specifications. CDs included with your system provide documentation and tools for configuring and managing your system. Systems management software documentation describes the features, requirements, installation, and basic operation of the software. Operating system documentation describes how to install (if necessary), configure, and use the operating system software. Documentation for any components you purchased separately provides information to configure and install these options.

About Your System

9

Downloaded from www.Manualslib.com manuals search engine



Updates are sometimes included with the system to describe changes to the system, software, and/or documentation. NOTE: Always check for updates on support.dell.com and read the updates first because they often supersede information in other documents.



Release notes or readme files may be included to provide last-minute updates to the system or documentation or advanced technical reference material intended for experienced users or technicians.

Accessing System Features During Startup
Table 1-1 describes keystrokes that may be entered during startup to access system features. If your operating system begins to load before you enter the keystroke, allow the system to finish booting, and then restart your system and try again.
Table 1-1. Keystroke Keystrokes for Accessing System Features Description Enters the System Setup program. See "Using the System Setup Program" on page 23. Enters the System Diagnostics program. See "Running the System Diagnostics" on page 86. Enters the boot mode selections screen, allowing you to choose a boot device. Exits PXE boot. Enters the Baseboard Management Controller (BMC) Setup Module, which allows access to the system event log (SEL). See the BMC User’s Guide for more information on setup and use of BMC. Enters the SAS Configuration Utility. See your optional SAS adapter User’s Guide for more information. Option is displayed only if you have PXE support enabled through the System Setup Program (see "Integrated Devices Screen" on page 28). This keystroke allows you to configure NIC settings for PXE boot. For more information, see the documentation for your integrated NIC.

10

About Your System

Downloaded from www.Manualslib.com manuals search engine

Front-Panel Features and Indicators
Figure 1-1 shows the controls, indicators, and connectors located behind the optional rack bezel on the system's front panel.
Figure 1-1. Front-Panel Features and Indicators 2 1 8 3 4 5 6 7

Table 1-2. Item 1

Front-Panel Indicators, Buttons, and Connectors Indicator, Button, or Connector Power-on indicator, power button Icon Description The power button controls the DC power supply output to the system. NOTE: If you turn off the system using the power button and the system is running an ACPI-compliant operating system, the system performs a graceful shutdown before the power is turned off. If the system is not running an ACPI-compliant operating system, the power is turned off immediately after the power button is pressed. Used to troubleshoot software and device driver errors when using certain operating systems. This button can be pressed using the end of a paper clip. Use this button only if directed to do so by qualified support personnel or by the operating system's documentation.

2

NMI button

3

System identification button

The identification buttons on the front and back panels can be used to locate a particular system within a rack. When one of these buttons is pushed, the blue system status indicator on the front and back blinks until one of the buttons is pushed again.

About Your System

11

Downloaded from www.Manualslib.com manuals search engine

Table 1-2. Item 4 5

Front-Panel Indicators, Buttons, and Connectors (continued) Indicator, Button, or Connector Diagnostics indicator lights (4) System status indicator light Icon Description The four diagnostic indicator lights on the system front panel display error codes during system startup. Lights blue during normal system operation. Both the systems management software and the identification buttons located on the front and back of the system can cause the indicator to flash blue to identify a particular system. Lights amber when the system needs attention due to a problem.

6 7 8

USB connectors (2) Video connector Optical drive (optional)

Connects USB 2.0-compliant devices to the system. Connects a monitor to the system. One optional slimline optical drive

NOTE: DVD devices are data only.

12

About Your System

Downloaded from www.Manualslib.com manuals search engine

Back-Panel Features and Indicators
Figure 1-2 shows the controls, indicators, and connectors located on the system's back panel.
Figure 1-2. Back-Panel Features and Indicators 1 2 3 4 5 6 7

12 1 4 7 serial connector NIC1 connector power cable retention bracket 2 5 8 11

11 video connector NIC2 connector

10

9

8 3 6 9 12

expansion slot power connector system status indicator USB connector

system identification button USB connector

10 system status indicator LED cable connector

Connecting External Devices
When connecting external devices to your system, follow these guidelines: • Most devices must be connected to a specific connector and device drivers must be installed before the device operates properly. (Device drivers are normally included with your operating system software or with the device itself.) See the documentation that accompanied the device for specific installation and configuration instructions. Always attach external devices while your system is turned off. Next, turn on any external devices before turning on the system (unless the documentation for the device specifies otherwise).



For information about individual connectors, see "Jumpers and Connectors" on page 89. For information about enabling, disabling, and configuring I/O ports and connectors, see "Using the System Setup Program" on page 23.

Power Indicator Codes
The power button on the front panel controls the power input to the system's power supply. The power indicator can provide information on power status (see Figure 1-1). Table 1-3 lists the power button indicator codes.

About Your System

13

Downloaded from www.Manualslib.com manuals search engine

Table 1-3. Power Button Indicators Indicator On Off Function Indicates that power is supplied to the system and the system is operational. Indicates that no power is supplied to the system.

NIC Indicator Codes
Each NIC on the back panel has an indicator that provides information on network activity and link status. See Figure 1-3. Table 1-4 lists the NIC indicator codes.
Figure 1-3. NIC Indicators 1 2

1

link indicator

2

activity indicator

Table 1-4. NIC Indicator Codes Indicator Link and activity indicators are off Link indicator is green Activity indicator is amber blinking Indicator Code The NIC is not connected to the network. The NIC is connected to a valid link partner on the network. Network data is being sent or received.

Diagnostics Indicator Codes
The four diagnostic indicator lights on the system front panel display error codes during system startup. Table 1-5 lists the causes and possible corrective actions associated with these codes. A highlighted circle indicates the light is on; a non-highlighted circle indicates the light is off. NOTE: Once the system completes POST, all diagnostic lights will be OFF.

14

About Your System

Downloaded from www.Manualslib.com manuals search engine

Table 1-5. Code

Diagnostic Indicator Codes Causes Possible processor failure. Corrective Action See "Troubleshooting the Microprocessors" on page 82.

Memory failure.

See "Troubleshooting System Memory" on page 76.

Possible expansion card failure. Possible video failure.

See "Troubleshooting an Expansion Card" on page 80.

See "Getting Help" on page 95.

Hard drive failure.

Ensure that the hard drive is properly connected. See "Troubleshooting a Hard Drive" on page 78. See ""Troubleshooting a USB Device" on page 71.

Possible USB failure.

No memory modules detected. System board failure.

See "Troubleshooting System Memory" on page 76.

See "Getting Help" on page 95.

Memory configuration error.

See "Troubleshooting System Memory" on page 76.

Possible system board See "Troubleshooting IRQ Assignment Conflicts" on resource and/or system board page 68. If the problem persists, see "Getting Help" on hardware failure. page 95. Possible system resource configuration error. Other failure. See "Troubleshooting IRQ Assignment Conflicts" on page 68. If the problem persists, see "Getting Help" on page 95. Ensure that the optical drive and hard drives are properly connected. See "Troubleshooting an Optical Drive" on page 78 or "Troubleshooting a Hard Drive" on page 78. If the problem persists, see "Getting Help" on page 95.

About Your System

15

Downloaded from www.Manualslib.com manuals search engine

Table 1-5. Code

Diagnostic Indicator Codes (continued) Causes BIOS checksum failure detected; system is in recovery mode. Corrective Action Ensure that all network connections are functioning properly. See ""Troubleshooting Your System" on page 67." If the problem persists, see ""Getting Help" on page 95."

System Messages
System messages appear on the screen to notify you of a possible problem with the system. Table 1-6 lists the system messages that can occur and the probable cause and corrective action for each message. NOTE: If you receive a system message that is not listed in Table 1-6, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action. CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.
Table 1-6. Message Alert! Node Interleaving disabled! Memory configuration does not support Node Interleaving. System Messages Causes The memory configuration does not support node interleaving. The system will run but with reduced functionality. Corrective Actions Ensure that the memory modules are installed in a configuration that supports node interleaving. See "Memory Module Installation Guidelines" on page 46. If the problem persists, see "Troubleshooting System Memory" on page 76. Wait until the process is complete.

Attempting to update Remote Configuration. Please wait... BIOS Update Attempt Failed!

Remote Configuration request has been detected and is being processed. Remote BIOS update attempt failed.

Retry the BIOS update. If problem persists, see "Getting Help" on page 95. Remove the NVRAM_CLR jumper. See Figure 6-1 for jumper location.

Caution! NVRAM_CLR jumper NVRAM_CLR jumper is installed. is installed on system CMOS has been cleared. board.

16

About Your System

Downloaded from www.Manualslib.com manuals search engine

Table 1-6. Message

System Messages (continued) Causes Incorrect configuration settings in the System Setup program. Faulty or improperly installed diskette drive. Corrective Actions Run the System Setup program to correct the settings. See "Using the System Setup Program" on page 23. Replace the diskette. If the problem persists, see "Troubleshooting a USB Device" on page 71.

Diskette drive n seek failure

Loose diskette drive interface cable. Reconnect the diskette drive USB cable. See "Troubleshooting a USB Device" on page 71. Diskette read failure Faulty or improperly inserted diskette. Faulty or improperly installed diskette. Replace the diskette. If the problem persists, see "Troubleshooting a USB Device" on page 71. Replace the diskette. If the problem persists, see "Troubleshooting a USB Device" on page 71.

Diskette subsystem reset failed Drive not ready

Diskette missing from or improperly Replace the diskette. If the problem inserted in diskette drive. persists, see "Troubleshooting a USB Device" on page 71. Invalid memory configuration. Ensure that the memory modules are installed in a valid configuration. See "Memory Module Installation Guidelines" on page 46. If the problem persists, see "Troubleshooting System Memory" on page 76.

Error: Incorrect memory configuration. CPUn System Halted!

Error: Memory failure detected. Memory size reduced. Replace the faulty DIMM as soon as possible. Remote configuration update attempt failed Fatal error caused a system reset: Please check the system event log for details. Gate A20 failure

Faulty or improperly seated memory See "Troubleshooting System Memory" module(s). on page 76.

System unable to process Remote Configuration request. Fatal system error.

Retry Remote Configuration. Check the system event log for the specific cause, then see the appropriate section in"Troubleshooting Your System" on page 67. See "Getting Help" on page 95.

Faulty keyboard controller; faulty system board.

About Your System

17

Downloaded from www.Manualslib.com manuals search engine

Table 1-6. Message

System Messages (continued) Causes The operating system is unable to carry out the command. Corrective Actions This message is usually followed by specific information. Note the information and take the appropriate action to resolve the problem. No action is required.

General failure

Invalid NVRAM configuration, Resource Re-allocated Keyboard Controller failure Manufacturing mode detected Memory address line failure at address, read value expecting value Memory double word logic failure at address, read value expecting value Memory odd/even logic failure at address, read value expecting value Memory write/read failure at address, read value expecting value Memory tests terminated by keystroke. No boot device available

System detected and corrected a resource conflict. Faulty keyboard controller; faulty system board System is in manufacturing mode. Faulty or improperly installed memory modules.

See "Getting Help" on page 95. Reboot to take the system out of manufacturing mode. See "Troubleshooting System Memory" on page 76.

POST memory test terminated by pressing the spacebar. Faulty or missing optical/diskette drive subsystem, hard drive, or harddrive subsystem, or no boot disk in drive A.

Information only. Use a bootable diskette, CD, or hard drive. If the problem persists, see "Troubleshooting a USB Device" on page 71, "Troubleshooting an Optical Drive" on page 78, and "Troubleshooting a Hard Drive" on page 78. See "Using the System Setup Program" on page 23 for information about setting the order of boot devices.

18

About Your System

Downloaded from www.Manualslib.com manuals search engine

Table 1-6. Message

System Messages (continued) Causes Incorrect configuration settings in System Setup program, or no operating system on hard drive. Corrective Actions Check the hard-drive configuration settings in the System Setup program. See "Using the System Setup Program" on page 23. If necessary, install the operating system on your hard drive. See your operating system documentation. See "Getting Help" on page 95. Use a bootable diskette. Reseat the PCIe card in the specified slot number. See "Installing an Expansion Card" on page 44. If the problem persists, see "Getting Help" on page 95. Reseat the PCIe card in the specified slot number. See "Installing an Expansion Card" on page 44. If the problem persists, see "Getting Help" on page 95. Reseat the PCIe card in the specified slot number. See "Installing an Expansion Card" on page 44. If the problem persists, see "Getting Help" on page 95.

No boot sector on hard drive

No timer tick interrupt Not a boot diskette PCIe Degraded Link Width Error: Embedded Bus#nn/Dev#nn/Funcn Expected Link Width is n Actual Link Width is n PCIe Degraded Link Width Error: Slot n Expected Link Width is n Actual Link Width is n

Faulty system board. No operating system on diskette. Faulty or improperly installed PCIe card in the specified slot.

Faulty or improperly installed PCIe card in the specified slot.

PCIe Fatal Error caused a Faulty or improperly installed PCIe system reset: Slot n card in the specified slot.

or
Embedded Bus#nn/Dev#nn/Funcn Please check the system event log for details. PCI BIOS failed to install PCI device BIOS (Option ROM) checksum failure is detected during shadowing. Loose cables to expansion card(s); faulty or improperly installed expansion card.

Reseat the expansion cards. Ensure that all appropriate cables are securely connected to the expansion cards. If the problem persists, see "Troubleshooting an Expansion Card" on page 80. Install the NVRAM_CLR jumper and reboot the system. See Figure 6-1 for jumper location. If the problem persists, see "Troubleshooting an Expansion Card" on page 80.

Plug & Play Configuration Error encountered in initializing Error PCI device; faulty system board.

About Your System

19

Downloaded from www.Manualslib.com manuals search engine

Table 1-6. Message

System Messages (continued) Causes The operating system cannot read from the diskette or hard drive, the system could not find a particular sector on the disk, or the requested sector is defective. Corrective Actions Replace the diskette. Ensure that the diskette and hard drive cables are properly connected. See "Troubleshooting a USB Device" on page 71, "Troubleshooting an Optical Drive" on page 78, or "Troubleshooting a Hard Drive" on page 78 for the appropriate drive(s) installed in your system. Retry Remote Configuration.

Read fault Requested sector not found

Remote configuration update attempt failed ROM bad checksum = address

System unable to process Remote Configuration request.

Expansion card improperly installed Reseat the expansion cards. Ensure or faulty. that all appropriate cables are securely connected to the expansion cards. If the problem persists, see "Troubleshooting an Expansion Card" on page 80. SATA cables are not properly seated, See "Troubleshooting a Hard Drive" on or drive missing. page 78. Faulty diskette or hard drive. See "Troubleshooting a USB Device" on page 71 or "Troubleshooting a Hard Drive" on page 78 for the appropriate drive. See "Troubleshooting System Memory" on page 76.

SATA port n hard disk drive not found Sector not found Seek error Seek operation failed Shutdown failure The amount of system memory has changed

Shutdown test failure.

Memory has been added or removed If memory has been added or removed, or a memory module may be faulty. this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See "Troubleshooting System Memory" on page 76. Install a supported microprocessor or microprocessor combination. See "Processors" on page 50. See "Troubleshooting the System Battery" on page 74.

This system supports only Microprocessor(s) is not supported Opteron 2000 series by the system. processors. Time-of-day clock stopped Faulty battery or faulty chip.

20

About Your System

Downloaded from www.Manualslib.com manuals search engine

Table 1-6. Message

System Messages (continued) Causes Incorrect Time or Date settings; faulty system battery. Corrective Actions Check the Time and Date settings. See "Using the System Setup Program" on page 23. If the problem persists, replace the system battery. See "System Battery" on page 59. See "Getting Help" on page 95. Install a supported microprocessor or microprocessor combination. See "Processors" on page 50.

Time-of-day not set please run SETUP program

Timer chip counter 2 failed Unsupported CPU combination Unsupported CPU stepping detected Utility partition not available

Faulty system board. Microprocessor(s) is not supported by the system.

The key was pressed during Create a utility partition on the boot POST, but no utility partition exists hard drive. See the CDs that came on the boot hard drive. with your system.

Warning: DIMM n and n are Faulty or improperly seated memory See "Troubleshooting System Memory" faulty and disabled. module(s). on page 76. Total memory size is reduced! Warning! No microcode update loaded for processor n Warning: One or more faulty DIMMs found on CPUn Warning: The installed memory configuration is not optimal. For more information on valid memory configurations, please see the system documentation on the technical support web site. Write fault Write fault on selected drive Microcode update failed. Update the BIOS firmware. See "Getting Help" on page 95.

Faulty or improperly seated memory See "Troubleshooting System Memory" module(s) used by CPUn. on page 76. Invalid memory configuration. The system will run but with reduced functionality. Ensure that the memory modules are installed in a valid configuration. See "Memory Module Installation Guidelines" on page 46. If the problem persists, see "Troubleshooting System Memory" on page 76.

Faulty diskette, optical/diskette drive assembly, hard drive, or harddrive subsystem.

See "Troubleshooting a USB Device" on page 71, "Troubleshooting an Optical Drive" on page 78, or "Troubleshooting a Hard Drive" on page 78.

NOTE: For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 121.

About Your System

21

Downloaded from www.Manualslib.com manuals search engine

Warning Messages
A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a diskette, a message will warn you that you may lose all data on the diskette. Warning messages usually interrupt the task and require you to respond by typing y (yes) or n (no). NOTE: Warning messages are generated by either the application or the operating system. For more information, see the documentation that accompanied the operating system or application.

Diagnostics Messages
When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record the message on a copy of the Diagnostics Checklist in "Getting Help" on page 95, and then follow the instructions in that section for obtaining technical assistance.

Alert Messages
Systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.

22

About Your System

Downloaded from www.Manualslib.com manuals search engine

Using the System Setup Program
After you set up your system, run the System Setup program to familiarize yourself with your system configuration and optional settings. Record the information for future reference. You can use the System Setup program to: • • • • Change the system configuration stored in NVRAM after you add, change, or remove hardware Set or change user-selectable options—for example, the time or date Enable or disable integrated devices Correct discrepancies between the installed hardware and configuration settings

Entering the System Setup Program
1 Turn on or restart your system. 2 Press immediately after you see the following message (you may have to press the key more than once): = System Setup If your operating system begins to load before you press , allow the system to finish booting, and then restart your system and try again. NOTE: To ensure an orderly system shutdown, see the documentation that accompanied your operating system. Responding to Error Messages
You can enter the System Setup program by responding to certain error messages. If an error message appears while the system is booting, make a note of the message. Before entering the System Setup program, see "System Messages" on page 16 for an explanation of the message and suggestions for correcting errors. NOTE: After installing a memory upgrade, it is normal for your system to send a message the first time you start your system.

Using the System Setup Program

23

Downloaded from www.Manualslib.com manuals search engine

Using the System Setup Program
Table 2-1 lists the keys that you use to view or change information on the System Setup program screens and to exit the program.
Table 2-1. Keys Up arrow or Down arrow or Spacebar, , , left and right arrows System Setup Program Navigation Keys Action Moves to the previous field. Moves to the next field. Cycles through the settings in a field. In many fields, you can also type the appropriate value. From the main menu, selects an option that has a submenu, such as Memory Information. From a submenu, returns the program to the main menu. From the main menu, exits the System Setup program and restarts the system if any changes were made. Displays the System Setup program's help file.

NOTE: For most of the options, any changes that you make are recorded but do not take effect until you restart the system. System Setup Options
Main Screen
When you enter the System Setup program, the main System Setup program screen appears (see Figure 2-1).

24

Using the System Setup Program

Downloaded from www.Manualslib.com manuals search engine

Figure 2-1. Main System Setup Program Screen

Table 2-2 lists the options and descriptions for the information fields that appear on the main System Setup program screen. For related information, see "System Security Screen Options" on page 29. NOTE: The options for the System Setup program change based on the system configuration. NOTE: The System Setup program defaults are listed under their respective options, where applicable.
Table 2-2. Option System Time System Date Memory Information CPU Information System Setup Program Options Description Resets the time on the system's internal clock. Resets the date on the system's internal calendar. Displays information related to installed memory. See "Memory Information Screen" on page 27. Displays information related to microprocessors (speed, cache size, and so on). See "CPU Information Screen" on page 27.

Using the System Setup Program

25

Downloaded from www.Manualslib.com manuals search engine

Table 2-2. Option

System Setup Program Options (continued) Description Determines the order in which the system searches for boot devices during system startup. Available options can include the diskette drive, CD drive, hard drives, and network. NOTE: System boot is not supported from an external device attached to a SAS or SCSI adapter. See support.dell.com for the latest support information about booting from external devices. Determines the order in which the system searches the hard drives during system startup. The selections depend on the hard drives installed in your system. Determines the emulation type for a USB flash drive. Hard disk allows the USB flash drive to act as a hard drive. Floppy allows the USB flash drive to act as a removal diskette drive. Auto automatically chooses an emulation type. If this field is enabled and the system has failed to boot, the system will reattempt to boot after 30 seconds. See "Integrated Devices Screen" on page 28. Displays a screen to change the IRQ assigned to each of the integrated devices on the PCI bus, and any installed expansion card that requires an IRQ. Options are On with Console Redirection via COM2, and Off. Displays a screen to configure the system password and setup password features. See "System Security Screen" on page 29, "Using the System Password" on page 30, and "Using the Setup Password" on page 32 for more information. Determines whether your system starts up with the NumLock mode activated on 101- or 102-key keyboards (does not apply to 84-key keyboards). Enables or disables reporting of keyboard errors during the POST. Select Report for host systems that have keyboards attached. Select Do Not Report to suppress all error messages relating to the keyboard or keyboard controller during POST. This setting does not affect the operation of the keyboard itself if a keyboard is attached to the system.

Boot Sequence

Hard-Disk Drive Sequence USB Flash Drive Emulation Type (Auto default) Boot Sequence Retry Integrated Devices PCI IRQ Assignment Serial Communication (Off default) System Security

Keyboard NumLock (On default) Report Keyboard Errors (Report default)

26

Using the System Setup Program

Downloaded from www.Manualslib.com manuals search engine

Memory Information Screen
Table 2-3 lists the descriptions for the information fields that appear on the Memory Information screen.
Table 2-3. Memory Information Screen Option System Memory Size System Memory Type System Memory Speed Video Memory System Memory Testing Node Interleaving Description Displays the amount of system memory. Displays the type of system memory. Displays the system memory speed. Displays the amount of video memory. This option determines whether system memory tests are run at system boot. Options are Enabled and Disabled. If this field is enabled, memory interleaving is supported if a symmetric memory configuration is installed. If this field is set to disabled (the default), the system can support Non-Uniform Memory Architecture (NUMA) memory access. See "Memory Module Installation Guidelines" on page 46.

CPU Information Screen
Table 2-4 lists the options and descriptions for the information fields that appear on the CPU Information screen.
Table 2-4. Option 64-bit Core Speed Bus Speed Demand-Based Power Management (Disabled default) CPU Information Screen Description Specifies if the installed processor(s) support 64-bit extensions. Displays the clock speed of the processor(s). Displays the bus speed of the processor(s). Enables or disables demand-based power management. When enabled, the CPU Performance State tables will be reported to the operating system; when disabled, the CPU Performance State tables will not be reported to the operating system. If any of the CPUs do not support demand-based power management, the field will become read-only, and automatically set to Disabled. Displays the model number of the processor. A submenu displays the amount of level 2 cache and number of cores.

Processor X ID

Using the System Setup Program

27

Downloaded from www.Manualslib.com manuals search engine

Enabling AMD™ PowerNow!™ Technology

PowerNow! technology controls your system’s processor performance automatically, dynamically adjusting the operating frequency and voltage according to the task at hand. When an application does not require full performance, significant amounts of power can be saved. Performance is designed to still be responsive, with maximum processor performance being delivered when required, and automatic power savings when possible. (PowerNow! support is dependent on the operating system and version used on your system.) To enable the PowerNow! feature, run the System Setup Program and enable the Demand-Based Power Management option on the CPU Information screen. Additionally, for Microsoft® Windows® operating systems, you will need to install the PowerNow! driver to enable this feature. The driver is available on the Dell OpenManage Service and Diagnostic CD provided with your system and at support.dell.com.

Integrated Devices Screen
Table 2-5 lists the options and descriptions for the information fields that appear on the Integrated Devices screen.
Table 2-5. Option Embedded SATA Controller (Off default) Integrated Devices Screen Options Description Allows the integrated SATA controller to be set to Off or ATA mode.

IDE CD-ROM Controller Enables the integrated IDE controller. When set to Auto, each channel of the (Auto default) integrated IDE controller is enabled if IDE devices are attached to the channel and an external IDE controller is not detected. NOTE: This CD-ROM option will not appear on this menu screen if your system does not include this optional device. User-Accessible USB Ports Enables or disables the system's user-accessible ports. Options are All Ports On or (All Ports On default) All Ports Off. Disabling the USB ports makes system resources available for other devices. Embedded Gb NIC1 (Enabled with PXE default) MAC Address Embedded Gb NIC2 (Enabled without PXE default) MAC Address Enables or disables the system's integrated NIC1. Options are Enabled without PXE, Enabled with PXE, and Disabled. PXE support allows the system to boot from the network. Changes take effect after the system reboots. Displays the MAC address for NIC1. This field does not have user-selectable settings. Enables or disables the system's integrated NIC2. Options are Enabled without PXE, Enabled with PXE, and Disabled. PXE support allows the system to boot from the network. Changes take effect after the system reboots. Displays the MAC address for NIC2. This field does not have user-selectable settings.

28

Using the System Setup Program

Downloaded from www.Manualslib.com manuals search engine

System Security Screen
Table 2-6 lists the options and descriptions for the information fields that appear on the System Security screen.
Table 2-6. Option System Password System Security Screen Options Description Displays the current status of your system's password security feature and allows you to assign and verify a new system password. NOTE: See "Using the System Password" on page 30 for instructions on assigning a system password and using or changing an existing system password. Restricts access to the System Setup program in the same way that you restrict access to your system using the system password feature. NOTE: See "Using the Setup Password" on page 32 for instructions on assigning a setup password and using or changing an existing setup password. Setting the Setup Password option to Enabled prevents the system password from being changed or disabled at system start-up. To lock the system password, assign a setup password in the Setup Password option and then change the Password Status option to Locked. In this state, you cannot change the system password using the System Password option and cannot be disabled at system start-up by pressing . To unlock the system password, enter the setup password in the Setup Password field and then change the Password Status option to Unlocked. In this state, you can disable the system password at system start-up by pressing and then change the password using the System Password option. Power Button Turns system's power off and on. • If you turn off the system using the power button and the system is running an ACPI-compliant operating system, the system can perform an orderly shutdown before power is turned off. • If the system is not running an ACPI-compliant operating system, power is turned off immediately after the power button is pressed. The button is enabled in the System Setup program. When disabled, the button can only turn on system power. NOTE: You can still turn on the system by using the power button, even if the Power Button option is set to Disabled. NMI Button

Setup Password

Password Status

NOTICE: Use the NMI button only if directed to do so by qualified support personnel or by the operating system's documentation. Pressing this button halts the operating system and displays a diagnostic screen.
Enables or disables the NMI feature.

Using the System Setup Program

29

Downloaded from www.Manualslib.com manuals search engine

Table 2-6. Option

System Security Screen Options (continued) Description Determines how the system reacts when power is restored to the system. If system is set to Last, the system returns to the last power state. On turns on the system after power is restored. When set to Off, the system remains off after power is restored.

AC Power Recovery (Last default)

Exit Screen
After you press to exit the System Setup program, the Exit screen displays the following options: • • • Save Changes and Exit Discard Changes and Exit Return to Setup

System and Setup Password Features
NOTICE: The password features provide a basic level of security for the data on your system. If your data requires more security, use additional forms of protection, such as data encryption programs. NOTICE: Anyone can access the data stored on your system if you leave the system running and unattended without having a system password assigned or if you leave your system unlocked so that someone can disable the password by changing a jumper setting. Your system is shipped to you without the system password feature enabled. If system security is a concern, operate your system only with system password protection. To change or delete an existing password, you must know the password (see "Deleting or Changing an Existing System Password" on page 32). If you forget your password, you cannot operate your system or change settings in the System Setup program until a trained service technician changes the password jumper setting to disable the passwords, and erases the existing passwords. This procedure is described in "Disabling a Forgotten Password" on page 90.

Using the System Password
After a system password is assigned, only those who know the password have full use of the system. When the System Password option is set to Enabled, the system prompts you for the system password after the system starts.
Assigning a System Password

Before you assign a system password, enter the System Setup program and check the System Password option.

30

Using the System Setup Program

Downloaded from www.Manualslib.com manuals search engine

When a system password is assigned, the setting shown for the System Password option is Enabled. If the setting shown for the Password Status is Unlocked, you can change the system password. If the Password Status option is Locked, you cannot change the system password. When the system password feature is disabled by a jumper setting, the system password is Disabled, and you cannot change or enter a new system password. When a system password is not assigned and the password jumper on the system board is in the enabled (default) position, the setting shown for the System Password option is Not Enabled and the Password Status field is Unlocked. To assign a system password: 1 Verify that the Password Status option is set to Unlocked. 2 Highlight the System Password option and press . 3 Type your new system password. You can use up to 32 characters in your password. As you press each character key (or the spacebar for a blank space), a placeholder appears in the field. The password assignment is not case-sensitive. However, certain key combinations are not valid. To erase a character when entering your password, press or the left-arrow key. NOTE: To escape from the field without assigning a system password, press to move to another field, or press at any time prior to completing step 5.

4 Press . 5 To confirm your password, type it a second time and press . The setting shown for the System Password changes to Enabled. Exit the System Setup program and begin using your system. 6 Either reboot your system now for your password protection to take effect or continue working. NOTE: Password protection does not take effect until you reboot the system.
Using Your System Password to Secure Your System

NOTE: If you have assigned a setup password (see "Using the Setup Password" on page 32"), the system accepts your setup password as an alternate system password. When the Password Status option is set to Unlocked, you have the option to leave the password security enabled or to disable the password security. To leave the password security enabled: 1 Turn on or reboot your system by pressing . 2 Type your password and press . To disable the password security: 1 Turn on or reboot your system by pressing . 2 Type your password and press .

Using the System Setup Program

31

Downloaded from www.Manualslib.com manuals search engine

When the Password Status option is set to Locked whenever you turn on your system or reboot your system by pressing , type your password and press at the prompt. After you type the correct system password and press , your system operates as usual. If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password. You have three attempts to enter the correct password. After the third unsuccessful attempt, the system displays an error message showing the number of unsuccessful attempts and that the system has halted and will shut down. This message can alert you to an unauthorized person attempting to use your system. Even after you shut down and restart the system, the error message continues to be displayed until the correct password is entered. NOTE: You can use the Password Status option in conjunction with the System Password and Setup Password options to further protect your system from unauthorized changes.
Deleting or Changing an Existing System Password

1 When prompted, press to disable the existing system password. If you are asked to enter your setup password, contact your network administrator. 2 Enter the System Setup program by pressing during POST. 3 Select the System Security screen field to verify that the Password Status option is set to Unlocked. 4 When prompted, type the system password. 5 Confirm that Not Enabled is displayed for the System Password option. If Not Enabled is displayed for the System Password option, the system password has been deleted. If Enabled is displayed for the System Password option, press the key combination to restart the system, and then repeat steps 2 through 5.

Using the Setup Password
Read the information in the following sections to assign or change your setup password.
Assigning a Setup Password

You can assign (or change) a setup password only when the Setup Password option is set to Not Enabled. To assign a setup password, highlight the Setup Password option and press the or key. The system prompts you to enter and verify the password. If a character is illegal for password use, the system beeps. NOTE: The setup password can be the same as the system password. If the two passwords are different, the setup password can be used as an alternate system password. However, the system password cannot be used in place of the setup password. You can use up to 32 characters in your password. As you press each character key (or the spacebar for a blank space), a placeholder appears in the field.

32

Using the System Setup Program

Downloaded from www.Manualslib.com manuals search engine

The password assignment is not case-sensitive. However, certain key combinations are not valid. If you enter one of these combinations, the system beeps. To erase a character when entering your password, press or the left-arrow key. After you verify the password, the Setup Password setting changes to Enabled. The next time you enter the System Setup program, the system prompts you for the setup password. A change to the Setup Password option becomes effective immediately (restarting the system is not required).
Operating With a Setup Password Enabled

If Setup Password is set to Enabled, you must enter the correct setup password before you can modify most of the System Setup options. When you start the System Setup program, the program prompts you to enter a password. If you do not enter the correct password in three attempts, the system lets you view, but not modify, the System Setup screens—with the following exception: If System Password is not set to Enabled and is not locked through the Password Status option, you can assign a system password. NOTE: You can use the Password Status option in conjunction with the Setup Password option to protect the system password from unauthorized changes.
Deleting or Changing an Existing Setup Password

1 Enter the System Setup program and select the System Security option. 2 Highlight the Setup Password option, press to access the setup password window, and press twice to clear the existing setup password. The setting changes to Not Enabled. 3 If you want to assign a new setup password, perform the steps in "Assigning a Setup Password" on page 32.

Disabling a Forgotten Password
See "Disabling a Forgotten Password" on page 90.

Baseboard Management Controller Configuration
The Baseboard Management Controller (BMC) enables configuring, monitoring, and recovery of systems remotely. BMC provides the following features: • • • • Uses the system’s integrated NIC Fault logging and SNMP alerting Access to system event log and sensor status Control of system functions including power on and off

Using the System Setup Program

33

Downloaded from www.Manualslib.com manuals search engine

• •

Support is independent of the system’s power or operating state Provides text console redirection for system setup, text-based utilities, and operating system consoles NOTE: To remotely access the BMC through the integrated NIC, you must connect the network connection to integrated NIC1.

For additional information on using BMC, see the documentation for the BMC and systems management applications.

Entering the BMC Setup Module
1 Turn on or restart your system. 2 Press when prompted after POST. If your operating system begins to load before you press , allow the system to finish booting, and then restart your system and try again.

BMC Setup Module Options
For information about the BMC Setup Module options and how to configure the emergency management port (EMP), see the BMC User’s Guide.

34

Using the System Setup Program

Downloaded from www.Manualslib.com manuals search engine

Installing System Components
This section describes how to install the following system components: • • • • • • • • • • • • • • • • Front bezel System cover Cooling shroud Cooling fan modules Power supply Expansion cards System memory Processors Optical drive Hard drives Boot drive SAS controller card System battery Risers Control panel assembly System board

Recommended Tools
You may need the following items to perform the procedures in this section: • • • • • Key to the system keylock #2 Phillips screwdriver T10 Torx driver Small flat-blade screwdriver Wrist grounding strap

Installing System Components

35

Downloaded from www.Manualslib.com manuals search engine

Inside the System
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. CAUTION: The memory modules can become extremely hot during normal operation. Allow the modules sufficient time to cool before handling. In Figure 3-1, the bezel, system cover, and cooling shroud are removed to provide an interior view of the system.
Figure 3-1. Inside the System 2

1 3

4

5

8

6

7 1 4 7 power supply memory modules (8) optical drive (optional) 2 5 8 cooling shroud heatsink/microprocessor (2) 3.5-inch hard drive bays (2) 3 6 expansion card cooling fan modules (2)

Several hardware options, such as the microprocessors and memory, are installed directly on the system board. The riser card accommodates one half-length expansion card. For more information, see "Expansion Cards" on page 44.

36

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

The system provides space for one optional slimline optical drive. For more information, see "Installing the Optical Drive in the System" on page 54. The hard-drive bays provide space for one or two 3.5-inch hard drives. The hard drives connect to the SATA controller or the system board, or an optional SAS controller card. For more information, see "Hard Drives" on page 55. During an installation or troubleshooting procedure, you may be required to change a jumper setting. For more information, see "Jumpers and Connectors" on page 89. NOTE: There are no hot-pluggable components inside this system.

Removing and Replacing the Front Bezel
The system front panel is enclosed by an optional bezel. To access the optional optical drive, you must remove the bezel. NOTE: You do not need to remove the front bezel to remove the system cover and access internal components. 1 Using the system key, unlock the bezel. 2 Press the tab at the left end of the bezel. 3 Rotate the left end of the bezel away from the system to release the right end of the bezel. 4 Pull the bezel away from the system. See Figure 3-2.
Figure 3-2. Removing the Bezel

1

2 1 key lock 2 bezel

To replace the front bezel, perform the preceding steps in reverse.

Installing System Components

37

Downloaded from www.Manualslib.com manuals search engine

Opening and Closing the System
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. CAUTION: Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the system by yourself. CAUTION: The memory modules can become extremely hot during normal operation. Allow the modules sufficient time to cool before handling.

Opening the System
To upgrade or troubleshoot the system, remove the system cover to gain access to internal components. 1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals. 2 Rotate the latch release lock on the latch in a counter clockwise direction to the unlocked position. See Figure 3-3. 3 Lift up on the latch on top of the system and slide the cover back. See Figure 3-3. 4 Grasp the cover on both sides and carefully lift the cover away from the system.
Figure 3-3. Removing the Cover 1

2

3

1

latch Installing System Components

2

latch release lock

3

J hooks

38

Downloaded from www.Manualslib.com manuals search engine

Closing the System
1 Lift up the latch on the cover. 2 Align the cover with the left and right edges of the system and offset it slightly towards the back of the system, so that the pins on the inner edge of the cover are aligned with the chassis J hooks. See Figure 3-3. 3 Lower the cover onto the chassis and close the latch. 4 Rotate the latch release lock in a clockwise direction to secure the cover.

Cooling Shroud
The cooling shroud covers the memory modules (DIMMs) and the processor(s).

Removing the Cooling Shroud
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. CAUTION: The memory modules are hot to the touch for some time after the system has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components on the memory module. NOTICE: Never operate your system with the cooling shroud removed. Overheating of the system can develop quickly resulting in a shutdown of the system and the loss of data. 1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals. 2 Open the system. See "Opening and Closing the System" on page 38. 3 Grasp the shroud by the blue lift points and carefully lift the shroud straight up and away from the system. See Figure 3-4.

Installing System Components

39

Downloaded from www.Manualslib.com manuals search engine

Figure 3-4. Cooling Shroud 1

2

1

cooling shroud

2

locator pins (6)

Replacing the Cooling Shroud
1 To install the cooling shroud, align the edges of the shroud with the six locator pins on the system board. See Figure 3-4. 2 Lower the shroud into place over the system board. 3 Close the system. See "Opening and Closing the System" on page 38.

Cooling Fan Modules
This system contains two cooling fan modules, each comprised of two dual-rotor fans.

Removing a Cooling Fan Module
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. 1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals. 2 Open the system. See "Opening and Closing the System" on page 38. 3 Remove the cooling shroud. See "Removing the Cooling Shroud" on page 39. 40
Installing System Components

Downloaded from www.Manualslib.com manuals search engine

4 Unplug the fan module power connector from the system board. See Figure 3-5. 5 Remove the screw from the fan module retention plate and remove the retention plate from the chassis. 6 Lift the fan module straight up from the chassis.
Figure 3-5. Removing and Installing a Cooling Fan Module 2 3

1

4

1 4

fan module retention plates (2) 2 cooling fan modules (2)

retention plate screw (2)

3

fan power cable

Replacing a Cooling Fan Module
1 With the fan module label facing upwards and the arrow on the fan module pointing towards the back of the system, place the fan module into the chassis. See Figure 3-5. 2 Reinstall the fan module retention plate. The four pins on the plate fit into the corresponding holes in the fan modules. 3 Secure the retention plate with the Phillips screw. 4 Connect the fan module power cable to the power connector on the system board. Ensure that the fan module power cable is resting in the notch in the chassis brace.
Installing System Components

41

Downloaded from www.Manualslib.com manuals search engine

5 Reinstall the cooling shroud. See "Replacing the Cooling Shroud" on page 40. 6 Close the system. See "Opening and Closing the System" on page 38.

Power Supply
Removing the Power Supply
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals. 2 Open the system. See "Opening and Closing the System" on page 38. 3 Disconnect the power cable from the power supply and remove the cable from the cable retention bracket. NOTICE: On a rack system, you may need to temporarily unlatch and lift the cable management arm. For information about the cable management arm, see the system’s Rack Installation Guide. 4 Disconnect the two power supply cables from the POWER1 and POWER2 connectors on the system board. See Figure 6-1. 5 If applicable, disconnect the hard drive power cables from the hard drive(s). 6 Remove the screw at the front of the power supply that secures the power supply to the chassis. See Figure 3-6. 7 Slide the power supply toward the front of the system and remove it from the system.

42

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

Figure 3-6. Removing and Installing a Power Supply 2 3

1

4

5 1 4 hard-drive power cables (2) POWER2 connector 2 5 retention screw POWER1 connector 3 power supply

Installing the Power Supply
NOTICE: On a rack system, you may need to temporarily unlatch and lift the cable management arm. For information about the cable management arm, see the system’s Rack Installation Guide. NOTICE: For more information about the power cable retention bracket, see Getting Started With Your System. 1 Lower the power supply into the system and slide the power supply into place against the back panel of the system. See Figure 3-6. 2 Reinstall the screw that secures the power supply to the chassis. 3 Connect the two power supply cables to the POWER1 and POWER2 connectors on the system board. See Figure 3-6. 4 If applicable, route the hard drive power cables through the oval opening in the chassis brace and connect them to the hard drives. 5 Close the system. See "Closing the System." 43

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

Expansion Cards
The system supports one half-length expansion card. Two different PCI riser board configurations are available: • • The PCIe riser has one x8-lane width PCIe expansion slot. The PCI-X riser has one 64-bit/133-MHz expansion slot.

Installing an Expansion Card
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. 1 Unpack the expansion card and prepare it for installation. For instructions, see the documentation accompanying the card. 2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 3 Open the system. See "Opening and Closing the System" on page 38. 4 If you are adding a new card, open the expansion-card latch and remove the filler bracket. See Figure 3-7. 5 Install the expansion card. See Figure 3-7. a b c

Position the expansion card so that the card-edge connector aligns with the expansion-card connector on the riser board. Insert the card-edge connector firmly into the expansion-card connector until the card is fully seated. When the card is seated in the connector, close the expansion-card latch. NOTICE: If you are installing a SAS RAID controller card, route the SAS cables though the oval opening in the chassis brace and connect the cables to the SAS connectors on the hard drives. Secure the cables to the clips on the edge of the cooling shroud.

6 Connect any cables to the expansion card.

See the documentation that came with the card for information about its cable connections. 7 Close the system. See "Opening and Closing the System" on page 38.

44

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

Figure 3-7. Installing an Expansion Card 3 2 4 5

1

1 4

riser board expansion card

2 5

expansion-card connector expansion-card latch

3

card-edge connector

Removing an Expansion Card
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. 1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 2 Open the system. See "Opening and Closing the System" on page 38. 3 Disconnect all cables from the card. 4 Remove the expansion card: a b

Open the expansion-card latch. See Figure 3-7. Grasp the expansion card by its edges, and carefully remove it from the expansion-card connector.

Installing System Components

45

Downloaded from www.Manualslib.com manuals search engine

5 If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch. NOTE: You must install a filler bracket over an empty expansion slot to maintain Federal Communications
Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.

6 Close the system. See "Opening and Closing the System" on page 38.

System Memory
You can upgrade your system memory to a maximum of 32 GB by installing 667-MHz registered DDR-II memory modules (DIMMs) in sets of 512-MB, 1-GB, 2-GB, or 4-GB modules. The eight memory sockets are located on the system board under the cooling shroud. Each processor has four memory channels, organized in sets of two channels. Your system hardware supports Non-Uniform Memory Architecture (NUMA) if two processors are installed. Each processor has its own memory controller and local memory for reduced access times, but it can also access memory from another processor. This architecture improves system performance if an operating system is installed that supports this feature. NOTICE: To enable NUMA, run the System Setup program and disable the Node Interleaving option. See "Using the System Setup Program" on page 23.

Memory Module Installation Guidelines
To ensure optimal performance of your system, observe the following guidelines when configuring your system memory. • • Memory modules must be installed in pairs, beginning with DIMM1 and DIMM2 (processor 1), and DIMM5 and DIMM6 (processor 2). The memory modules must be identical in speed and technology. The DIMMs in each pair must be the same size.

Sample Memory Configurations
Dual-Processor Memory Configurations

You can use the following configurations in a dual-processor system.

46

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

Table 3-1. Dual-Processor Memory Configurations Total System Memory 2 GB 4 GB 4 GB 6 GB 8 GB 8 GB 12 GB 16 GB 24 GB 32 GB CPU 1 DIMM1 512 MB 512 MB 1 GB 1 GB 1 GB 2 GB 2 GB 2 GB 4 GB 4 GB DIMM2 512 MB 512 MB 1 GB 1 GB 1 GB 2 GB 2 GB 2 GB 4 GB 4 GB 1 GB 2 GB 2 GB 4 GB 1 GB 2 GB 2 GB 4 GB 512 MB 1 GB 512 MB 1 GB 512 MB 512 MB DIMM3 DIMM4 DIMM5 512 MB 512 MB 1 GB 1 GB 1 GB 2 GB 2 GB 2 GB 4 GB 4 GB DIMM6 512 MB 512 MB 1 GB 1 GB 1 GB 2 GB 2 GB 2 GB 4 GB 4 GB 1 GB 2 GB 2 GB 4 GB 1 GB 2 GB 2 GB 4 GB 512 MB 1 GB 512 MB 1 GB 512 MB 512 MB CPU2 DIMM7 DIMM8

Single-Processor Memory Configurations

You can use the following configurations in a single-processor system.
Table 3-2. Single-Processor Memory Configurations Total System Memory 1 GB 2 GB 2 GB 3 GB 4 GB 4 GB 6 GB 8 GB 12 GB 16 GB CPU 1 DIMM1 512 MB 512 MB 1 GB 1 GB 1 GB 2 GB 2 GB 2 GB 4 GB 4 GB DIMM2 512 MB 512 MB 1 GB 1 GB 1 GB 2 GB 2 GB 2 GB 4 GB 4 GB 1 GB 2 GB 2 GB 4 GB 1 GB 2 GB 2 GB 4 GB 512 MB 1 GB 512 MB 1 GB 512 MB 512 MB DIMM3 DIMM4

Installing System Components

47

Downloaded from www.Manualslib.com manuals search engine

Non-Optimal Memory Configurations
System performance can be affected if your memory configuration does not conform to the preceding installation guidelines. Your system may issue an error message during startup stating that your memory configuration is non-optimal.

Installing Memory Modules
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. CAUTION: The memory modules are hot to the touch for some time after the system has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components on the memory module. 1 Open the system. See "Opening and Closing the System" on page 38. 2 Remove the cooling shroud. See "Removing the Cooling Shroud" on page 39. 3 Locate the memory module sockets. See Figure 6-2. 4 Press the ejectors on the memory module socket down and out, as shown in Figure 3-8, to allow the memory module to be inserted into the socket. 5 Handle each memory module only on either card edge, ensuring not to touch the middle of the memory module.
Figure 3-8. Installing and Removing a Memory Module 1

2

3

1

memory module

2

memory module socket ejectors (2)

3

alignment key

48

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

6 Align the memory module's edge connector with the alignment key of the memory module socket, and insert the memory module in the socket. NOTE: The memory module socket has an alignment key that allows you to install the memory module in the socket in only one way.

7 Press down on the memory module with your thumbs while pulling up on the ejectors with your index fingers to lock the memory module into the socket. When the memory module is properly seated in the socket, the ejectors on the memory module socket align with the ejectors on the other sockets that have memory modules installed. 8 Repeat step 3 through step 7 of this procedure to install the remaining memory modules. See "DualProcessor Memory Configurations" on page 46 or "Single-Processor Memory Configurations" on page 47 for supported memory configurations. 9 Replace the cooling shroud. See "Replacing the Cooling Shroud" on page 40. 10 Close the system. See "Opening and Closing the System" on page 38. 11 Restart the system, press when prompted to enter the System Setup program, and check the System Memory setting on the main System Setup screen. The system should have already changed the value to reflect the newly installed memory. 12 If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 1 through step 11 of this procedure, checking to ensure that the memory modules are firmly seated in their sockets. 13 Run the system memory test in the system diagnostics. See "Running the System Diagnostics" on page 85.

Removing Memory Modules
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. CAUTION: The memory modules are hot to the touch for some time after the system has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components on the memory module. 1 Open the system. See "Opening and Closing the System" on page 38. 2 Remove the cooling shroud. See "Removing the Cooling Shroud" on page 39. 3 Locate the memory module sockets. See Figure 6-2. 4 Press down and out on the ejectors on each end of the socket until the memory module pops out of the socket. See Figure 3-8. Handle each memory module only on either card edge, ensuring not to touch the middle of the memory module.

Installing System Components

49

Downloaded from www.Manualslib.com manuals search engine

5 Replace the cooling shroud. See "Replacing the Cooling Shroud" on page 40. 6 Close the system. See "Opening and Closing the System" on page 38.

Processors
You can upgrade your processor(s) to take advantage of future options in speed and functionality. Each processor and its associated internal cache memory are contained in a land grid array (LGA) package that is installed in a ZIF socket on the system board.

Removing a Processor
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. 1 Prior to upgrading your system, download and install the latest system BIOS version on support.dell.com. 2 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 3 Open the system. See "Opening and Closing the System" on page 38. 4 Remove the cooling shroud. See "Removing the Cooling Shroud" on page 39. NOTICE: When you remove the heat sink, the possibility exists that the processor might adhere to the heat sink and be removed from the socket. It is recommended that you remove the heat sink while the processor is warm. NOTICE: Never remove the heat sink from a processor unless you intend to remove the processor. The heat sink is necessary to maintain proper thermal conditions. NOTICE: The processor and heat sink can become extremely hot. Be sure the processor has had sufficient time to cool before handling. 5 Use a Phillips-head screwdriver to loosen the two retention screws on the heat sink. See Figure 3-9.

50

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

Figure 3-9. Installing and Removing the Heat Sink 1 2

3

1

heat sink

2

heat-sink retention screw (2)

3

thermal grease protective cover

6 Wait 30 seconds for the heat sink to loosen from the processor. 7 If the heat sink has not separated from the processor, carefully rotate the heat sink in a clockwise, then counterclockwise, direction until it releases from the processor. Do not pry the heat sink from the processor. 8 Lift the heat sink off of the processor and set the heat sink on the work surface so it rests on the ends of the retention screws. 9 Use a clean lint-free cloth to remove any thermal grease from the surface of the processor shield. 10 Pull the socket-release lever 90 degrees upward until the processor is released from the socket. See Figure 3-10.

Installing System Components

51

Downloaded from www.Manualslib.com manuals search engine

Figure 3-10.

Installing and Removing the Processor 2 1 3

4

5 6 1 4 processor shield processor 2 5 socket cover (remove before adding second processor) ZIF socket 3 6 socket-release lever socket key (2)

11 Open the processor shield and then lift the processor out of the socket. Leave the release lever up so that the socket is ready for the new processor. NOTICE: Be careful not to bend any of the pins on the LGA socket when removing the processor. Bending the pins can permanently damage the socket and system board.

Installing a Processor
1 Unpack the new processor. 2 Align the processor with the socket keys on the ZIF socket. See Figure 3-10. 3 If you are adding a second processor to an empty socket, perform the following steps: a b c

Remove the protective cover from the processor socket. See Figure 3-10. Pull the socket-release lever 90 degrees upward. See Figure 3-10. Lift the processor shield. See Figure 3-10.

52

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

4 Install the processor in the socket. NOTICE: Positioning the processor incorrectly can permanently damage the system board or the processor when you turn the system on. a b

If the release lever on the processor socket is not fully open, move it to that position. With the processor and the socket keys aligned, set the processor lightly in the socket.

NOTICE: Do not use force to seat the processor. When the processor is positioned correctly, it fits easily into the socket. c d

Close the processor shield. See Figure 3-10. Rotate the socket release lever back down until it snaps into place, securing the processor. See Figure 3-10. NOTE: If you did not receive a replacement heat sink, use the heat sink that you removed in step 8.

5 Install the heat sink. a If you receive a heat sink and pre-applied thermal grease with your processor kit, remove the protective sheet from the thermal grease layer on top of the heat sink. See Figure 3-9. If you did not receive a replacement heat sink with your processor kit, do the following: • • Using a clean lint-free cloth, remove the existing thermal grease from the heat sink you removed in step 8. Open the grease packet included with your processor kit and apply thermal grease evenly to the top of the processor.

b c

Place the heat sink onto the processor. See Figure 3-9. Tighten the two heat-sink retention screws. See Figure 3-9.

6 Close the system. See "Closing the System" on page 39. As the system boots, it detects the presence of the new processor and automatically changes the system configuration information in the System Setup program. 7 Press to enter the System Setup program, and check that the processor information matches the new system configuration. See "Using the System Setup Program" on page 23 for instructions about using the System Setup program. 8 Run the system diagnostics to verify that the new processor operates correctly. See "Running the System Diagnostics" on page 85 for information about running the diagnostics.

Installing System Components

53

Downloaded from www.Manualslib.com manuals search engine

Optical Drive
The optional slimline optical drive is mounted on a tray that slides into the front panel. NOTE: DVD devices are data only.

Removing the Optical Drive from the System
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet. 2 If applicable, remove the optional bezel. See "Removing and Replacing the Front Bezel" on page 37. 3 Open the system. See "Opening and Closing the System" on page 38. 4 Disconnect the optical-drive cable from the back of the drive. See Figure 3-11. 5 To remove the optical drive tray, lift the blue tray release tab and slide the drive tray out of the system. See Figure 3-11.

Installing the Optical Drive in the System
1 Align the optical drive tray with its opening in the front panel. 2 Slide in the drive tray until the release tab snaps into place. See Figure 3-11. 3 Connect the optical-drive cable from the back of the drive. See Figure 3-11. 4 Close the system. See "Opening and Closing the System" on page 38. 5 If applicable, replace the bezel. See "Removing and Replacing the Front Bezel" on page 37. 6 Reconnect your system and peripherals to their electrical outlets, and turn on the system.

54

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

Figure 3-11.

Removing and Installing the Optical Drive 3 4

5

2

6 1

1 4

drive tray interposer board retention tabs (2)

2 5

optical drive interposer board

3 6

tray release tab optical-drive cable

Removing the Optical Drive from the Drive Tray
1 Remove the interposer board from the drive by deflecting the tab at each end of the board. 2 To remove the drive from the tray, push outward on the left retention tab at the back of the tray so as to bend the tray wall out slightly and then pull up on the left side of the drive to disengage. To install a new drive in the tray, fit the drive into the tray, then fit the interposer board onto the back of the drive.

Hard Drives
This subsection describes how to install and configure SAS or SATA hard drives in the system's two internal hard-drive bays.

Installing System Components

55

Downloaded from www.Manualslib.com manuals search engine

Optional SAS RAID Controller
If you install the optional SAS RAID controller card, you can install two SAS or SATA hard drives and configure them for RAID 0 or RAID 1 operation. • • See "Expansion Cards" on page 44 for information on installing the optional SAS RAID controller card. See the RAID controller card documentation for information about the RAID configuration utility.

Before You Begin
You may need to use different programs than those provided with the operating system to partition and format SAS or SATA hard drives. NOTICE: Do not turn off or reboot your system while the drive is being formatted. Doing so can cause a drive failure. When you format a high-capacity hard drive, allow enough time for the formatting to be completed. Long format times for these drives are normal.

Installing a Hard Drive
1 If you are replacing an existing hard drive, disconnect the data and power cables from the back of the drive. See Figure 3-12. 2 To remove the drive carrier from the system, press inwards on the release tabs on each side of the carrier and lift the carrier from the system. See Figure 3-12. 3 If you are replacing an existing hard drive, deflect the sides of the carrier outward and separate the hard drive from the carrier. 4 To install the new hard drive in the carrier, fit the left edge of the drive into the carrier, then lower the right edge of the drive into the carrier until the pins fit into the corresponding holes in the drive. See Figure 3-12. 5 Reinstall the drive carrier into the system. 6 Connect the data cable to the back of the drive. 7 Connect the other end of the cable to the drive controller: • If you are connecting the drive to the optional SAS controller card, route the SAS data cable though the oval opening in the chassis brace and connect the cable to the data connector on the controller card. Secure the data cable to the clips on the edge of the cooling shroud. If you are connecting the drive to the SATA controller on the system board, route the SATA data cable though the oval opening in the chassis brace and connect the cable to SATA connector SATA A or SATA B. See Figure 6-2.



8 Connect the power cable to the back of the drive. See Figure 3-12.

56

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

Figure 3-12.

Installing a Hard-Drive 2 3

1

1

5

4 1 4 hard drive hard drive bay 1 2 5 drive carrier release tabs (2) hard drive bay 0 3 drive power and data cables

Configuring the Boot Device
If you plan to boot the system from a hard drive, the drive must be attached to the primary (or boot) controller. The device that the system boots from is determined by the boot order specified in the System Setup program. The System Setup program provides options that the system uses to scan for installed boot devices. See "Using the System Setup Program" on page 23 for information about the System Setup program.

Installing System Components

57

Downloaded from www.Manualslib.com manuals search engine

Expansion-Card Riser
Removing an Expansion-Card Riser
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 2 Open the system. See "Opening and Closing the System" on page 38. 3 If applicable, remove the expansion card from the riser. 4 Press the release latch on the riser board and lift the riser board straight up from the system board. See Figure 3-13.
Figure 3-13. Expansion-Card Riser Removal 2 1

4

3

1 4

riser board riser board alignment pins (2)

2

riser board release latch

3

riser board connector on system board

58

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

Installing an Expansion-Card Riser
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. 1 Align the riser board with the two alignment pins on the system board, then lower the board onto the pins. See Figure 3-13. 2 Press down on the riser board until the edge connector on the board is fully seated in the riser board connector on the system board. 3 If applicable, install the expansion card in the expansion-card slot. 4 Close the system. See "Opening and Closing the System" on page 38. 5 Reconnect your system and peripherals to their electrical outlets, and turn on the system.

System Battery
The system battery is a 3.0-volt (V), coin-cell battery.

Replacing the System Battery
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. CAUTION: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions. See your System Information Guide for additional information. 1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 2 Open the system. See "Opening and Closing the System" on page 38. 3 To improve access to the battery, disconnect the power cable from the POWER1 connector on the system board. See Figure 3-6. 4 Locate the battery socket. See Figure 6-2. NOTICE: If you pry the battery out of its socket with a blunt object, be careful not to touch the system board with the object. Ensure that the object is inserted between the battery and the socket before you attempt to pry out the battery. Otherwise, you may damage the system board by prying off the socket or by breaking circuit traces on the system board. NOTICE: To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery.

Installing System Components

59

Downloaded from www.Manualslib.com manuals search engine

5 Remove the system battery. a b

Support the battery connector by pressing down firmly on the positive side of the connector. While supporting the battery connector, press the battery toward the positive side of the connector and pry it up out of the securing tabs at the negative side of the connector.
Replacing the System Battery 1 2

Figure 3-14.

3 1 positive side of battery connector 2 system battery 3 negative side of battery connector

NOTICE: To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery.

6 Install the new system battery. a b c

Support the battery connector by pressing down firmly on the positive side of the connector. Hold the battery with the "+" facing up, and slide it under the securing tabs at the positive side of the connector. Press the battery straight down into the connector until it snaps into place.

7 If you disconnected the power cable from connector POWER1 in step 3, reconnect the power cable now. 8 Close the system. See "Opening and Closing the System" on page 38. 9 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. 10 Enter the System Setup program to confirm that the battery is operating properly. See "Using the System Setup Program" on page 23. 11 Enter the correct time and date in the System Setup program's Time and Date fields. 12 Exit the System Setup program. 13 To test the newly installed battery, turn off the system and disconnect it from the electrical outlet for at least an hour. 60

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

14 After an hour, reconnect the system to its electrical outlet and turn it on. 15 Enter the System Setup program and if the time and date are still incorrect, see "Getting Help" on page 95 for instructions on obtaining technical assistance.

Control Panel Assembly (Service-Only Procedure)
Removing the Control Panel
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 2 Open the system. See "Opening and Closing the System" on page 38. 3 Disconnect the control panel cable from the control panel board. See Figure 3-15. NOTICE: Do not pull on the cable to unseat the connector. Doing so can damage the cable. a b

Squeeze the metal tabs on the ends of the cable connector. Gently work the connector out of the socket.

4 Remove the two screws securing the control panel board, and remove the board. See Figure 3-15.

Installing System Components

61

Downloaded from www.Manualslib.com manuals search engine

Figure 3-15.

Control Panel Removal and Installation 3 1 2

3

4

1 4

control panel cable tabs (3)

2

control-panel circuit board securing screws (2)

3

control panel circuit board

Installing the Control Panel
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. 5 Place the new control panel board in the system and secure it with the two Phillips screws. See Figure 3-15. The front edge of the board fits under the three L-shaped tabs on the chassis. 6 Connect the control panel cable to the control panel board. 7 Close the system. See "Opening and Closing the System" on page 38. 8 Reconnect the system to the power source and turn on the system and attached peripherals. 62
Installing System Components

Downloaded from www.Manualslib.com manuals search engine

System Board (Service-Only Procedure)
Removing the System Board
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge. 1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 2 Open the system. See "Opening and Closing the System" on page 38. 3 Disconnect any cables from the system board back panel. 4 Remove the cooling shroud. See "Removing the Cooling Shroud" on page 39. 5 Remove the expansion-card riser from the system board. See "Removing an Expansion-Card Riser" on page 58. 6 Disconnect the two fan module power cables from the system board. See Figure 3-5. 7 Remove the power supply. See "Removing the Power Supply" on page 42. 8 If applicable, disconnect the optical drive cable from the system board. See Figure 6-2. NOTICE: Do not pull on the cable to unseat the connector. Doing so can damage the cable. a b

Squeeze the metal tabs on the ends of the cable connector. Gently work the connector out of the socket.

9 Disconnect the control panel cable from the system board. See Figure 6-2. NOTICE: Do not pull on the cable to unseat the connector. Doing so can damage the cable. a b

Squeeze the metal tabs on the ends of the cable connector. Gently work the connector out of the socket. Pull the system-board release pin. See Figure 3-16. While pulling the release pin, slide the system-board tray toward the front of the chassis. Lift up the system-board tray and remove it from the chassis.

10 Remove the system board: a b c

CAUTION: The memory modules and processor heat sink are hot to the touch for some time after the system has been powered down. Allow time for these components to cool before handling them. Handle the memory modules by the card edges and avoid touching the components on the memory module. NOTE: While removing the memory modules, record the memory module socket locations to ensure proper installation. 11 Remove the memory modules. See "Removing Memory Modules" on page 49. 12 Remove the heatsink(s) and microprocessor(s). See "Removing a Processor" on page 50.

Installing System Components

63

Downloaded from www.Manualslib.com manuals search engine

Figure 3-16.

System Board Removal 1

2

1 2

1

system board release pin

2

system board attached to system-board tray

Installing a System Board
1 Install the heatsink(s) and microprocessor(s). See "Installing a Processor" on page 52 2 Install the memory modules in their original locations. See "Installing Memory Modules" on page 48. 3 Lower the system-board tray into the system until the tray sits flat on the bottom of the chassis. 4 Slide the system-board tray toward the back of the chassis until the system board release pin locks into position. 5 Connect the control panel cable to the system board. See Figure 6-2. 6 If applicable, connect the optical drive cable to the system board. See Figure 6-2. 7 Reinstall the power supply. See "Installing the Power Supply" on page 43. 8 Replace the riser board. See "Installing an Expansion-Card Riser" on page 59. 9 Replace any expansion card(s). See "Installing an Expansion Card" on page 44. 10 Reconnect the two fan module power cables to the system board. See "Removing and Installing a Cooling Fan Module" on page 41. 11 Replace the cooling shroud. See "Replacing the Cooling Shroud" on page 40. 64
Installing System Components

Downloaded from www.Manualslib.com manuals search engine

12 Close the system. See "Opening and Closing the System" on page 38. 13 Connect the external cables to the system. 14 Reconnect the system to the power source and turn on the system and attached peripherals.

Installing System Components

65

Downloaded from www.Manualslib.com manuals search engine

66

Installing System Components

Downloaded from www.Manualslib.com manuals search engine

Troubleshooting Your System
Safety First—For You and Your System
To perform certain procedures in this document, you must remove the system cover and work inside the system. While working inside the system, do not attempt to service the system except as explained in this guide and elsewhere in your system documentation. CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

Start-Up Routine
Look and listen during the system's start-up routine for the indications described in Table 1-1.
Table 4-1. Start-Up Routine Indications Look/listen for: A status code displayed by the diagnostic indicator lights on the system front panel. An error message displayed on the monitor. Alert messages from the systems management software. The monitor's power indicator. The keyboard indicators. The USB CD drive activity indicator. The CD drive activity indicator. The hard-drive activity indicator. An unfamiliar constant scraping or grinding sound when you access a drive. Action See "Diagnostics Indicator Codes" on page 14. See "System Messages" on page 16. See the systems management software documentation. See "Troubleshooting the Video Subsystem" on page 69. See "Troubleshooting the Keyboard" on page 70. See "Troubleshooting a USB Device" on page 71. See "Troubleshooting an Optical Drive" on page 78. See "Troubleshooting a Hard Drive" on page 78. See "Getting Help" on page 95.

Troubleshooting Your System

67

Downloaded from www.Manualslib.com manuals search engine

Checking Basic Power Problems
1 If the power indicator on the system front panel or power supply does not indicate that power is available to the system, ensure that the power cable is securely connected to the power supply. 2 If the system is connected to a PDU or UPS, turn the PDU or UPS off and then on. 3 If the PDU or UPS is not receiving power, plug it into another electrical outlet. If it still is not receiving power, try another PDU or UPS. 4 Reconnect the system to the electrical outlet and turn on the system. 5 If the system still is not working properly, see "Troubleshooting the Power Supply" on page 74.

Checking the Equipment
This section provides troubleshooting procedures for external devices attached to the system, such as the monitor, keyboard, or mouse. Before you perform any of the procedures, see "Troubleshooting External Connections" on page 69.

Troubleshooting IRQ Assignment Conflicts
Most PCI devices can share an IRQ with another device, but they cannot use an IRQ simultaneously. To avoid this type of conflict, see the documentation for each PCI device for specific IRQ requirements. Table 4-2 lists the IRQ assignments.
Table 4-2. IRQ Line IRQ0 IRQ1 IRQ2 IRQ3 IRQ4 IRQ5 IRQ6 IRQ7 IRQ8 IRQ9 IRQ10 IRQ11 IRQ12 IRQ Assignment Defaults Assignment System timer Keyboard controller Interrupt controller 1 to enable IRQ8 through IRQ15 Available Serial port 1 (COM1 and COM3) Available Reserved Reserved Real-time clock ACPI functions (used for power management) Available Available Available

68

Troubleshooting Your System

Downloaded from www.Manualslib.com manuals search engine

Table 4-2. IRQ Line IRQ13 IRQ14 IRQ15

IRQ Assignment Defaults (continued) Assignment Math coprocessor IDE CD drive controller Available

Troubleshooting External Connections
Loose or improperly connected cables are the most likely source of problems for the system, monitor, and other peripherals (such as a printer, keyboard, mouse, or other external device). Ensure that all external cables are securely attached to the external connectors on your system. See "Front-Panel Features and Indicators" on page 11 and "Back-Panel Features and Indicators" on page 13 for the front- and back-panel connectors on your system.

Troubleshooting the Video Subsystem
Problem

• •

Monitor is not working properly. Video memory is faulty.

Action

1 Check the system and power connections to the monitor. 2 Determine whether the system has an expansion card with a video output connector. In this system configuration, the monitor cable should normally be connected to the connector on the expansion card, not to the system’s integrated video connector. To verify that the monitor is connected to the correct video connector, turn off the system and wait for 1 minute, then connect the monitor to the other video connector and turn the system on again. 3 Determine whether the system has monitors attached to both the front and rear video connectors. The system supports only one monitor attached to either the front or rear video connector. When a monitor is connected to the front panel, the back-panel video connector is disabled. If two monitors are attached to the system, disconnect one monitor. If the problem is not resolved, continue to the next step. 4 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. If the tests run successfully, the problem is not related to video hardware. If the tests fail, see "Getting Help" on page 95.

Troubleshooting Your System

69

Downloaded from www.Manualslib.com manuals search engine

Troubleshooting the Keyboard
Problem

• •

System message indicates a problem with the keyboard Keyboard is not functioning properly

Action

1 Enter the System Setup program and ensure that the USB ports are enabled. See "Using the System Setup Program" on page 23. 2 Examine the keyboard and its cable for signs of damage. 3 Swap the faulty keyboard with a working keyboard. If the problem is resolved, replace the faulty keyboard. See "Getting Help" on page 95. 4 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. If the problem is not resolved, see "Getting Help" on page 95.

Troubleshooting the Mouse
Problem

• •

System message indicates a problem with the mouse. Mouse is not functioning properly.

Action

1 Enter the System Setup program and ensure that the USB ports are enabled. See "Using the System Setup Program" on page 23. 2 Examine the mouse and its cable for signs of damage. 3 Swap the faulty mouse with a working mouse. If the problem is resolved, replace the faulty mouse. See "Getting Help" on page 95. 4 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. If the test fails, see "Getting Help" on page 95.

Troubleshooting Basic I/O Functions
Problem

• •

Error message indicates a problem with a serial port. Device connected to a serial port is not operating properly.

70

Troubleshooting Your System

Downloaded from www.Manualslib.com manuals search engine

Action

1 Enter the System Setup program and ensure that the serial port is enabled, and the serial port/COM ports are configured appropriately for any applications you are using. See "Using the System Setup Program" on page 23. 2 If the problem is confined to a particular application, see the application documentation for specific port configuration requirements that the program may require. 3 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. If the tests run successfully but the problem persists, see "Troubleshooting a Serial I/O Device" on page 71.

Troubleshooting a Serial I/O Device
Problem



Device connected to the serial port is not operating properly.

Action

1 Turn off the system and any peripheral devices connected to the serial port. 2 Swap the serial interface cable with a working cable, and turn on the system and the serial device. If the problem is resolved, replace the interface cable. 3 Turn off the system and the serial device, and swap the device with a comparable device. 4 Turn on the system and the serial device. If the problem is resolved, replace the serial device. See "Getting Help" on page 95. If the problem persists, see "Getting Help" on page 95.

Troubleshooting a USB Device
Problem

• •

System message indicates a problem with a USB device. Device connected to a USB port is not operating properly.

Action

1 Enter the System Setup program, and ensure that the USB ports are enabled. See "Using the System Setup Program" on page 23. 2 Turn off the system and any USB devices. 3 Disconnect the USB devices, and connect the malfunctioning device to the other USB connector. 4 Turn on the system and the reconnected device. If the problem is resolved, the USB connector might be defective. See "Getting Help" on page 95.
Troubleshooting Your System

71

Downloaded from www.Manualslib.com manuals search engine

5 If possible, swap the interface cable with a working cable. If the problem is resolved, replace the interface cable. See "Getting Help" on page 95. 6 Turn off the system and the USB device, and swap the device with a comparable device. 7 Turn on the system and the USB device. If the problem is resolved, replace the USB device. See "Getting Help" on page 95. If the problem persists, see "Getting Help" on page 95.

Troubleshooting a NIC
Problem



NIC cannot communicate with network.

Action

1 Run the appropriate online diagnostic test. See "Running the System Diagnostics" on page 85. 2 Check the appropriate indicator on the NIC connector. See "NIC Indicator Codes" on page 14. • • • • If the link indicator does not light, check all cable connections. If the activity indicator does not light, the network driver files might be damaged or missing. Remove and reinstall the drivers if applicable. See the NIC documentation. Change the autonegotiation setting, if possible. Use another connector on the switch or hub.

If you are using a NIC card instead of an integrated NIC, see the documentation for the NIC card. 3 Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC documentation. 4 Enter the System Setup program and confirm that the NICs are enabled. See "Using the System Setup Program" on page 23. 5 Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed. See the network equipment documentation. 6 Ensure that all network cables are of the proper type and do not exceed the maximum length. See Network Cable Requirements in your Getting Started Guide.

Troubleshooting a Wet System
Problem

• • 72

Liquid spilled on the system. Excessive humidity.
Troubleshooting Your System

Downloaded from www.Manualslib.com manuals search engine

Action

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge. 1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 2 Open the system. See "Opening and Closing the System" on page 38. 3 Remove any expansion card installed in the system. See "Removing an Expansion Card" on page 45. 4 Let the system dry thoroughly for at least 24 hours. 5 Close the system. See "Opening and Closing the System" on page 38. 6 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. If the system does not start properly, see "Getting Help" on page 95. 7 If the system starts properly, shut down the system and reinstall any expansion card that you removed. See "Installing an Expansion Card" on page 44. 8 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. If the tests fail, see "Getting Help" on page 95.

Troubleshooting a Damaged System
Problem



System was dropped or damaged.

Action

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge. 1 Open the system. See "Opening and Closing the System" on page 38. 2 Ensure that the following components are properly installed: • • • • • Cooling shroud Expansion card and riser Processor(s) and heatsink(s) Memory modules Fans

3 Ensure that all cables are properly connected. 4 Close the system. See "Opening and Closing the System" on page 38.
Troubleshooting Your System

73

Downloaded from www.Manualslib.com manuals search engine

5 Run the system board tests in the system diagnostics. See "Running the System Diagnostics" on page 86. If the tests fail, see "Getting Help" on page 95.

Troubleshooting the System Battery
Problem

• • •

System message indicates a problem with the battery. System Setup program loses system configuration information. System date and time do not remain current. NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system configuration information. This situation is caused by a defective battery.

Action

1 Re-enter the time and date through the System Setup program. See "Using the System Setup Program" on page 23. 2 Turn off the system and disconnect it from the electrical outlet for at least one hour. 3 Reconnect the system to the electrical outlet and turn on the system. 4 Enter the System Setup program. If the date and time are not correct in the System Setup program, replace the battery. See "System Battery" on page 59. If the problem is not resolved by replacing the battery, see "Getting Help" on page 95. NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate normally except for the time kept in the System Setup program, the problem may be caused by software rather than by a defective battery.

Troubleshooting the Power Supply
Problem



Power button indicator is off.

Action

1 Ensure that the power supply is properly installed by reconnecting the power cables to the system board. See "Installing the Power Supply" on page 43. If the problem persists, continue to the next step.

74

Troubleshooting Your System

Downloaded from www.Manualslib.com manuals search engine

2 Replace the faulty power supply with a new power supply. See "Power Supply" on page 42. If the problem is not resolved, see ""Getting Help" on page 95."
Problem



Power button is not blinking green and the system does not power up.

Action

1 Ensure that the power cable is properly connected between the power supply and electrical outlet. 2 If you have a UPS, make sure that it is connected properly both to the power supply and to the electrical outlet. 3 Ensure that the power supply is properly installed by reconnecting the power cables to the system board. See "Installing the Power Supply" on page 43. 4 Replace the power supply with a new power supply. See "Power Supply" on page 42. 5 If the problem persists, see ""Getting Help" on page 95."

Troubleshooting System Cooling Problems
Problem



Systems management software issues a fan-related error message.

Action

Ensure that none of the following conditions exist: • • • • • System cover or cooling shroud is removed. Ambient temperature is too high. External airflow is obstructed. Cables inside the system obstruct airflow. A cooling fan has failed. See "Troubleshooting a Fan" on page 75.

Troubleshooting a Fan
Problem

• •

System-status indicator is amber. Systems management software issues a fan-related error message.

Troubleshooting Your System

75

Downloaded from www.Manualslib.com manuals search engine

Action

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge. 1 Run the appropriate diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. 2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 3 Open the system. See "Opening and Closing the System" on page 38. 4 Locate the faulty fan module indicated by the diagnostic software. For the identification number of each fan, see "Removing and Installing a Cooling Fan Module" on page 41. 5 Ensure that the faulty fan module’s power cable is firmly attached to the fan power connector on the system board. See "Cooling Fan Modules" on page 40. 6 If the problem is not resolved, install a new fan module. See "Cooling Fan Modules" on page 40. 7 Close the system. See "Opening and Closing the System" on page 38. 8 Run the appropriate diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. If the replacement fan module does not operate, see "Getting Help" on page 95.

Troubleshooting System Memory
Problem

• • •

Faulty memory module. Faulty system board. Diagnostic indicator code indicates a problem with system memory.

Action

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge. 1 If the system is operational, run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. If diagnostics indicates a fault, follow the corrective action(s) provided by the diagnostic program. If the problem is not resolved or if the system is not operational, proceed to step 2. 2 Turn off the system and attached peripherals, unplug the system from the power source and press the power button, and reconnect the system to power.

76

Troubleshooting Your System

Downloaded from www.Manualslib.com manuals search engine

3 Turn on the system and attached peripherals and, as the system boots, note the messages on the screen. If the amount of system memory detected during POST does not match the amount of memory installed, proceed to the next step. If an error message appears, go to step 12. 4 Enter the System Setup program and check the system memory setting. See "Using the System Setup Program" on page 23. If the amount of memory installed matches the system memory setting, go to step 12. 5 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 6 Open the system. See "Opening and Closing the System" on page 38. 7 Ensure that the memory banks are populated correctly. See "Memory Module Installation Guidelines" on page 46. If the memory modules are populated correctly, continue to the next step. 8 Reseat the memory modules in their sockets. See "Installing Memory Modules" on page 48. 9 Close the system. See "Opening and Closing the System" on page 38. 10 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. 11 Enter the System Setup program and check the system memory setting. See "Using the System Setup Program" on page 23. If the amount of memory installed still does not match the system memory setting, proceed to the next step. 12 Turn off the system and attached peripherals, and disconnect the system from its electrical outlet. 13 Open the system. See "Opening and Closing the System" on page 38. 14 If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module. Otherwise, swap the memory module in socket 1 with a module of the same type and capacity that is known to be good. See "Installing Memory Modules" on page 48. 15 Close the system. See "Opening and Closing the System" on page 38. 16 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. 17 As the system boots, observe any error message that appears and the diagnostic indicators on the front of the system. 18 If the memory problem is still indicated, repeat step 12 through step 17 for each memory module installed until the faulty memory module is replaced. If the problem persists after all memory modules have been checked, see "Getting Help" on page 95.

Troubleshooting Your System

77

Downloaded from www.Manualslib.com manuals search engine

Troubleshooting an Optical Drive
Problem

• •

System cannot read data from a CD or DVD in an optical drive. Optical drive indicator does not blink during boot. NOTE: DVD devices are data only.

Action

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge. 1 Try using a different CD or DVD that you know works properly. 2 Enter the System Setup program and ensure that the drive’s IDE controller is enabled. See "Using the System Setup Program" on page 23. 3 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. 4 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 5 Open the system. See "Opening and Closing the System" on page 38. 6 Ensure that the interface cable is securely connected to the optical drive. 7 Close the system. See "Opening and Closing the System" on page 38. 8 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. If the problem is not resolved, see "Getting Help" on page 95.

Troubleshooting a Hard Drive
Problem

• •

Device driver error. One or more hard drives not recognized by the system.

Action

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

78

Troubleshooting Your System

Downloaded from www.Manualslib.com manuals search engine

NOTICE: This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive. 1 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. Depending on the results of the diagnostics test, proceed as needed through the following steps. 2 If your system has a SAS RAID controller card, perform the following steps. a Restart the system and press to enter the RAID configuration utility program. See the documentation supplied with the RAID controller for information about the configuration utility.

b c

Ensure that the hard drive has been configured correctly for the RAID controller. Exit the configuration utility and allow the system to boot to the operating system.

3 If your system has a SAS controller card, ensure that the required device drivers are installed and are configured correctly. See the operating system documentation for more information. 4 Check the cable connections inside the system: a b c

Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. Open the system. See "Opening and Closing the System" on page 38. Verify that the cable connections between the hard drive(s) and the drive controller are correct, whether the connections are to the SATA connectors on the system board (see Figure 6-2) or a SAS expansion card. Verify that the drive cables are seated in their connectors. Close the system. See "Opening and Closing the System" on page 38. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

d e f

If the problem persists, see "Getting Help" on page 95.

Troubleshooting a SAS RAID Controller Card
NOTE: When troubleshooting a SAS RAID controller card, also see the documentation for your operating system and the controller card.
Problem

• •

Error message indicates a problem with the SAS RAID controller card. SAS RAID controller card performs incorrectly or not at all.

Troubleshooting Your System

79

Downloaded from www.Manualslib.com manuals search engine

Action

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge. 1 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. 2 Enter the System Setup program and ensure that the SAS RAID controller card is enabled and drivers are loaded. See "Using the System Setup Program" on page 23. 3 Restart the system and press to enter the SAS RAID controller configuration utility program. See the controller's documentation for information about configuration settings. 4 Check the configuration settings, make any necessary corrections, and restart the system. If the problem is not resolved, continue to the next step. 5 Turn off the system and attached peripherals, and disconnect the system from its electrical outlet. 6 Open the system. See "Opening and Closing the System" on page 38. 7 Ensure that the controller card is firmly seated in its connector. See "Expansion Cards" on page 44. 8 If you have a SAS RAID controller card, ensure that the memory module is properly installed. 9 Verify that the cable connections between the drives and the SAS controller card are correct. See "Installing a Hard Drive" on page 56. 10 Close the system. See "Opening and Closing the System" on page 38. 11 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. If the problem persists, see "Getting Help" on page 95.

Troubleshooting an Expansion Card
NOTE: When troubleshooting an expansion card, see the documentation for your operating system and the expansion card.
Problem

• •

Error message indicates a problem with an expansion card. Expansion card performs incorrectly or not at all.

80

Troubleshooting Your System

Downloaded from www.Manualslib.com manuals search engine

Action

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge. 1 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85. 2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 3 Open the system. See "Opening and Closing the System" on page 38. 4 Ensure that the riser board and expansion card are firmly seated in their connectors. See "Installing an Expansion Card" on page 44 and "Expansion-Card Riser" on page 58. 5 Close the system. See "Opening and Closing the System" on page 38. 6 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. If the problem persists, go to the next step. 7 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 8 Open the system. See "Opening and Closing the System" on page 38. 9 Remove the expansion card. 10 Close the system. See "Opening and Closing the System" on page 38. 11 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. 12 Run the appropriate online diagnostic test. If the tests fail, see "Getting Help" on page 95. 13 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 14 Open the system. See "Opening and Closing the System" on page 38. 15 Reinstall the expansion card. 16 Close the system. See "Opening and Closing the System" on page 38. 17 Run the appropriate diagnostic test. If the tests fail, see "Getting Help" on page 95.

Troubleshooting Your System

81

Downloaded from www.Manualslib.com manuals search engine

Troubleshooting the Microprocessors
Problem

• •

Error message indicates a processor problem. A heat sink is not installed for each processor.

Action

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge. 1 If possible, run the appropriate online diagnostics test. See "Using Dell PowerEdge Diagnostics" on page 85. 2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 3 Open the system. See "Opening and Closing the System" on page 38. 4 Ensure that each processor and heat sink are properly installed. See "Removing a Processor" on page 50. 5 Close the system. See "Opening and Closing the System" on page 38. 6 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. 7 Run the appropriate online diagnostic test. If the tests fail or the problem persists, continue to the next step. 8 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 9 Open the system. See "Opening and Closing the System" on page 38. 10 Remove processor 2, leaving only processor 1 installed. See "Removing a Processor" on page 50. If only one processor is installed, see "Getting Help" on page 95. 11 Close the system. See "Opening and Closing the System" on page 38. 12 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. 13 Run the appropriate online diagnostic test. If the tests complete successfully, go to step 19. 14 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 15 Open the system. See "Opening and Closing the System" on page 38. 16 Replace processor 1 with another processor of the same capacity. See "Removing a Processor" on page 50. 17 Close the system. See "Opening and Closing the System" on page 38.

82

Troubleshooting Your System

Downloaded from www.Manualslib.com manuals search engine

18 Run the appropriate online diagnostic test. If the tests complete successfully, replace processor 1. See "Getting Help" on page 95. 19 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 20 Open the system. See "Opening and Closing the System" on page 38. 21 Reinstall the processor that you removed in step 10. See "Removing a Processor" on page 50. 22 Close the system. See "Opening and Closing the System" on page 38. 23 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. If the problem persists, see "Getting Help" on page 95.

Troubleshooting Your System

83

Downloaded from www.Manualslib.com manuals search engine

84

Troubleshooting Your System

Downloaded from www.Manualslib.com manuals search engine

Running the System Diagnostics
If you experience a problem with your system, run the diagnostics before calling for technical assistance. The purpose of the diagnostics is to test your system's hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use diagnostics test results to help you solve the problem.

Using Dell PowerEdge Diagnostics
To assess a system problem, first use the online Dell™ PowerEdge™ Diagnostics. Dell PowerEdge Diagnostics is a suite of diagnostic programs, or test modules, that include diagnostic tests on chassis and storage components such as hard drives, physical memory, communications and printer ports, NICs, CMOS, and more. If you are unable to identify the problem using the PowerEdge Diagnostics, then use the system diagnostics. The files required to run PowerEdge Diagnostics for systems running supported Microsoft® Windows® and Linux operating systems are available at support.dell.com and on the CDs that came with your system. For information about using diagnostics, see the Dell PowerEdge Diagnostics User's Guide.

System Diagnostics Features
The system diagnostics provides a series of menus and options for particular device groups or devices. The system diagnostics menus and options allow you to: • • • • • • • • Run tests individually or collectively. Control the sequence of tests. Repeat tests. Display, print, or save test results. Temporarily suspend testing if an error is detected or terminate testing when a user-defined error limit is reached. View help messages that briefly describe each test and its parameters. View status messages that inform you if tests are completed successfully. View error messages that inform you of problems encountered during testing.

Running the System Diagnostics

85

Downloaded from www.Manualslib.com manuals search engine

When to Use the System Diagnostics
If a major component or device in the system does not operate properly, component failure may be indicated. As long as the microprocessor and the system's input/output devices (monitor, keyboard, and diskette drive) are functioning, you can use the system diagnostics to help identify the problem.

Running the System Diagnostics
The system diagnostics is run from the utility partition on your hard drive. NOTICE: Use the system diagnostics to test only your system. Using this program with other systems may cause invalid results or error messages. In addition, use only the program that came with your system (or an updated version of that program). 1 As the system boots, press during POST. 2 From the utility partition main menu, select Run System Diagnostics, or select Run Memory Diagnostics if you are troubleshooting memory. When you start the system diagnostics, a message is displayed stating that the diagnostics are initializing. Next, the Diagnostics menu appears. The menu allows you to run all or specific diagnostics tests or to exit the system diagnostics. NOTE: Before you read the rest of this section, start the system diagnostics so that you can see the utility on your screen. System Diagnostics Testing Options
Click the testing option in the Main Menu window. Table 5-1 provides a brief explanation of testing options.
Table 5-1. System Diagnostics Testing Options Function Performs a quick check of the system. This option runs device tests that do not require user interaction. Use this option to quickly identify the source of your problem. Performs a more thorough check of the system. This test can take an hour or longer. Tests a particular device. Displays test results.

Testing Option Express Test

Extended Test Custom Test Information

86

Running the System Diagnostics

Downloaded from www.Manualslib.com manuals search engine

Using the Custom Test Options
When you select Custom Test in the Main Menu window, the Customize window appears and allows you to select the device(s) to be tested, select specific options for testing, and view the test results.

Selecting Devices for Testing
The left side of the Customize window lists devices that can be tested. Devices are grouped by device type or by module, depending on the option you select. Click the (+) next to a device or module to view its components. Click (+) on any component to view the tests that are available. Clicking a device, rather than its components, selects all of the components of the device for testing.

Selecting Diagnostics Options
Use the Diagnostics Options area to select how you want to test a device. You can set the following options: • • • • • Non-Interactive Tests Only — When checked, runs only tests that require no user intervention. Quick Tests Only — When checked, runs only the quick tests on the device. Extended tests will not run when you select this option. Show Ending Timestamp — When checked, time stamps the test log. Test Iterations — Selects the number of times the test is run. Log output file pathname — When checked, enables you to specify where the test log file is saved.

Viewing Information and Results
The tabs in the Customize window provide information about the test and the test results. The following tabs are available: • • • • • Results — Displays the test that ran and the result. Errors — Displays any errors that occurred during the test. Help — Displays information about the currently selected device, component, or test. Configuration — Displays basic configuration information about the currently selected device. Parameters — If applicable, displays parameters that you can set for the test.

Running the System Diagnostics

87

Downloaded from www.Manualslib.com manuals search engine

88

Running the System Diagnostics

Downloaded from www.Manualslib.com manuals search engine

Jumpers and Connectors
This section provides specific information about the system jumpers. It also provides some basic information on jumpers and switches and describes the connectors on the various boards in the system.

System Board Jumpers
Figure 6-1 shows the location of the configuration jumpers on the system board. Table 6-1 lists the jumper settings.
Figure 6-1. System Board Jumpers

Jumpers and Connectors

89

Downloaded from www.Manualslib.com manuals search engine

Table 6-1.

System Board Jumper Settings Setting Description

Jumper

1

PWRD_EN

(default)

The password feature is enabled. The password feature is disabled.

2

NVRM_CLR

(default)

The configuration settings are retained at system boot. The configuration settings are cleared at the next system boot. (If the configuration settings become corrupted to the point where the system will not boot, install the jumper and boot the system. Remove the jumper before restoring the configuration information.)

NOTE: For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 121.

Disabling a Forgotten Password
The system's software security features include a system password and a setup password, which are discussed in detail in "Using the System Setup Program" on page 23. The password jumper enables these password features or disables them and clears any password(s) currently in use. NOTICE: See "Protecting Against Electrostatic Discharge" in the safety instructions in your Product Information
Guide.

1 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 2 Open the system. See "Opening and Closing the System" on page 38. 3 Lift up the memory module shroud. 4 Remove the jumper plug from the password jumper. See Figure 6-1 to locate the password jumper on the system board. 5 Close the system. 6 Reconnect your system and peripherals to their electrical outlets, and turn on the system. The existing passwords are not disabled (erased) until the system boots with the password jumper plug removed. However, before you assign a new system and/or setup password, you must install the jumper plug. NOTE: If you assign a new system and/or setup password with the jumper plug still removed, the system disables the new password(s) the next time it boots.

90

Jumpers and Connectors

Downloaded from www.Manualslib.com manuals search engine

7 Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 8 Open the system. See "Opening and Closing the System" on page 38. 9 Install the jumper plug on the password jumper. 10 Lower the memory module shroud. 11 Close the system. 12 Reconnect your system and peripherals to their electrical outlets, and turn on the system. 13 Assign a new system and/or setup password. To assign a new password using the System Setup program, see "Assigning a System Password" on page 30.

Jumpers and Connectors

91

Downloaded from www.Manualslib.com manuals search engine

System Board Connectors
See Figure 6-2 and Table 6-2 for the location and description of system board connectors.
Figure 6-2. System Board Connectors 1 2 3 4 5 6

7 8 22 21 20 19 18 17 16 15 14 13 12 11 9 10

92

Jumpers and Connectors

Downloaded from www.Manualslib.com manuals search engine

Table 6-2.

System Board Connectors Description Riser board connector Memory module connector, slot 5 Memory module connector, slot 6 Memory module connector, slot 7 Memory module connector, slot 8 Microprocessor 2 connector Memory module connector, slot 1 Memory module connector, slot 2 Memory module connector, slot 3 Memory module connector, slot 4 System cooling fan module 2 connector Microprocessor 1 connector System cooling fan module 1 connector Optical drive connector Control panel connector Power connector SATA B connector SATA A connector Connector for the 3.0-V battery Power connector NVRAM clear jumper Password enable jumper

Connector 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 RISER DIMM5 DIMM6 DIMM7 DIMM8 CPU2 DIMM1 DIMM2 DIMM3 DIMM4 FAN_MOD2 CPU1 FAN_MOD1 IDE CTRL_PNL POWER1 SATA_B SATA_A BATTERY POWER2 NVRM_CLR PWRD_EN

NOTE: For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 121.

Jumpers and Connectors

93

Downloaded from www.Manualslib.com manuals search engine

Riser Boards
This system supports a riser board with one PCIe expansion slot (Figure 6-3), or a riser board with one PCI-X expansion slot (Figure 6-4).
Figure 6-3. PCIe Riser Board

Figure 6-4. PCI-X Riser Board

94

Jumpers and Connectors

Downloaded from www.Manualslib.com manuals search engine

Getting Help
Technical Assistance
If you need assistance with a technical problem, perform the following steps: 1 Complete the procedures in "Troubleshooting Your System" on page 67. 2 Run the system diagnostics and record any information provided. 3 Make a copy of the Diagnostics Checklist, and fill it out. 4 Use Dell's extensive suite of online services available at Dell Support at support.dell.com for help with installation and troubleshooting procedures. For more information, see "Online Services" on page 95. 5 If the preceding steps have not resolved the problem, call Dell for technical assistance. NOTE: Call technical support from a phone near or at the system so that technical support can assist you with any necessary procedures. NOTE: Dell’s Express Service Code system may not be available in all countries. When prompted by Dell's automated telephone system, enter your Express Service Code to route the call directly to the proper support personnel. If you do not have an Express Service Code, open the Dell Accessories folder, double-click the Express Service Code icon, and follow the directions. For instructions on using the technical support service, see "Technical Support Service" on page 96 and "Before You Call" on page 98. NOTE: Some of the following services are not always available in all locations outside the continental U.S. Call your local Dell representative for information on availability.

Online Services
You can access Dell Support at support.dell.com. Select your region on the WELCOME TO DELL SUPPORT page, and fill in the requested details to access help tools and information. You can contact Dell electronically using the following addresses: • World Wide Web www.dell.com/ www.dell.com/ap/ (Asian/Pacific countries only) www.dell.com/jp (Japan only)

Getting Help

95

Downloaded from www.Manualslib.com manuals search engine

www.euro.dell.com (Europe only) www.dell.com/la (Latin American countries) www.dell.ca (Canada only) • Anonymous file transfer protocol (FTP) ftp.dell.com/ Log in as user:anonymous, and use your e-mail address as your password. • Electronic Support Service support@us.dell.com apsupport@dell.com (Asian/Pacific countries only) support.jp.dell.com (Japan only) support.euro.dell.com (Europe only) • Electronic Quote Service apmarketing@dell.com (Asian/Pacific countries only) sales_canada@dell.com (Canada only)

AutoTech Service
Dell's automated technical support service—AutoTech—provides recorded answers to the questions most frequently asked by Dell customers about their portable and desktop computer systems. When you call AutoTech, use your touch-tone telephone to select the subjects that correspond to your questions. The AutoTech service is available 24 hours a day, 7 days a week. You can also access this service through the technical support service. See the contact information for your region.

Automated Order-Status Service
To check on the status of any Dell™ products that you have ordered, you can go to support.dell.com, or you can call the automated order-status service. A recording prompts you for the information needed to locate and report on your order. See the contact information for your region.

Technical Support Service
Dell's technical support service is available 24 hours a day, 7 days a week, to answer your questions about Dell hardware. Our technical support staff use computer-based diagnostics to provide fast, accurate answers. To contact Dell's technical support service, see "Before You Call" on page 98 and then see the contact information for your region.

96

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Dell Enterprise Training and Certification
Dell Enterprise Training and Certification is available; see www.dell.com/training for more information. This service may not be offered in all locations.

Problems With Your Order
If you have a problem with your order, such as missing parts, wrong parts, or incorrect billing, contact Dell for customer assistance. Have your invoice or packing slip available when you call. See the contact information for your region.

Product Information
If you need information about additional products available from Dell, or if you would like to place an order, visit the Dell website at www.dell.com. For the telephone number to call to speak to a sales specialist, see the contact information for your region.

Returning Items for Warranty Repair or Credit
Prepare all items being returned, whether for repair or credit, as follows: 1 Call Dell to obtain a Return Material Authorization Number, and write it clearly and prominently on the outside of the box. For the telephone number to call, see the contact information for your region. 2 Include a copy of the invoice and a letter describing the reason for the return. 3 Include a copy of any diagnostic information (including the Diagnostics Checklist) indicating the tests you have run and any error messages reported by the system diagnostics. 4 Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diskettes, and guides) if the return is for credit. 5 Pack the equipment to be returned in the original (or equivalent) packing materials. You are responsible for paying shipping expenses. You are also responsible for insuring any product returned, and you assume the risk of loss during shipment to Dell. Collect-on-delivery (C.O.D.) packages are not accepted. Returns that are missing any of the preceding requirements will be refused at our receiving dock and returned to you.

Getting Help

97

Downloaded from www.Manualslib.com manuals search engine

Before You Call
NOTE: Have your Express Service Code ready when you call. The code helps Dell's automated-support telephone system direct your call more efficiently.

Remember to fill out the Diagnostics Checklist. If possible, turn on your system before you call Dell for technical assistance and call from a telephone at or near the computer. You may be asked to type some commands at the keyboard, relay detailed information during operations, or try other troubleshooting steps possible only at the computer system itself. Ensure that the system documentation is available. CAUTION: Before servicing any components inside your computer, see your Product Information Guide for important safety information.

98

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Diagnostics Checklist Name: Date: Address: Phone number: Service Tag (bar code on the back of the computer): Express Service Code: Return Material Authorization Number (if provided by Dell support technician): Operating system and version: Peripherals:

Expansion cards: Are you connected to a network? Yes No Network, version, and network card: Programs and versions:

See your operating system documentation to determine the contents of the system’s start-up files. If possible, print each file. Otherwise, record the contents of each file before calling Dell. Description of problem and troubleshooting procedures you performed:

Getting Help

99

Downloaded from www.Manualslib.com manuals search engine

Contacting Dell
To contact Dell electronically, you can access the following websites: • • www.dell.com support.dell.com (support) NOTE: Toll-free numbers are for use within the country for which they are listed. NOTE: In certain countries, support specific to Dell XPS™ portable computers is available at a separate telephone number listed for participating countries. If you do not see a telephone number listed that is specific for XPS portable computers, you may contact Dell through the support number listed and your call will be routed appropriately. When you need to contact Dell, use the electronic addresses, telephone numbers, and codes provided in the following table. If you need assistance in determining which codes to use, contact a local or an international operator. NOTE: The contact information provided was deemed correct at the time that this document went to print and is subject to change.

For specific web addresses for your country, find the appropriate country section in the table below.

Country (City) International Access Code Country Code City Code Anguilla

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: www.dell.com.ai E-mail: la-techsupport@dell.com General Support toll-free: 800-335-0031

Antigua and Barbuda

Website: www.dell.com.ag E-mail: la-techsupport@dell.com General Support 1-800-805-5924 0800-105

Aomen

Technical Support (Dell™ Dimension™, Dell Inspiron™, Dell OptiPlex™, Dell Latitude™, and Dell Precision™) Technical Support (servers and storage)

0800-105

100

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Argentina (Buenos Aires) International Access Code: 00 Country Code: 54 City Code: 11

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: www.dell.com.ar E-mail: la-techsupport@dell.com E-mail for desktop and portable computers: la-techsupport@dell.com E-mail for servers and EMC® storage products: la_enterprise@dell.com Customer Care Technical Support Technical Support Services Sales toll-free: 0-800-444-0730 toll-free: 0-800-444-0733 toll-free: 0-800-444-0724 0-810-444-3355

Aruba

Website: www.dell.com.aw E-mail: la-techsupport@dell.com General Support toll-free: 800-1578

Australia (Sydney) Country Code: 61 City Code: 2 Austria (Vienna) International Access Code: 900 Country Code: 43 City Code: 1

Website: support.ap.dell.com Technical Support (XPS) General Support Website: support.euro.dell.com E-mail: tech_support_central_europe@dell.com Home/Small Business Sales Home/Small Business Fax Home/Small Business Customer Care Preferred Accounts/Corporate Customer Care Support for XPS Home/Small Business Support for all other Dell computers Preferred Accounts/Corporate Support Switchboard 0820 240 530 00 0820 240 530 49 0820 240 530 14 0820 240 530 16 0820 240 530 81 0820 240 530 17 0820 240 530 17 0820 240 530 00 toll-free: 1300 790 877 13DELL-133355

International Access Code: 0011 E-mail: support.ap.dell.com/contactus

Bahamas

Website: www.dell.com.bs E-mail: la-techsupport@dell.com General Support toll-free: 1-866-874-3038

Getting Help

101

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Barbados

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: www.dell.com/bb E-mail: la-techsupport@dell.com General Support 1-800-534-3142 02 481 92 96 02 481 92 88 02 481 92 95 02 713 15 65 02 481 91 00 02 481 92 99 02 481 91 00

Belgium (Brussels) International Access Code: 00 Country Code: 32 City Code: 2

Website: support.euro.dell.com Tech Support for XPS Tech Support for all other Dell computers Tech Support Fax Customer Care Corporate Sales Fax Switchboard

Bermuda

Website: www.dell.com/bm E-mail: la-techsupport@dell.com General Support 1-877-890-0751

Bolivia

Website: www.dell.com/bo E-mail: la-techsupport@dell.com General Support toll-free: 800-10-0238

Brazil International Access Code: 00 Country Code: 55 City Code: 51

Website: www.dell.com/br E-mail: BR-TechSupport@dell.com Customer Care and Tech Support Technical Support Fax Customer Care Fax Sales 0800 90 3355 51 2104 5470 51 2104 5480 0800 722 3498 toll-free: 1-866-278-6820 604 633 4966 604 633 4888 604 633 4955

British Virgin Islands Brunei Country Code: 673

General Support Technical Support (Penang, Malaysia) Customer Care (Penang, Malaysia) Transaction Sales (Penang, Malaysia)

102

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Canada (North York, Ontario) International Access Code: 011

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Online Order Status: www.dell.ca/ostatus Website: support.ca.dell.com AutoTech (automated Hardware and Warranty Support) Customer Service (Home/Home Office) Customer Service (small/med./large business, government) Customer Service (printers, projectors, televisions, handhelds, digital jukebox, and wireless) Hardware Warranty Phone Support (XPS) Hardware Warranty Phone Support (Home/Home Office) Hardware Warranty Phone Support (small/med./large business, government) Hardware Warranty Phone Support (printers, projectors, televisions, handhelds, digital jukebox, and wireless) Sales (Home Sales/Small Business) Sales (med./large bus., government) Spare Parts Sales & Extended Service Sales toll-free: 1-800-247-9362 toll-free: 1-800-847-4096 toll-free: 1-800-387-5757 toll-free: 1-800-847-4096 toll-free: 1-866-398-8977 toll-free: 1-800-847-4096 toll-free: 1-800-387-5757 1-877-335-5767

toll-free: 1-800-387-5752 toll-free: 1-800-387-5755 1 866 440 3355 1-877-262-5415

Cayman Islands Chile (Santiago) Country Code: 56 City Code: 2

E-mail: la-techsupport@dell.com General Support Website: www.dell.com/cl E-mail: la-techsupport@dell.com Sales and Customer Support toll-free: 1230-020-4823

Getting Help

103

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code China (Xiamen) Country Code: 86 City Code: 592

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Technical Support website: support.dell.com.cn Technical Support E-mail: support.dell.com.cn/email Customer Care E-mail: customer_cn@dell.com Technical Support Fax Technical Support (XPS) Technical Support (Dimension and Inspiron) Technical Support (OptiPlex, Latitude, and Dell Precision) Technical Support (servers and storage) Technical Support (projectors, PDAs, switches, routers, and so on) Technical Support (printers) Customer Care Customer Care Fax Home and Small Business Preferred Accounts Division Large Corporate Accounts GCP Large Corporate Accounts Key Accounts Large Corporate Accounts North Large Corporate Accounts North Government and Education Large Corporate Accounts East Large Corporate Accounts East Government and Education Large Corporate Accounts Queue Team Large Corporate Accounts South Large Corporate Accounts West Large Corporate Accounts Spare Parts 592 818 1350 toll-free: 800 858 0540 toll-free: 800 858 2969 toll-free: 800 858 0950 toll-free: 800 858 0960 toll-free: 800 858 2920 toll-free: 800 858 2311 toll-free: 800 858 2060 592 818 1308 toll-free: 800 858 2222 toll-free: 800 858 2557 toll-free: 800 858 2055 toll-free: 800 858 2628 toll-free: 800 858 2999 toll-free: 800 858 2955 toll-free: 800 858 2020 toll-free: 800 858 2669 toll-free: 800 858 2572 toll-free: 800 858 2355 toll-free: 800 858 2811 toll-free: 800 858 2621

Colombia

Website: www.dell.com/cl E-mail: la-techsupport@dell.com General Support 01-800-915-4755

104

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Costa Rica

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: www.dell.com/cr E-mail: la-techsupport@dell.com General Support 0800-012-0231

Czech Republic (Prague) International Access Code: 00 Country Code: 420

Website: support.euro.dell.com E-mail: czech_dell@dell.com Technical Support Customer Care Fax Technical Fax Switchboard 22537 2727 22537 2707 22537 2714 22537 2728 22537 2711 7010 0074 7023 0182 7023 0184 3287 5505 3287 1200 3287 1201 3287 5000 3287 5001

Denmark (Copenhagen) International Access Code: 00 Country Code: 45

Website: support.euro.dell.com Technical Support for XPS Technical Support for all other Dell computers Customer Care (Relational) Home/Small Business Customer Care Switchboard (Relational) Switchboard Fax (Relational) Switchboard (Home/Small Business) Switchboard Fax (Home/Small Business)

Dominica

Website: www.dell.com/dm E-mail: la-techsupport@dell.com General Support toll-free: 1-866-278-6821

Dominican Republic

Website: www.dell.com/do E-mail: la-techsupport@dell.com General Support 1-800-156-1588

Ecuador

Website: www.dell.com/ec E-mail: la-techsupport@dell.com General Support (calling from Quito) General Support (calling from Guayaquil) toll-free: 999-119-877-655-3355 toll-free: 1800-999-119-877-6553355

Getting Help

105

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code El Salvador

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: www.dell.com/ec E-mail: la-techsupport@dell.com General Support 800-6132

Finland (Helsinki) International Access Code: 990 Country Code: 358 City Code: 9

Website: support.euro.dell.com E-mail: fi_support@dell.com Technical Support Customer Care Switchboard Sales under 500 employees Fax Sales over 500 employees Fax 0207 533 555 0207 533 538 0207 533 533 0207 533 540 0207 533 530 0207 533 533 0207 533 530

France (Paris) (Montpellier) International Access Code: 00 Country Code: 33 City Codes: (1) (4)

Website: support.euro.dell.com Home and Small Business Technical Support for XPS Technical Support for all other Dell computers Customer Care Switchboard Switchboard (calls from outside of France) Sales Fax Fax (calls from outside of France) Corporate Technical Support Customer Care Switchboard Sales Fax 0825 004 719 0825 338 339 01 55 94 71 00 01 55 94 71 00 01 55 94 71 01 0825 387 129 0825 387 270 0825 823 833 0825 004 700 04 99 75 40 00 0825 004 700 0825 004 701 04 99 75 40 01

106

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Germany (Frankfurt) International Access Code: 00 Country Code: 49 City Code: 69

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: support.euro.dell.com E-mail: tech_support_central_europe@dell.com Technical Support for XPS Technical Support for all other Dell computers Home/Small Business Customer Care Global Segment Customer Care Preferred Accounts Customer Care Large Accounts Customer Care Public Accounts Customer Care Switchboard 069 9792 7222 069 9792-7200 0180-5-224400 069 9792-7320 069 9792-7320 069 9792-7320 069 9792-7320 069 9792-7000 00800-44 14 95 18 00800-44 14 00 83 2108129810 2108129811 2108129800 2108129812 toll-free: 1-866-540-3355 1-800-999-0136 toll-free: 1-877-270-4609

Greece International Access Code: 00 Country Code: 30

Website: support.euro.dell.com Technical Support Gold Service Technical Support Switchboard Gold Service Switchboard Sales Fax

Grenada Guatemala Guyana

E-mail: la-techsupport@dell.com General Support E-mail: la-techsupport@dell.com General Support E-mail: la-techsupport@dell.com General Support

Getting Help

107

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Hong Kong International Access Code: 001 Country Code: 852

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: support.ap.dell.com Technical Support E-mail: support.dell.com.cn/email Technical Support (XPS) Technical Support (Dimension and Inspiron) Technical Support (OptiPlex, Latitude, and Dell Precision) Technical Support (servers and storage) Technical Support (projectors, PDAs, switches, routers, and so on) Customer Care Large Corporate Accounts Global Customer Programs Medium Business Division Home and Small Business Division 00852-3416 6923 00852-2969 3188 00852-2969 3191 00852-2969 3196 00852-3416 0906 00852-3416 0910 00852-3416 0907 00852-3416 0908 00852-3416 0912 00852-2969 3105

India

Website: support.ap.dell.com E-mail: india_support_desktop@dell.com india_support_notebook@dell.com india_support_Server@dell.com Technical Support (XPS computers) Technical Support (portables, desktops, servers, and storage) Sales (Large Corporate Accounts) Sales (Home and Small Business) 0802 506 8033 or toll-free: 1800 425 2066 1600338045 and 1600448046 1600 33 8044 1600 33 8046

108

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Ireland (Cherrywood) International Access Code: 00 Country Code: 353 City Code: 1

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: support.euro.dell.com E-mail: dell_direct_support@dell.com Sales Ireland Sales Dell Outlet Online Ordering HelpDesk Customer Care Home User Customer Care Small Business Customer Care Corporate Customer Care Technical Support Technical Support for XPS computers only Technical Support for all other Dell computers General Fax/Sales Fax Switchboard U.K. Customer Care (dial within U.K. only) Corporate Customer Care (dial within U.K. only) U.K. Sales (dial within U.K. only) 01 204 0103 01 204 4444 0870 906 0010 0870 907 4499 0870 907 4000 1850 200 722 1850 543 543 01 204 4014 01 204 4014 1850 200 982 01 204 4444 1850 200 778 1850 200 778

Italy (Milan) International Access Code: 00 Country Code: 39 City Code: 02

Website: support.euro.dell.com Home and Small Business Technical Support Customer Care Fax Switchboard Corporate Technical Support Customer Care Fax Switchboard 02 577 826 90 02 577 825 55 02 575 035 30 02 577 821 02 577 826 90 02 696 821 14 02 696 821 13 02 696 821 12

Getting Help

109

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Jamaica Japan (Kawasaki) International Access Code: 001 Country Code: 81 City Code: 44

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

E-mail: la-techsupport@dell.com General Support (dial from within Jamaica only) Website: support.jp.dell.com Technical Support (XPS) Technical Support outside of Japan (XPS) XPS Customer Care (if ordered items are missing or have been damaged during shipment) Technical Support (Dimension and Inspiron) Technical Support outside of Japan (Dimension and Inspiron) Technical Support (Dell Precision, OptiPlex, and Latitude) Technical Support outside of Japan (Dell Precision, OptiPlex, and Latitude) Technical Support (Dell PowerApp™, Dell PowerEdge™, Dell PowerConnect™, and Dell PowerVault™) Technical Support outside of Japan (PowerApp, PowerEdge, PowerConnect, and PowerVault) Technical Support (projectors, PDAs, printers, routers) Technical Support outside of Japan (projectors, PDAs, printers, routers) Faxbox Service 24-Hour Automated Order Status Service Customer Care Business Sales Division (up to 400 employees) Preferred Accounts Division Sales (over 400 employees) Public Sales (government agencies, educational institutions, and medical institutions) Global Segment Japan Individual User Switchboard toll-free: 0120-937-786 044-520-1235 044-556-4240 toll-free: 0120-198-226 81-44-520-1435 toll-free: 0120-198-433 81-44-556-3894 toll-free: 0120-198-498 1-800-440-9205

81-44-556-4162 toll-free: 0120-981-690 81-44-556-3468 044-556-3490 044-556-3801 044-556-4240 044-556-1465 044-556-3433 044-556-5963 044-556-3469 044-556-1760 044-556-4300

110

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Korea (Seoul) International Access Code: 001 Country Code: 82 City Code: 2 Support

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

E-mail: krsupport@dell.com toll-free: 080-200-3800 toll-free: 080-999-0283 toll-free: 080-200-3801 toll-free: 080-200-3600 2194-6202 2194-6000 512 728-4093 512 728-3619 512 728-3883 512 728-4397 512 728-4600 or 512 728-3772 Technical Support (XPS) Support (Dimension, PDA, Electronics, and Accessories) Sales Fax Switchboard

Latin America

Customer Technical Support (Austin, Texas, U.S.A.) Customer Service (Austin, Texas, U.S.A.) Fax (Technical Support and Customer Service) (Austin, Texas, U.S.A.) Sales (Austin, Texas, U.S.A.) SalesFax (Austin, Texas, U.S.A.)

Luxembourg International Access Code: 00 Country Code: 352

Website: support.euro.dell.com Support Home/Small Business Sales Corporate Sales Customer Care Fax 342 08 08 075 +32 (0)2 713 15 96 26 25 77 81 +32 (0)2 481 91 19 26 25 77 82 toll-free: 0800 105 34 160 910 29 693 115

Macao Country Code: 853

Technical Support Customer Service (Xiamen, China) Transaction Sales (Xiamen, China)

Getting Help

111

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Malaysia (Penang) International Access Code: 00 Country Code: 60 City Code: 4

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: support.ap.dell.com Technical Support (XPS) Technical Support (Dell Precision, OptiPlex, and Latitude) Technical Support (Dimension, Inspiron, and Electronics and Accessories) Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) Customer Care Transaction Sales Corporate Sales toll-free: 1800 885 784 toll-free: 1 800 880 193 toll-free: 1 800 881 306 toll-free: 1800 881 386 toll-free: 1800 881 306 (option 6) toll-free: 1 800 888 202 toll-free: 1 800 888 213 001-877-384-8979 or 001-877-269-3383 Sales Customer Service Main 50-81-8800 or 01-800-888-3355 001-877-384-8979 or 001-877-269-3383 50-81-8800 or 01-800-888-3355

Mexico International Access Code: 00 Country Code: 52

E-mail: la-techsupport@dell.com Customer Technical Support

Montserrat Netherlands Antilles

E-mail: la-techsupport@dell.com General Support E-mail: la-techsupport@dell.com General Support 001-800-882-1519 toll-free: 1-866-278-6822

112

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Netherlands (Amsterdam) International Access Code: 00 Country Code: 31 City Code: 20

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: support.euro.dell.com Technical Support for XPS Technical Support for all other Dell computers Technical Support Fax Home/Small Business Customer Care Relational Customer Care Home/Small Business Sales Relational Sales Home/Small Business Sales Fax Relational Sales Fax Switchboard Switchboard Fax 020 674 45 94 020 674 45 00 020 674 47 66 020 674 42 00 020 674 4325 020 674 55 00 020 674 50 00 020 674 47 75 020 674 47 50 020 674 50 00 020 674 47 50

New Zealand International Access Code: 00 Country Code: 64 Nicaragua Norway (Lysaker) International Access Code: 00 Country Code: 47

Website: support.ap.dell.com E-mail: support.ap.dell.com/contactus Technical Support (XPS) General Support E-mail: la-techsupport@dell.com General Support Website: support.euro.dell.com Technical Support for XPS Technical Support for all other Dell products Relational Customer Care Home/Small Business Customer Care Switchboard Fax Switchboard 815 35 043 671 16882 671 17575 23162298 671 16800 671 16865 011-800-507-1264 0800-50-669 001-800-220-1377 toll-free: 0800 335 540 0800 441 567

Panama Peru

E-mail: la-techsupport@dell.com General Support E-mail: la-techsupport@dell.com General Support

Getting Help

113

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Poland (Warsaw) International Access Code: 011 Country Code: 48 City Code: 22

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: support.euro.dell.com E-mail: pl_support_tech@dell.com Customer Service Phone Customer Care Sales Customer Service Fax Reception Desk Fax Switchboard 57 95 700 57 95 999 57 95 999 57 95 806 57 95 998 57 95 999 707200149 800 300 413 800 300 410 or 800 300 411 or 800 300 412 or 21 422 07 10 21 424 01 12 1-877-537-3355

Portugal International Access Code: 00 Country Code: 351

Website: support.euro.dell.com Technical Support Customer Care Sales Fax

Puerto Rico St. Kitts and Nevis

E-mail: la-techsupport@dell.com General Support Website: www.dell.com/kn E-mail: la-techsupport@dell.com General Support toll-free: 1-866-540-3355

St. Lucia

Website: www.dell.com/lc E-mail: la-techsupport@dell.com General Support toll-free: 1-866-464-4352

St. Vincent and the Grenadines Website: www.dell.com/vc E-mail: la-techsupport@dell.com General Support toll-free: 1-866-464-4353

114

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Singapore (Singapore) International Access Code: 005 Country Code: 65

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

NOTE: The phone numbers in this section should be called from within Singapore or Malaysia only. Website: support.ap.dell.com Technical Support (XPS) Technical Support (Dimension, Inspiron, and Electronics and Accessories) Technical Support (OptiPlex, Latitude, and Dell Precision) Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) Customer Care Transaction Sales Corporate Sales toll-free: 1800 394 7464 toll-free: 1 800 394 7430 toll-free: 1 800 394 7488 toll-free: 1 800 394 7478 toll-free: 1 800 394 7430 (option 6) toll-free: 1 800 394 7412 toll-free: 1 800 394 7419

Slovakia (Prague) International Access Code: 00 Country Code: 421

Website: support.euro.dell.com E-mail: czech_dell@dell.com Technical Support Customer Care Fax Tech Fax Switchboard (Sales) 02 5441 5727 420 22537 2707 02 5441 8328 02 5441 8328 02 5441 7585

South Africa (Johannesburg) International Access Code: 09/091 Country Code: 27 City Code: 11

Website: support.euro.dell.com E-mail: dell_za_support@dell.com Gold Queue Technical Support Customer Care Sales Fax Switchboard 011 709 7713 011 709 7710 011 709 7707 011 709 7700 011 706 0495 011 709 7700 604 633 4810

Southeast Asian and Pacific Countries

Technical Support, Customer Service, and Sales (Penang, Malaysia)

Getting Help

115

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Spain (Madrid) International Access Code: 00 Country Code: 34 City Code: 91

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: support.euro.dell.com Home and Small Business Technical Support Customer Care Sales Switchboard Fax Corporate Technical Support Customer Care Switchboard Fax 902 100 130 902 115 236 91 722 92 00 91 722 95 83 0771 340 340 08 590 05 199 08 590 05 642 08 587 70 527 020 140 14 44 08 590 05 594 08 590 05 185 902 100 130 902 118 540 902 118 541 902 118 541 902 118 539

Sweden (Upplands Vasby) International Access Code: 00 Country Code: 46 City Code: 8

Website: support.euro.dell.com Technical Support for XPS Technical Support for all other Dell products Relational Customer Care Home/Small Business Customer Care Employee Purchase Program (EPP) Support Technical Support Fax Sales

Switzerland (Geneva) International Access Code: 00 Country Code: 41 City Code: 22

Website: support.euro.dell.com E-mail: Tech_support_central_Europe@dell.com Technical Support for XPS Technical Support (Home and Small Business) for all other Dell products Technical Support (Corporate) Customer Care (Home and Small Business) Customer Care (Corporate) Fax Switchboard 0848 33 88 57 0844 811 411 0844 822 844 0848 802 202 0848 821 721 022 799 01 90 022 799 01 01

116

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code Taiwan International Access Code: 002 Country Code: 886

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: support.ap.dell.com E-mail: support.dell.com.cn/email Technical Support (XPS) Technical Support (OptiPlex, Latitude, Inspiron, Dimension, and Electronics and Accessories) Technical Support (servers and storage) Customer Care Transaction Sales Corporate Sales toll-free: 0080 186 3085 toll-free: 0080 186 1011 toll-free: 0080 160 1256 toll-free: 0080 160 1250 (option 5) toll-free: 0080 165 1228 toll-free: 0080 165 1227 toll-free: 1800 0060 07 toll-free: 1800 0600 09 toll-free: 1800 006 007 (option 7) toll-free: 1800 006 009 toll-free: 1800 006 006

Thailand International Access Code: 001 Country Code: 66

Website: support.ap.dell.com Technical Support (OptiPlex, Latitude, and Dell Precision) Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) Customer Care Corporate Sales Transaction Sales

Trinidad/Tobago

Website: www.dell.com/tt E-mail: la-techsupport@dell.com General Support toll-free: 1-888-799-5908

Turks and Caicos Islands

Website: www.dell.com/tc E-mail: la-techsupport@dell.com General Support toll-free: 1-877-441-4735

Getting Help

117

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code U.K. (Bracknell) International Access Code: 00 Country Code: 44 City Code: 1344

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Website: support.euro.dell.com E-mail: dell_direct_support@dell.com Customer Care website: support.euro.dell.com/uk/en/ECare/form/home.asp Sales Home and Small Business Sales Corporate/Public Sector Sales Customer Care Home and Small Business Customer Care Corporate Customer Care Preferred Accounts (500–5000 employees) Global Accounts Customer Care Central Government Customer Care Local Government & Education Customer Care Health Customer Care Technical Support Technical Support for XPS computers only Technical Support (Corporate/Preferred Accounts/PCA [1000+ employees]) Technical Support for all other products General Home and Small Business Fax 0870 907 4006 0870 366 4180 0870 908 0500 0870 353 0800 0870 906 0010 01344 373 185 0870 906 0010 01344 373 186 01344 373 193 01344 373 199 01344 373 194 0870 907 4000 01344 860 456

Uruguay

Website: www.dell.com/uy E-mail: la-techsupport@dell.com General Support toll-free: 000-413-598-2521

118

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code U.S.A. (Austin, Texas) International Access Code: 011 Country Code: 1

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers toll-free: 1-800-433-9014 toll-free: 1-800-247-9362 toll-free: 1-877-459-7298

Automated Order-Status Service AutoTech (portable and desktop computers) Hardware and Warranty Support (Dell TV, Printers, and Projectors) for Relationship customers Americas Consumer XPS Support Consumer (Home and Home Office) Support for all other Dell products Customer Service Employee Purchase Program (EPP) Customers Financial Services website: www.dellfinancialservices.com Financial Services (lease/loans) Financial Services (Dell Preferred Accounts [DPA]) Business Customer Service and Support Employee Purchase Program (EPP) Customers Support for printers, projectors, PDAs, and MP3 players Public (government, education, and healthcare) Customer Service and Support Employee Purchase Program (EPP) Customers Dell Sales Dell Outlet Store (Dell refurbished computers) Software and Peripherals Sales Spare Parts Sales Extended Service and Warranty Sales Fax Dell Services for the Deaf, Hard-of-Hearing, or Speech-Impaired

toll-free: 1-800-232-8544 toll-free: 1-800-624-9896 toll-free: 1-800-624-9897 toll-free: 1-800-695-8133

toll-free: 1-877-577-3355 toll-free: 1-800-283-2210 toll-free: 1-800-456-3355 toll-free: 1-800-695-8133 toll-free: 1-877-459-7298

toll-free: 1-800-456-3355 toll-free: 1-800-695-8133 toll-free: 1-800-289-3355 or toll-free: 1-800-879-3355 toll-free: 1-888-798-7561 toll-free: 1-800-671-3355 toll-free: 1-800-357-3355 toll-free: 1-800-247-4618 toll-free: 1-800-727-8320 toll-free: 1-877-DELLTTY (1-877-335-5889)

Getting Help

119

Downloaded from www.Manualslib.com manuals search engine

Country (City) International Access Code Country Code City Code U.S. Virgin Islands Venezuela

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

E-mail: la-techsupport@dell.com General Support Website: www.dell.com/ve E-mail: la-techsupport@dell.com General Support 0800-100-4752 toll-free: 1-877-702-4360

120

Getting Help

Downloaded from www.Manualslib.com manuals search engine

Glossary
This section defines or identifies technical terms, abbreviations, and acronyms used in your system documents.
BIOS — Basic input/output system. Your system’s BIOS contains programs stored on a flash memory chip. The BIOS controls the following: • Communications between the processor and peripheral devices • Miscellaneous functions, such as system messages bit — The smallest unit of information interpreted by your system. blade — A module that contains a processor, memory, and a hard drive. The modules are mounted into a chassis that includes power supplies and fans. BMC — Baseboard management controller. boot routine — A program that clears all memory, initializes devices, and loads the operating system when you start your system. Unless the operating system fails to respond, you can reboot (also called warm boot) your system by pressing . Otherwise, you must restart the system by pressing the reset button or by turning the system off and then back on. bootable diskette — A diskette that is used to start your system if the system will not boot from the hard drive. BTU — British thermal unit. bus — An information pathway between the components of a system. Your system contains an expansion bus that allows the processor to communicate with controllers for the peripheral devices connected to the system. Your system also contains an address bus and a data bus for communications between the processor and RAM. C — Celsius. cache — A fast storage area that keeps a copy of data or instructions for quick data retrieval. When a program makes a request to a disk drive for data that is in the cache, the disk-cache utility can retrieve the data from RAM faster than from the disk drive.

A — Ampere(s). AC — Alternating current. ACPI — Advanced Configuration and Power Interface. A standard interface for enabling the operating system to direct configuration and power management. ambient temperature — The temperature of the area or room where the system is located. ANSI — American National Standards Institute. The primary organization for developing technology standards in the U.S. application — Software designed to help you perform a specific task or series of tasks. Applications run from the operating system. ASCII — American Standard Code for Information Interchange. asset tag — An individual code assigned to a system, usually by an administrator, for security or tracking purposes. backup — A copy of a program or data file. As a precaution, back up your system’s hard drive on a regular basis. Before making a change to the configuration of your system, back up important start-up files from your operating system. backup battery — A battery that maintains system configuration, date, and time information in a special section of memory when the system is turned off.

Glossary

121

Downloaded from www.Manualslib.com manuals search engine

CD — Compact disc. CD drives use optical technology to read data from CDs. cm — Centimeter(s). cmos — Complementary metal-oxide semiconductor. component — As they relate to DMI, components include operating systems, computer systems, expansion cards, and peripherals that are compatible with DMI. Each component is made up of groups and attributes that are defined as relevant to that component. COMn — The device names for the serial ports on your system. control panel — The part of the system that contains indicators and controls, such as the power button and power indicator. controller — A chip that controls the transfer of data between the processor and memory or between the processor and a peripheral. conventional memory — The first 640 KB of RAM. Conventional memory is found in all systems. Unless they are specially designed, MS-DOS® programs are limited to running in conventional memory. coprocessor — A chip that relieves the system’s processor of specific processing tasks. A math coprocessor, for example, handles numeric processing. CPU — Central processing unit. See processor. DC — Direct current. DDR — Double-data rate. A technology in memory modules that potentially doubles the output. device driver — A program that allows the operating system or some other program to interface correctly with a peripheral. Some device drivers—such as network drivers—must be loaded from the config.sys file or as memory-resident programs (usually, from the autoexec.bat file). Others must load when you start the program for which they were designed. DHCP — Dynamic Host Configuration Protocol. A method of automatically assigning an IP address to a client system. diagnostics — A comprehensive set of tests for your system.

DIMM — Dual in-line memory module. See also memory module. DIN — Deutsche Industrie Norm. directory — Directories help keep related files organized on a disk in a hierarchical, “inverted tree” structure. Each disk has a “root” directory. Additional directories that branch off the root directory are called subdirectories. Subdirectories may contain additional directories branching off them. DMA — Direct memory access. A DMA channel allows certain types of data transfer between RAM and a device to bypass the processor. DMI — Desktop Management Interface. DMI enables the management of your system’s software and hardware by collecting information about the system’s components, such as the operating system, memory, peripherals, expansion cards, and asset tag. DNS — Domain Name System. A method of translating Internet domain names, such as www.dell.com, into IP addresses, such as 143.166.83.200. DRAM — Dynamic random-access memory. A system’s RAM is usually made up entirely of DRAM chips. DVD — Digital versatile disc. ECC — Error checking and correction. EEPROM — Electronically erasable programmable readonly memory. EMC — Electromagnetic compatibility. EMI — Electromagnetic interference. ESD — Electrostatic discharge. ESM — Embedded server management. expansion bus — Your system contains an expansion bus that allows the processor to communicate with controllers for peripherals, such as NICs. expansion card — An add-in card, such as a NIC or SCSI adapter, that plugs into an expansion-card connector on the system board. An expansion card adds some specialized function to the system by providing an interface between the expansion bus and a peripheral.

122

Glossary

Downloaded from www.Manualslib.com manuals search engine

expansion-card connector — A connector on the system board or riser board for plugging in an expansion card. F — Fahrenheit. FAT — File allocation table. The file system structure used by MS-DOS to organize and keep track of file storage. The Microsoft® Windows® operating systems can optionally use a FAT file system structure. FBD — Fully buffered DIMM. flash memory — A type of EEPROM chip that can be reprogrammed from a utility on diskette while still installed in a system; most EEPROM chips can only be rewritten with special programming equipment. format — To prepare a hard drive or diskette for storing files. An unconditional format deletes all data stored on the disk. FSB — Front-side bus. The FSB is the data path and physical interface between the processor and the main memory (RAM). ft — Feet. FTP — File transfer protocol. g — Gram(s). G — Gravities. Gb — Gigabit(s); 1024 megabits or 1,073,741,824 bits. GB — Gigabyte(s); 1024 megabytes or 1,073,741,824 bytes. However, when referring to harddrive capacity, the term is usually rounded to 1,000,000,000 bytes. graphics mode — A video mode that can be defined as x horizontal by y vertical pixels by z colors. group — As it relates to DMI, a group is a data structure that defines common information, or attributes, about a manageable component. guarding — A type of data redundancy in which a set of physical drives stores data and an additional drive stores parity data. See also mirroring, striping, and RAID. h — Hexadecimal. A base-16 numbering system, often used in programming to identify addresses in the system’s RAM and I/O memory addresses for devices. In text, hexadecimal numbers are often followed by h.

headless system — A system or device that functions without having a keyboard, mouse, or monitor attached. Normally, headless systems are managed over a network using an Internet browser. host adapter — A host adapter implements communication between the system’s bus and the controller for a peripheral device. (Hard-drive controller subsystems include integrated host adapter circuitry.) To add a SCSI expansion bus to your system, you must install or connect the appropriate host adapter. hot plug — Describes the feature of the system that enables you to swap a component of the system while the system is running. Hz — Hertz. I/O — Input/output. A keyboard is an input device, and a monitor is an output device. In general, I/O activity can be differentiated from computational activity. ID — Identification. IDE — Integrated drive electronics. A standard interface between the system board and storage devices. integrated mirroring — Provides simultaneous physical mirroring of two drives. Integrated mirroring functionality is provided by the system’s hardware. See also mirroring. internal processor cache — An instruction and data cache built into the processor. IP — Internet Protocol. IPX — Internet package exchange. IRQ — Interrupt request. A signal that data is about to be sent to or received by a peripheral device travels by an IRQ line to the processor. Each peripheral connection must be assigned an IRQ number. Two devices can share the same IRQ assignment, but you cannot operate both devices simultaneously. jumper — Small blocks on a circuit board with two or more pins emerging from them. Plastic plugs containing a wire fit down over the pins. The wire connects the pins and creates a circuit, providing a simple and reversible method of changing the circuitry in a board. K — Kilo-; 1000. Kb — Kilobit(s); 1024 bits.

Glossary

123

Downloaded from www.Manualslib.com manuals search engine

KB — Kilobyte(s); 1024 bytes. Kbps — Kilobit(s) per second. KBps — Kilobyte(s) per second. key combination — A command requiring you to press multiple keys at the same time (for example, ). kg — Kilogram(s); 1000 grams. kHz — Kilohertz. KMM — Keyboard/monitor/mouse. KVM — Keyboard/video/mouse. KVM refers to a switch that allows selection of the system from which the video is displayed and for which the keyboard and mouse are used. LAN — Local area network. A LAN is usually confined to the same building or a few nearby buildings, with all equipment linked by wiring dedicated specifically to the LAN. lb — Pound(s). LCD — Liquid crystal display. LED — Light-emitting diode. An electronic device that lights up when a current is passed through it. LGA — Land grid array. A type of processor socket. Unlike the PGA interface, the LGA interface has no pins on the chip; instead, the chip has pads that contact pins on the system board. Linux — A UNIX-like operating system that runs on a variety of hardware systems. Linux is open source software, which is freely available; however, the full distribution of Linux along with technical support and training are available for a fee from vendors such as Red Hat Software. local bus — On a system with local-bus expansion capability, certain peripheral devices (such as the video adapter circuitry) can be designed to run much faster than they would with a traditional expansion bus. See also bus. LVD — Low voltage differential. m — Meter(s). mA — Milliampere(s).

MAC address — Media Access Control address. Your system’s unique hardware number on a network. mAh — Milliampere-hour(s). Mb — Megabit(s); 1,048,576 bits. MB — Megabyte(s); 1,048,576 bytes. However, when referring to hard-drive capacity, the term is often rounded to mean 1,000,000 bytes. Mbps — Megabits per second. MBps — Megabytes per second. MBR — Master boot record. memory address — A specific location, usually expressed as a hexadecimal number, in the system’s RAM. memory module — A small circuit board containing DRAM chips that connects to the system board. memory — An area in your system that stores basic system data. A system can contain several different forms of memory, such as integrated memory (ROM and RAM) and add-in memory modules (DIMMs). MHz — Megahertz. mirroring — A type of data redundancy in which a set of physical drives stores data and one or more sets of additional drives stores duplicate copies of the data. Mirroring functionality is provided by software. See also guarding, integrated mirroring, striping, and RAID. mm — Millimeter(s). ms — Millisecond(s). MS-DOS® — Microsoft Disk Operating System. NAS — Network Attached Storage. NAS is one of the concepts used for implementing shared storage on a network. NAS systems have their own operating systems, integrated hardware, and software that are optimized to serve specific storage needs. NIC — Network interface controller. A device that is installed or integrated in a system to allow connection to a network. NMI — Nonmaskable interrupt. A device sends an NMI to signal the processor about hardware errors. ns — Nanosecond(s).

124

Glossary

Downloaded from www.Manualslib.com manuals search engine

NTFS — The NT File System option in the Windows 2000 operating system. NVRAM — Nonvolatile random-access memory. Memory that does not lose its contents when you turn off your system. NVRAM is used for maintaining the date, time, and system configuration information. parity — Redundant information that is associated with a block of data. partition — You can divide a hard drive into multiple physical sections called partitions with the fdisk command. Each partition can contain multiple logical drives. You must format each logical drive with the format command. PCI — Peripheral Component Interconnect. A standard for local-bus implementation. PDU — Power distribution unit. A power source with multiple power outlets that provides electrical power to servers and storage systems in a rack. peripheral — An internal or external device, such as a diskette drive or keyboard, connected to a system. PGA — Pin grid array. A type of processor socket that allows you to remove the processor chip. pixel — A single point on a video display. Pixels are arranged in rows and columns to create an image. A video resolution, such as 640 x 480, is expressed as the number of pixels across by the number of pixels up and down. POST — Power-on self-test. Before the operating system loads when you turn on your system, the POST tests various system components such as RAM and hard drives. processor — The primary computational chip inside the system that controls the interpretation and execution of arithmetic and logic functions. Software written for one processor must usually be revised to run on another processor. CPU is a synonym for processor.

protected mode — An operating mode that allows operating systems to implement: • A memory address space of 16 MB to 4 GB • Multitasking • Virtual memory, a method for increasing addressable memory by using the hard drive The Windows 2000 and UNIX 32-bit operating systems run in protected mode. MS-DOS cannot run in protected mode. PS/2 — Personal System/2. PXE — Preboot eXecution Environment. A way of booting a system via a LAN (without a hard drive or bootable diskette). RAID — Redundant array of independent disks. A method of providing data redundancy. Some common implementations of RAID include RAID 0, RAID 1, RAID 5, RAID 10, and RAID 50. See also guarding, mirroring, and striping. RAM — Random-access memory. The system’s primary temporary storage area for program instructions and data. Any information stored in RAM is lost when you turn off your system. RAS — Remote Access Service. This service allows users running the Windows operating system to remotely access a network from their system using a modem. readme file — A text file, usually shipped with software or hardware, that contains information supplementing or updating the product’s documentation. read-only file — A read-only file is one that you are prohibited from editing or deleting. ROM — Read-only memory. Your system contains some programs essential to its operation in ROM code. A ROM chip retains its contents even after you turn off your system. Examples of code in ROM include the program that initiates your system’s boot routine and the POST. ROMB — RAID on motherboard. rpm — Revolutions per minute. RTC — Real-time clock. SAS — Serial-attached SCSI.

Glossary

125

Downloaded from www.Manualslib.com manuals search engine

SATA — Serial Advanced Technology Attachment. A standard interface between the system board and storage devices. SCSI — Small computer system interface. An I/O bus interface with faster data transmission rates than standard ports. SDRAM — Synchronous dynamic random-access memory. sec — Second(s). SEL — System event log. Used in the system management software to record system events and errors. serial port — An I/O port used most often to connect a modem to your system. You can usually identify a serial port on your system by its 9-pin connector. service tag — A bar code label on the system used to identify it when you call Dell for technical support. simple disk volume — The volume of free space on a single dynamic, physical disk. SMART — Self-Monitoring Analysis and Reporting Technology. Allows hard drives to report errors and failures to the system BIOS and then display an error message on the screen. SMP — Symmetric multiprocessing. Used to describe a system that has two or more processors connected via a high-bandwidth link and managed by an operating system, where each processor has equal access to I/O devices. SNMP — Simple Network Management Protocol. A standard interface that allows a network manager to remotely monitor and manage workstations. spanning — Spanning, or concatenating, disk volumes combines unallocated space from multiple disks into one logical volume, allowing more efficient use of all the space and all drive letters on a multiple-disk system. striping — Disk striping writes data across three or more disks in an array, but only uses a portion of the space on each disk. The amount of space used by a "stripe" is the same on each disk used. A virtual disk may use several stripes on the same set of disks in an array. See also guarding, mirroring, and RAID.

SVGA — Super video graphics array. VGA and SVGA are video standards for video adapters with greater resolution and color display capabilities than previous standards. system board — As the main circuit board, the system board usually contains most of your system’s integral components, such as the processor, RAM, controllers for peripherals, and various ROM chips. system configuration information — Data stored in memory that tells a system what hardware is installed and how the system should be configured for operation. system diskette — See bootable diskette. system memory — See RAM. System Setup program — A BIOS-based program that allows you to configure your system’s hardware and customize the system’s operation by setting features such as password protection. Because the System Setup program is stored in NVRAM, any settings remain in effect until you change them again. system.ini file — A start-up file for the Windows operating system. When you start Windows, it consults the system.ini file to determine a variety of options for the Windows operating environment. Among other things, the system.ini file records which video, mouse, and keyboard drivers are installed for Windows. TCP/IP — Transmission Control Protocol/Internet Protocol. termination — Some devices (such as the last device at each end of a SCSI cable) must be terminated to prevent reflections and spurious signals in the cable. When such devices are connected in a series, you may need to enable or disable the termination on these devices by changing jumper or switch settings on the devices or by changing settings in the configuration software for the devices. UNIX — Universal Internet Exchange. UNIX, the precursor to Linux, is an operating system written in the C programming language. uplink port — A port on a network hub or switch used to connect to other hubs or switches without requiring a crossover cable.

126

Glossary

Downloaded from www.Manualslib.com manuals search engine

UPS — Uninterruptible power supply. A battery-powered unit that automatically supplies power to your system in the event of an electrical failure. USB — Universal Serial Bus. A USB connector provides a single connection point for multiple USB-compliant devices, such as mice and keyboards. USB devices can be connected and disconnected while the system is running. utility — A program used to manage system resources— memory, disk drives, or printers, for example. UTP — Unshielded twisted pair. A type of wiring used to connect systems in a business or home to a telephone line. V — Volt(s). VAC — Volt(s) alternating current. VDC — Volt(s) direct current. VGA — Video graphics array. VGA and SVGA are video standards for video adapters with greater resolution and color display capabilities than previous standards. video adapter — The logical circuitry that provides (in combination with the monitor) your system’s video capabilities. A video adapter may be integrated into the system board or may be an expansion card that plugs into an expansion slot. video driver — A program that allows graphics-mode application programs and operating systems to display at a chosen resolution with the desired number of colors. Video drivers may need to match the video adapter installed in the system. video memory — Most VGA and SVGA video adapters include memory chips in addition to your system’s RAM. The amount of video memory installed primarily influences the number of colors that a program can display (with the appropriate video drivers and monitor capabilities). video resolution — Video resolution (800 x 600, for example) is expressed as the number of pixels across by the number of pixels up and down. To display a program at a specific graphics resolution, you must install the appropriate video drivers and your monitor must support the resolution. W — Watt(s).

WH — Watt-hour(s). win.ini file — A start-up file for the Windows operating system. When you start Windows, it consults the win.ini file to determine a variety of options for the Windows operating environment. The win.ini file also usually includes sections that contain optional settings for Windows application programs that are installed on the hard drive. Windows 2000 — An integrated and complete Microsoft Windows operating system that does not require MS-DOS and that provides advanced operating system performance, improved ease of use, enhanced workgroup functionality, and simplified file management and browsing. Windows Powered — A Windows operating system designed for use on NAS systems. For NAS systems, the Windows Powered operating system is dedicated to file service for network clients. Windows Server® 2003 — A set of Microsoft software technologies that enable software integration through the use of XML Web services. XML Web services are small reusable applications written in XML that allow data to be communicated between otherwise unconnected sources. XML — Extensible Markup Language. XML is a way to create common information formats and to share both the format and the data on the World Wide Web, intranets, and elsewhere. ZIF — Zero insertion force.

Glossary

127

Downloaded from www.Manualslib.com manuals search engine

128

Glossary

Downloaded from www.Manualslib.com manuals search engine

Index
A
alert messages, 22 cooling fan modules removing, 40 replacing, 41 troubleshooting, 75 cooling shroud removing, 39 replacing, 40 cover closing, 39 opening, 38 expansion-card riser board available options, 44 connectors, 94 installing, 59 PCI buses, 94 removing, 58 external devices connecting, 13

B back-panel features, 13 baseboard management controller. See BMC. battery replacing, 59 troubleshooting, 74 bezel removing, 37 replacing, 37 BMC configuration, 33 setup module, 10 boot device configuring, 57

F fan modules, 40 front-panel features, 11

D
Dell contacting, 99-100 diagnostic messages, 22 diagnostics advanced testing options, 87 testing options, 86 when to use, 86

G guidelines for memory installation, 46

H hard drive (SAS/SATA) boot device, 57 installing, 56 troubleshooting, 78 heat sink (processor) installing, 53 removing, 50

C
CD/DVD drive See optical drive. connectors expansion-card riser board, 94 system board, 92 control panel assembly installing, 62 removing, 61

E error messages, 23 expansion cards installing, 44 removing, 45 troubleshooting, 80

Index

129

Downloaded from www.Manualslib.com manuals search engine

30

Index

I indicators back-panel, 13 front-panel, 11 NIC, 14 power, 13 installing control panel assembly, 62 expansion card, 44 expansion-card riser board, 59 memory modules, 48 optical drive, 54 processor, 50, 52 SAS/SATA hard drives, 56 system board, 64 internal hard drives, 55 IRQs avoiding conflicts, 68 line assignments, 68

M memory modules (DIMMs) configuring, 46 installing, 48 removing, 49 troubleshooting, 76 messages alert, 22 diagnostic, 22 error, 23 system, 16 warning, 22 mouse troubleshooting, 70

PCI buses riser board options, 44, 94 POST keystrokes, 10 power indicator, 13 power supply removing, 42 replacing, 43 troubleshooting, 74 PowerNow!, 28 processor installing, 52 replacing, 50 troubleshooting, 82 upgrades, 50 PXE boot entering, 10

N
NIC indicators, 14 troubleshooting, 72

R
RAID controller installing, 56 troubleshooting, 79 recommended tools, 35 removing bezel, 37 control panel assembly, 61 cooling fan module, 40 cover, 38 expansion card, 45 expansion-card riser board, 58 memory modules, 49 optical drive, 54 power supply, 42 system battery, 59 system board, 63

J jumpers, 89

O optical drive installing, 54 removing, 54 troubleshooting, 78

K keyboard troubleshooting, 70 keystrokes startup, 10 system setup program, 24

P passwords disabling, 90 setup, 30 system, 30

130

Index

Downloaded from www.Manualslib.com manuals search engine

replacing cooling fan module, 41 power supply, 43 processor, 50 system battery, 59

system diagnostics entering, 10 system messages, 16 system password, 30 assigning, 30 changing, 32 deleting, 32 enabling, 30 system security, 31 system setup program CPU Information screen, 27 entering, 10, 23 exiting, 30 Integrated Devices screen, 28 main screen, 24 Memory Information screen, 27 navigation keys, 24 options, 24 System Securtiy screen, 29 using, 24

S safety, 67 SAS configuration utility entering, 10 SAS hard drives, 55 SAS RAID controller installing, 56 troubleshooting, 79 SATA hard drives, 55 serial I/O device troubleshooting, 71 setup password, 30 assigning, 32 changing, 33 enabling, 32 startup keystrokes, 10 support contacting Dell, 99-100 system closing, 39 opening, 38 system board connectors, 92 installing, 64 jumpers, 89 removing, 63

troubleshooting (continued) mouse, 70 NIC, 72 optical drive, 78 power problems, 68 power supply, 74 processor, 82 RAID controller, 79 serial I/O device, 71 start-up routine, 67 system battery, 74 system cooling problems, 75 USB device, 71 video, 69 wet system, 72

U
USB device troubleshooting, 71

V T tools needed, 35 troubleshooting cooling fan modules, 75 damaged system, 73 equipment check, 68 expansion card, 80 external connections, 69 hard drive, 78 keyboard, 70 memory, 76 video troubleshooting, 69

W warning messages, 22

Z
ZIF socket, 50

Index

131

Downloaded from www.Manualslib.com manuals search engine

32

Index

132

Index

Downloaded from www.Manualslib.com manuals search engine

Similar Documents

Free Essay

How Companies Are Named

...w areHow companies are named? ABN AMRO- In the 1960s, the Nederlandse Handelmaatschappij (Dutch Trading Society; 1824) and the Twentsche Bank merged to form the Algemene Bank Nederland ( ABN; General Bank of the Netherlands). In 1966, the Amsterdamsche Bank and the Rotterdamsche Bank merged to form the Amro Bank. In 1991, ABNand Amro Bank merged to form ABN AMRO. Accenture- Accent on the Future. Greater-than 'accent' over the logo's t points forward towards the future. The name Accenture was proposed by a company employee in Norwayas part of a internal name finding process (BrandStorming). Prior to January 1, 2001 the company was called Andersen Consulting. Adidas- from the name of the founder Adolf (Adi) Dassler. Adobe- came from name of the river Adobe Creek that ran behind the houses of founders John Warnock and Chuck Geschke . AltaVista- Spanish for "high view". Amazon.com - Founder Jeff Bezos renamed the company to Amazon (from the earlier name of Cadabra.com) after the world's most voluminous river, the Amazon. He saw the potential for a larger volume of sales in an online bookstore as opposed to the then prevalent bookstores. (Alternative: It is said that Jeff Bezos named his book store Amazon simply to cash in on the popularity of Yahoo at the time. Yahoo listed entries alphabetically, and thus Amazon would always appear above its competitors in the relevant categories it was listed in.) AMD- Advanced Micro Devices. Apache- The name was chosen...

Words: 3479 - Pages: 14

Premium Essay

Product Development at Dell

...Product Development at DELL Since its founding in 1984, Dell corporation had enjoyed tremendous success in the desktop computer industry. Their strategy was to eliminate the middleman by directly servicing the customers through mail orders . Dell grew from obscurity to a fortune 500 company in 1992, making its founder Michael Dell one of the youngest highly successful entrepreneurs of his time. At the core of Dell’s business model was Spartanism which inspired informality in processes and low R&D costs allocation. This worked with their desktop business and their imitators such as Gateway 2000 and CompuAdd were always playing the catching-up game. However moving ahead this philosophy, their foray in to the portable computer business was not as successful. This was an industry that revolved around several technological breakthroughs and required higher workmanship & quality control to manufacture products. Here, Dell fell short of delivering quality portable computers. Their brand suffered a major setback when their first line of portables were reported to have technical problems and about 17,000 units had to be recalled just one day before the launch. Soon after, Dell’s percentage sales in portable computers went to 2% from 17%, and their stock plunged by $7 in a single day. The portable computer industry was growing fast [Exhibit 1] and was deemed to spark a new wave of consumer demand. The major problems staring Dell in face were regarding quality and management...

Words: 1668 - Pages: 7

Premium Essay

Dell Computer

...CASE:  DELL COMPUTER’S  STATE‐OF‐THE ART PRODUCTION CENTERS USING                             VENDOR MANAGED INVENTORY MODELS    Michael Dell reshaped the computer industry with build‐to‐order computers directly sold to consumers.  His business model positioned the company for emerging internet sales , with one of the highest sales  figures in the industry. But Dell has done more than streamlined the selling and distribution process, he  has also streamlined the manufacturing process as well.  Dell can deliver the latest technology exactly the way the customer wants it at blinding speed, which has  earned them the nickname of “Dellocity”.  Examples of their speed are;  they delivered eight customized  fully loaded PowerEdge Servers to NASDAQ within 36 hours of receiving the order, or when they  delivered 2,000 PCs and 4,000 servers with proprietary and multimedia software delivered and installed  at 2,000 different WALMART stores all in 6 weeks. How does Dell manage to do all this at such incredible  speeds ?? Through close customer contacts and carefully orchestrated manufacturing and distribution  system.  Dell manufactures its’ computer systems in 6 different locations‐ Texas, Tennessee, Brazil, Ireland,  Malaysia, and China.  Dell has recently added a new factory in Round Rock, Texas, called the OPTIPLEX  Plant. This factory is state‐of‐the‐art and there are only a handful of such factories in the world.  The  OPTIPLEX is a showcase of networked manufacturing.  The factory is 200...

Words: 849 - Pages: 4

Premium Essay

Business

...Dell Inc., currently a US$60 billion company, was started by Michael Dell in 1984 when he was an undergraduate student at the University of Texas, in the United States. Within two decades, Dell, with headquarters in Round Rock, Texas, grew to become one of the world’s great computer companies, with near leading shares in the personal computer (PC) and server markets. Nearly 65 per cent of its revenue originated in North and South America; 23 per cent in Europe, the Middle East and Africa; and 12 per cent in the Asia–Pacific region. In 2003, a year in which most computer makers lost money due to slumping global demand for PCs, Dell saw its annual revenues jump by US$5 billion to US$36 billion, made US$2.8 billion in operating profit, and gained 2.3 per cent in global market share. By this time Dell had gained, and held for five years, the position of market-share leader. However, during the mid to late 2000s, Dell’s position in the global PC market began to change. In 2005 it lost its market-share lead to one of its main rivals, Hewlett-Packard. By 2008–9, Dell’s second-place PC ranking came under threat from the Taiwanese computer maker Acer. In 2003, Acer had ranked seventh in PC sales around the world, but by 2008–9 Acer’s share of the global market had risen to 11.8 per cent, just behind Dell with 13.7 per cent and HP still on top with 19.6 per...

Words: 259 - Pages: 2

Premium Essay

Giving Credit Where Credit Is Duw

...Krames (2003) is very enlightening an intuitive. Michael Dell according to Krames (2003) believes in the power of the customer, be it their positive or negative feedback, but especially in what the customer wants from a product (p. 56). Michael Dell birth a business model based solely on a one-on-one relationship with customers is the foundation of his company the Dell Corporation. Andy Grove’s model mandates protection or maximization of sales opportunities so to be prepared for all possibilities of success or failure which he based on Time magazine’s 1997 person of the year Andras Grof paranoid perspective (Only the paranoid survive) (Krames 2003, pp. 66-67). Business partner Moore’s metaphorically likened their organization to that of a three legged stool, if one leg is off balance so is the entire organization (Krames 2003, pp. 137-139). Lastly, Grove named the fear of an organization being on the brink of total failure as a “strategic inflection point” (SIP) which he describes as an organizations face-to-face with massive must change events even to a point of complete organizational failure (Krames, 2003, p. 141). Resistance Comparison Michael Dell organization encountered near death when the brilliance of his technical engineering team and himself put together a massive computer (The Olympic) that customers had no real need for, which in-turn caused a huge financial loss to the Dell corporation. Michael Dell went back to basics which involved customers from the beginning...

Words: 921 - Pages: 4

Premium Essay

Busn 412

...The Acer Group is one of the world's largest PC and computer component manufacturers. Associated Acer companies include the world's third largest PC manufacturer, and Acer's mobile computers, network servers and personal computers are ranked in the world's top ten most popular brands in their respective product categories. Acer is the market leader in many countries around the world, and is ranked in more than 30 countries globally owing to the strength of its core business. On the distribution side, in 2007 it is the world's No.4 PC branded PC vendor, number one in South East Asia, Latin America and Middle East, etc... Since spinning-off its manufacturing operation, Acer has focused on globally marketing its brand-name products: mobile and desktop PCs, servers and storage, LCD monitors and high-definition TVs, and handheld/navigational devices. Acer's unique Channel Business Model is instrumental to the company's continued success. The model encourages partners and suppliers to collaborate in a winning formula of supply-chain management, allowing Acer to provide customers with fresh technologies, competitive pricing, and quality service. Established in 1976, Acer Inc. employs 5,300 people supporting dealers and distributors in more than 100 countries. Estimated revenue for 2006 is US$11.31 billion (Acer Annual Report 2005). Stan Shih, the founder and chairman of the Acer group and widely regarded as a high-tech visionary, had a long term vision to transform the Group into a...

Words: 6727 - Pages: 27

Premium Essay

Acer's Strategy

...1. Acer's strategy has been described as "divide and conquer." Compare and contrast this to Lenovo's strategy. From the very beginning Acer has been a leading marketer of notebook and desktop PCs that were relabeled electronic products marketed and sold by recognized global companies. Acer struggled growing its business in the American market. To address this issue Acer spun off its manufacturing operations to transform from a global PC manufacturer to a marketing and services powerhouse by producing products faster, cheaper and more efficiently. The most effective way for Acer to grow was to engage in expanding its operations, marketing and selling activities to another market. In this case Acer decided to take the company globally and begin building a solid market in China. It's believed that if China becomes the company's "home" market, Acer will capture critical economies of scale that will allow it to develop innovative new products that will succeed in China as well as the rest of the world. Acer's chief technology officer, believes that Acer's knowledge of China's market will help the company achieve its growth and market share objectives. Acer implemented initiatives that placed them in a better position than Lenovo. At first Acer was suffering from poor brand recognition. Consumers were concerned about the quality and the reliability of its products. One of the ways that Acer overcame this obstacle was acquiring Gateway which created a path for Lenovo to their...

Words: 1033 - Pages: 5

Premium Essay

Week Five Individual Paper

...Business Analysis Business Analysis In this paper, an overall business analysis of Apple Inc. will discuss the company’s financial statements, the company’s financial health and how it compare to other companies in the industry and globalization and how it has affected the company’s business strategies. Lastly, a benchmarking analysis will be conducted in the following comparison with other companies in the same industry. Apple Inc. has the talents of Steven Jobs along with other top idealists. Having such talent clearly gives Apple the advantage over other competitors in this industry. The collaborative efforts of the leaders give Apple Inc. a clear strategic advantage. Apple main goal is to stay on top of its competition. In order to accomplish this goal, the employees have to spend long hours determining what the consumer’s want and how to design their products based on that outcome. A good example would be the development of the iPhone. The iPhone was derived from a display of information of the iPod. This included a bigger touch screen that helped in the development of the smart phone. This vision didn’t stop there; Jobs began to think in the future toward concepts of applications for the smart phone. Once it was realized that the iPhone was a personal computer, three years later Apple Inc. introduce the iPhone and its application system. According to (Bajarin, 2011) Apple raises the bar with every new generation of the iPhone. Apple’s new version of the iPad has stood...

Words: 1687 - Pages: 7

Premium Essay

Dell Company

...Dell Company Today, I would like to talk about a famous computer company called Dell. I chose to write about Dell company because it has become one of the most successful corporation in the computer business. From the year 2000, Dell Computer has become the U.S. leader in personal computer sales and the second biggest one worldwide. Before I start on my presentation, I would like to ask a question: What has made Dell company set apart from most computer companies? My presentation will be focusing on answering this question. But, before I answer such a question, let me first give us a brief history of Dell Company. Firstly, looking at the background of Dell company. Dell Company was founded in 1984 by Michael Dell who was a college student at that time. Michael Dell started out his business by buying computer parts from the wholesale distributors, assembled them using IBM models, and sold these computers via mail at a high price. Then, Dell expanded rapidly and its growth move fast. Now, Dell employs more than 77,000 people around the world. Now, let me talk about the secret behind the great success of Dell company. Dell has followed two strategies, which no company has ever thought about. The first strategy is to sell computers directly to consumers. In this way, they eliminate the need for retailers to serve as middle-men. This process is known as a "direct business model". It has made Dell to grow...

Words: 423 - Pages: 2

Premium Essay

Dell vs. Hp

...1.Which company is competitively stronger—Dell or Hewlett-Packard? HP is still competitively stronger than Dell today in regards to overall sales. While Dell had been the industry leader in lean manufacturing approaches and cost-efficient build-to-order production methods in producing desktop PCs, it had fallen behind in producing laptop computers. The three elements in Dell’s business strategy included: entering the white-box pc segment, advertising, and continuously reducing costs. While these strategies have brought success to Dell, the Hewlett-Packard Company excelled in the printer market. Dell believed that HP was using its big margins on printer products to subsidize selling its PCs at prices comparable to Dell’s, even though Dell had costs that were about eight percent lower than HPs. Since the computer technology industry is constantly changing, the market leaders shift all the time. Currently Acer Inc. is close to taking over HP’s industry lead. 2.What actions and strategy changes would you recommend to Michael Dell to boost the company’s performance and its prospects for overtaking HP in global sales of PCs? Most of HP’s global market share in PCs and servers came from having the world’s biggest and most diverse network of distribution partners. The percentage of PCs and servers sold by its direct sales force and by its various channel partners varied by geographic region and country. The customer buying patterns and market conditions from these different...

Words: 328 - Pages: 2

Premium Essay

Dell Case Analysis

...Abstract Company Overview Michael Dell, who was a student at the University of Texas, decided to establish a computer company with a capital of only $1000. He was following the "direct model" concept where all the products were customized based on the orders and requests of the customers. It is headquartered in Round Rock, Texas but receives nearly half of its revenues from outside the United States. Dell offers produces and markets a wide range of technology products for the consumer, education, enterprise, and government sectors. In addition to a full line of desktop and notebook PCs, Dell offers network servers, data storage systems, printers, Ethernet switches, and peripherals such as displays and projectors. In addition to third-party software and many services such as asset recovery, financing, support and so on. Strategic analysis summary This case study analyzes Dell Company from a strategic perspective, which shows that Dell follows a differentiation Strategy. In the analysis of Internal and External factors; Dell has scored medium on both external and internal factors analysis with scores of (2.78) and (2.56) respectively. Showing good financial position compared to its competitors, the financial analysis revealed that the company was able to enhance and increase its market share and power after the recession especially after 2009. This study led us to recommend using the QSPM matrix. Dell has to be aware of the price war started by rivals in which...

Words: 7797 - Pages: 32

Free Essay

Integrative Thinking

...February 11, 2013 Integrative thinking (guest speaker) (an introduction) What’s going on in the world of business last week? * Blackberry 10 came out * Michael Dell said he wanted to go private * If you buy all the shares, you can make all the decisions * Corporate debt is cheaper right now in any form of financing * UK: Mark Carney fit to become the new chair for the national bank of England How do successful leaders think? * GE (Jack Walsh) * rate of return: $400 billion * first, tell your biz to be really big; second, tell your biz to be really small * too big: too many subsidiaries; can’t use money efficiently * entrepreneurs: more innovated, focus more on growths Model: idealized representation of something; exists to explain something to us * we substitute our models for the original * our models become reality * models matter so much b/c we make our decisions on them; we act overly confidently on them * investors in a stock market think their decisions based on the model * ex: there were strong belief on mortgages, but most of mortgages were toxic * “ninja mortgages”: no income, not job/assets * models actually matter more with interpersonal relations * world naturally builds opposing models * an alternative approach: seek out opposing models; use it for the better consumer goods lives and thrives on new products * P&G not doing a good job ...

Words: 535 - Pages: 3

Free Essay

Business

...The technical approach for implementing Dell Mobile Precision the five key components: (1) system functionality, (2) system architecture (3) database structure, (4) user interface and (5) products. The system at hand will be implemented by rapidly approaching clients and soliciting and developing an avenue for user feedback. This will guarantee that user issues will be taking care of, the graphical user interface is tailored to user specifications. Functions of the system: Addressing any user issues User friendly interface Each user productivity and efficiency The system initial functions were developed as a first for Dell Mobile Precision. Our development team spend much time in developing a product that tailored directly to the user and this is what the users want for a while now and we’re the first company actually take the user feedback and implement and build a system that will help minimize any user issues and the interface is very user friendly. Other functional components: - Building a road map - Synchronizing data without a delay - Stay updated - System maintenance constantly perform - Easy to use e.g. input data It is necessary for the user to stay inform of any changes and this system can help a company maximize that by using the system capability of automatically send out updates to members, but this are updates that maybe the CEO brief the mangers on. The actual update will be sent to each member of the company on the date one chooses. Staying...

Words: 1353 - Pages: 6

Premium Essay

Dell Strategy

...Dell Strategic Management Assignment/Case Study Solution Dell Strategic Management Assignment/Case Study. It reviews the organizational structure, vision, mission, SWOT, PESTEL Analysis, Strategic Group Map Competition and Product Positioning Map of Dell. This is a sample paper. If you like to order your own paper, please Click Here Introduction This report undergoes a strategic management overview of Dell, one of the leading PC vendors of the world with a unique operations model focusing on built to order and direct to consumer frameworks. The report begins with a comprehensive overview of the company’s operations, its hierarchy, location and principle of logistics. An understanding of the vision, mission and objectives allows for the strategic analysis to be put into context and perspective. Our first strategic analysis tool is the SWOT analysis followed by an internal and external factor analysis. This is accompanied by a TWOS matrix allowing the report to pin point specific strategies which may help the organization cash on its strength and opportunities to offset threats. An overview of the life cycle of the industry is followed by a PEST analysis. Understanding the political factors is critical and along with the location principles explained in the first section – allows us to pin point some strategic direction for the company. Similarly the economic, social and technological factors are discussed for the industry and the implications for Dell on a strategic level. A competitive...

Words: 4889 - Pages: 20

Premium Essay

Networking

...Laptops | ThinkPad Yoga 15.6 | KIRAbook 13 | Hard disk drive | 500 GB | 256 GB SSD | RAM | 4 GB | 8 GB | Processor | I5 2.2o GHz | I7 | Price | $949.00 Lenovo | $1599.99 Toshiba | | | | 1. Desktops | ENVY 700 | XPS 8700 | Hard disk drive | 2 TB | 1 TB | RAM | 8 GB | 12 GB | Processor | I5 3.1 GHz | I7 4.00 GHz | Price | $649.99 HP | $899.99 Dell | ThinkPad Yoga 15.6 | 15.6" 2-in-1 Business Ultrabook. (n.d.). Retrieved March 28, 2015, from http://shop.lenovo.com/us/en/laptops/thinkpad/yoga-series/yoga-15/ KIRAbook™ 13 i7S1 Touch Ultrabook™. (n.d.). Retrieved March 28, 2015, from http://www.toshiba.com/us/computers/laptops/kira/kirabook13/BOOK-13I7S1T HP ENVY 700-230 Desktop. (n.d.). Retrieved March 28, 2015, from http://store.hp.com/webapp/wcs/stores/servlet/us/en/pdp/desktops/hp-envy-700-230-desktop-pc#!&TabName=specs XPS 8700. (n.d.). Retrieved March 28, 2015, from http://www.dell.com/us/p/xps-8700/pd?oc=ddcwgp107s&model_id=xps-8700 2. Choose three different professions and describe what type of computer might be needed in that line of work. Base your judgments on hard disk capacity, RAM size, and processor speed. The three professions that I have chosen are Lawyer, Movie maker, and Scientist. The reason I have chosen them is the diversity of their needs. Not everyone needs the same thing when it comes to computers. Some need speed and processing power to run a lot of programs at once. Another may need the mobility...

Words: 553 - Pages: 3