1. WHAT IS DRUM Washing Machine?
1. Drum Washing Machine
Water consumption is reduced by using the power of the laundry falling (free-fall) created when rotating the drum. With temperature control system, this drum washing machine saves energy and improves washing performance at the same time.

2. Key Features
◆ Waist Care
Designed by the waist, and the most comfortable angle eject into the laundry is convenient and easy to manipulate.

◆ The World's First Shoes Course Enable to wash shoes. ◆ DD inverter motor
The direct-drive type of which motor is directly connected to drum without an interim chuth, significantly reduces noise and vibration.

◆ The World's First Steam White Course
The Steam White Course save more 50 percent of
Electricity, Water, Time than previous White
Course.

◆ Self-Cleaning Course of Drum.
Enable to Self-Cleaning of Drum.

◆ Star Drum
Using Star Drum is able to higher Washing
Performance and Minimal damage of laundry, water consumption.

◆ Digital Condensing Dry System.
Condensing Dry System with saveing energy.
◆ For pump drainage, the powerful pump speeds up drainage process.

◆ The biggest capacity with compact size
12 Kg Capacity enable to wash bigger laundry.

◆ AUTO DETERGENT SYSTEM
No more prepare detergent before every washing
(only liquid detergent and fabric softener)

◆ Sumultaneous supply of cold and hot water
As cold and hot water is supplied at the same time heating time and energy is saved.

◆ SMART WASH you can wash easily like stocking,lingerie use smart wash system

◆ Luxury Audio Dial
Using the advanced Audio Dial is luxury design of exterior. 1

2. Washer Specification
1. Product Specification

1 UD123X SERIES

6
4
8
NO

6

CABINET
BUTTON DIAL

630mm(W) x 792mm(D) x 991mm(H)
82 kg

WATER CONSUMPTION

WASH 91

WASHING CONSUMPTION
POWER SOURCE

/ DRY 51

31
220-240V/50Hz , 220-240V/60Hz, 100-127V/60Hz

WASHING

200W (Heating ) ~ 2000W

DRY

1200W ~ 2100W

WASHING

12 kg

SPIN

12 kg

DRY

CAPACITY

PLATE TOP

7

MACHINE WEIGHT

CONSUMPTION

CASE DETERGENT

8

POWER

PANEL F

5

DIMENSION(WxDxH)

PROTECT GLASS

4

1
2

FRAME DOOR O

3

7

CABINET F

2

3

PARTS NAME

1

5

7 kg

WASHING TYPE

DRUM TYPE

DRY TYPE
OPERATION WATER PRESSURE

Digital condensing dry system
29kPa ~ 784kPa(0.3kgf/cm2~8kgf/cm2)
4

3. Operating Mechanism Diagram

4. WATER SUPPLY PART
• Cold Water: 3 holes
Cold water, pre-washing
• Hot Water: 1 hole
• Water supply box, hose

Water
Supply

6. DRY PARTS
• HEATER DRY : OPTION
• BLOWER FAN
• FAN MOTOR : BLDC
• THERMISTOR
• THERMOSTAT
: FUSE, BI-METAL
• CONDENSING SYSTEM
• DRY FAN DRIVE
→ GENERATION OF HEATER’S
HEAT
→ TEMP. SENSOR
→ 110°C Off 100°C On : OPTION

Detergent
Container
Thermister

Door

Door
Switch

5. DOOR
• Door lock S/W
• Lock hinge
• Door AS: Glass
• Gasket

Drainage
Pump

7. DRAINAGE PART
• Drainage pump
• Valve housing
• Hose

6

Washing
Heater

1. CONTROL PART
• Main PCB
• Front PCB
• Harness
• Noise filter
• Power Cord: 15A

Electricity Input
Noise Filter

Program

2. DRIVING PART
• BLDC motor
• Drum
• Bearing
• Spider/ shaft
• Tub
• Weight balancer

BLD
C
Motor

Drum

3. HEATING PART
• Water Heater: 1000W ~ 2000W
• Washing temperature sensor
Thermister

8. SUPPORTER
• DAMPER AS : Front 2(70) / Rear 2(110N)
• Spring : 2

7

2) Dry Function Diagram

T : Thermistor
(CONTROL
HEATER’S
TEMPERATURE )

DRY DUCT

HEATER
T

FAN MOTOR
WATER SUPPLY

CONDENSING
DUCT

DRUM

DRAIN
HOUSING

While rotating DRUM, DRY HEATER applice heat to air and FAN blows it into DRUM evaporating water in the laundry.
• Evaporated water is sucked into CONDENSING DUCT, and condensed in DUCT contacting WATER SUPPLY (condensed water is extracted through DRAIN HOUSING).
• Dry function is performed by continuous repetition of evaporating and condensing circulation as above.

3) Temp- Time Graph During Dry Cycle
DRYING PROCESS
ZONE
건조진행구간
TEMP.
온도

INSIDE
DRUM
TEMPERATURE OF

내부온도

PRE
예열
HEATING

구간

TIME
시간

65

4. Parts list by ass’y
1. PANEL F AS

1 UD123X SERIES

8

No

Part Name

Part Code

Description

Qt'y

P1

BUTTON LIQUID

3616641600

ABS

1

P2

BUTTON RES

3616641700

ABS

1

P3

BUTTON SELECT DETERGENT

3616641800

ABS

1

P4

BUTTON ADD

3616641900

ABS

1

P5

BUTTON FUNCTION

3616643200

ABS

1

P6

SPRING BUTTON

3615116300

SUS, ID=9.5,d=0.5,L=15

4

P7

DECORATOR WINDOW DISPLAY

3611692700

ABS

1

P8

PANEL INNER

36142T1G00

ABS

1

P9

PANEL OUTER

36142T1F00

ABS

1

P10

BUTTON PS

3616641500

ABS

1

P11

WINDOW DISPLAY

3615508400

투명 ABS

1

P12

WINDOW COURSE

3615508500

투명 ABS

1

P13

DECORATOR FILM COURSE

P14

DECORATOR WINDOW COURSE

3611692800

ABS

1

P15

DECORATOR BUTTON DIAL

3611692900

ABS

1

P16

BUTTON DIAL OUTER

3616643700

ABS

1

P17

BUTTON DIAL INNER

3616642500

ABS

1

P18

CASE PCB F

36111T1G00

HIPS

1

P19

HOLDER LED COURSE

3613057100

HIPS

1

P20

PCB ASS'Y

1

P21

CUSTOM LED

1

P22

PROTECTOR PCB

P19

SCREW TAPPING

1

3618345400

SECC 0.6t
T2 TRS 4x14

9

1
10

Remarks

2. INLET BOX AS

B25

B26

B22
B28

B03

B23

B27

B04

B29
B21

B08
B09
B07

B10

B11
B19

B18

B17

B06

B20

B12
B01
B02

B16

B05

B13

B14

B15

B20

12

B24

No

Part Code

Part Name

Description

B01

3610528200

BOX INLET

PP

1

B02

3613274100

HOSE INLET

EPDM

1

B03

3618110600

NOZZLE TOP

PP

1

B04

3618110700

NOZZLE UNDER

PP

1

B05

36189L7000

UNIT PUMP AS

DWD-U120R 220-240V 50/60HZ

2

-

3612799200

HARNESS FEED

DRUMUP-2ND, AUTO-FEED SUB-HARNESS

1

B06

3615304800

SUPPORTER BOX

SBHG 1.2T

1

B07

3610610500

BRACKET SENSOR

ABS

4

B08

3614825900

SENSOR LIQUID A

TAB#250+PIPE(59.5)

1

B09

3614826400

SENSOR LIQUID B

TAB#250+PIPE(64.5)

1

B10

3614826500

SENSOR LIQUID C

TAB#250+PIPE(77.8)

1

B11

3614826600

SENSOR LIQUID D

TAB#250+PIPE(82.8)

1

B12

3614426000

PIPE JOINT I

PP

1

B13

3614426100

PIPE JOINT Y

PP

1

B14

3613273500

HOSE CLEANING TANK L

EPDM

1

B15

3613273700

HOSE CLEANING TANK R

EPDM

1

B16

3613273600

HOSE CLEANING TUB

EPDM

1

B17

3614010300

PACKING CLEANING

EPDM

2

B18

3611910500

FILTER

SUS. MESH 100

2

B19

3614825200

SENSOR PRESSURE

5V DRUM, DN-DD01, DL-DW01 INLET 90

1

B20

3611203200

CLAMP AS

ID=60, WIRE+GUIDE+BOLT+NUT

2

B21

3613270930

HOSE WATER SUPPLY

EPDM ID8.5 OD12.5_SHOWER

0.23

B22

3613270930

HOSE WATER SUPPLY

EPDM ID8.5 OD12.5_SHOWER

0.125

B23

3613270930

HOSE WATER SUPPLY

EPDM ID8.5 OD12.5_SHOWER

0.4

B24

3613270930

HOSE WATER SUPPLY

EPDM ID8.5 OD12.5_SHOWER

0.165

B25

3615414800

VALVE INLET

220-240V 1-WAY HOT PP-BRACKET

1

B26

3615415050

VALVE INLET

220~240V,3WAY,RINSE GUIDE유,PP/BRACKET

1

B27

3611205800

CLAMP HOSE

100H, ID=13.8 W=10.0 0.9T

12

B28

3614413300

PIPE JOINT(HOSE INLET)

PP

1

B29

3613270930

HOSE WATER SUPPLY

EPDM ID8.5 OD12.5_SHOWER

13

Qt'y

0.67

Remarks

3. CABINET F ASSY

C02

C16

C08

C09

C04
C03
C05

C06
C13
C14
C15

C12

C07

C10

C11

14

C01

No

Part Code

Part Name

Description

C01

3610813000

CABINET F

SECD 0.8T, DWD-T120R

1

C02

3614539800

PLATE HINGE SUPPORT

SPG 0.8T, DWD-T110R

1

C03

3612209800

FRAME DOOR I

PP, DWD-T110R

1

C04

3612904100

HINGE SAFETY LOCK

NYLON66

1

C05

361A113200

DOOR SAFETY LOCK

NR

1

C06

361A110600

DOOR GLASS

GLASS (DWD-100DR)

1

C07

3618304300

PROTECTOR GLASS

ABS UT0510TNP

1

C08

3612903800

HINGE DOOR

AL, DWD-T110R

1

C09

3610916500

CAP HINGE DOOR

POM

4

C10

3612211400

FRAME DOOR O

ABS

1

C11

3611692500

DECORATOR DOOR O

ABS

1

C12

3612612200

HANDLE DOOR

ABS

1

C13

3613100900

HOOK DOOR

ZNDC

1

C14

3615115400

SPRING HOOK

SUS304,

1

C15

3613101000

HOOK SHAFT

SUS, D=3.0

1

C16

3619047200

SWITCH DOOR LOCK

DL-S1.250V16A.BITRON

1

3619047210

SWITCH DOOR LOCK

DL-S1.125V 16A , BITRON

1

15

Qt'y

Remarks

4. CABINET ASSY

16

No

Part Code

Part Name

Description

D01

3618103110

NOZZLE AIR

PP, DWD-100DR

1

D02

3612209300

FRAME TOP R

DWD-T110R, GI 1.6T

1

D03

3612209400

FRAME TOP L

DWD-T110R, GI 1.6T

1

D04

3610812900

CABINET

SGCC 0.8T, DWD-T120R

1

D05

3611425540

COVER BACK AS

COVER BACK + PAD CABINET

1

D06

3612209500

FRAME UPPER

DWD-T110R, SBHG 1.2T

1

D07

3612204201

FRAME LOWER

SGCC 1.0TX634*186 DWD-110RP

1

D08

3612608100

HANDLE CABINET

PP, DWD-100DR

2

D09

3612209600

FRAME COVER

DWD-T110R, SBHG 1.6T

1

D10

3611146200

CASE PCB MAIN

HIPS, DWD-T110R

1

3610PCBC11

PCB AS

C-UD123XNHS

1

3610PCBC10

PCB AS

C-UD123XLHS

1

17

Qt'y

Remarks

5. BASE U AS

18

No

Part Name

Part Code

Description

Qt'y

Remarks

E01

BASE U

3610393200

PP, DWD-T120R

1

E02

SUPPORTER LEG

3615303600

PO+도금, 3.0T

4

E03

FIXTURE LEG

3612006400

ABS, DWD-100DR

4

E04

SPECIAL BOLT

3616029000

10 X 1.25, 51MM

4

E05

FOOT

3612100600

BUTYL, DWD-100DR

4

E06

REACTOR

52G043J002

DWD-100DR, 4A

1

E07

DAMPER FRICTION

361A700150

110N AKS ST=170-260 DL=197.5 LOW NOISE

2

다른 끝단은 TUB AS에 체결

E08

DAMPER FRICTION

361A700110

70N AKS ST=170-260 DL=197.5 LOW NOISE

2

다른 끝단은 TUB AS에 체결

E09

DAMPER PIN

361A700200

AKS D=14.5

4

E10

EMI FILTER(K19B)

3611909300

DWLF-K19(B110),X0.47U.Y1000P.VAR471K.NON FUSE

1

19

6. TUB ASSY

20

No

Part Name

Part Code

Description

Qt'y

F01
F02
F03
F04
F05
F06
F07
F08
F09
F10
F11
F12
F13
F14
F15

BALANCER WEIGHT
GASKET DRY
NOZZLE SHOWER
DAMPER PIN
DAMPER FRICTION
TUB FRONT
DRUM FRONT
LIFTER WASH
DRUM CENTER
DRUM REAR
SPIDER AS
GASKET TUB
AIR TRAP AS
SPRING SUSPENSION
UNIT BUBBLE PUMP

F16
F17
F18
F19
F20
F21

HOSE AIR
TUB REAR
BEARING HOUSING
BEARING INNER
BEARING OUTER
UNIT STATOR BLDC

F22

UNIT ROTOR BLDC

F23

HEATER WASH

3616109000
3612323900
3618104000
361A700200
361A700110
3618829800
3617003101
361A400600
3617003010
3617003210
361A300200
3612324300
3610AAR120
3615115800
36189L4150
3618L4G40
3613266300
3618829700
3616304600
3616303100
3616303200
36189L620A
36189L4800
36189L6300
36189L4900
3612802400
3612802410
3612802420
3612802430
3612802440
3612803600
3612803700
3612803800
3613266100
3612009300
36196TAJ00
361A700150
36189L5K30
36189L5J30
36189L5710

DWD-T120R
EPDM
PP, DWD-100DR
AKS D=14.5
AKS, 70N
FRPP, DWD-T120R
SUS, 0.5T
PP NANO-SILVER
SUS, 0.6T
SUS, 0.6T
SPIDER(ALDC)+SHAFT(S45C)
L=1810
DWD-T120R
DWD-T120R
220-240V
110-130V
EPDM
FRPP, DWD-T120R
ALDC
6206Z
6205Z
AL,DON1300W 30T 36POLE,NMT,PBT
36SLOT
DON1300W SR-FERRITE12,30~32T,NMT
MAGNET24
220V, 2KW
230V 2KW
240V,2KW
110V,1KW
120V,1KW
220V,2KW FUSE 2EA
230V,2KW FUSE 2EA
240V,2KW FUSE 2EA
EPDM
SUS0.7T
SV-MXT20D
AKS
220V-240V 50HZ
220L 60HZ
110-127V/60HZ

1
1
1
4
2
1
1
3
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1

F24
F25
F26
F27
F28

HOSE DRAIN I
FIXTURE HEATER
DRAIN MOTOR
DAMPER FRICTION
UNIT DRAIN PUMP AS

21

Remarks

20091211~
~20091211(changed)
20091211~
~20091211(changed)

EU
EU
EU

ONLY PUMP MODEL
ONLY PUMP MODEL
ONLY PUMP MODEL

7. DUCT B AS + DUCT PIPE AS

22

No

Part Name

Part Code

Description

Qt'y

G01

UNIT FAN MOTOR

36189L3Z20

ISM-7780 6DWWA 24V.

1

G02

COVER DUCT

3611428700

ALDC

1

G03

DUCT B UPPER

361A202100

ALCOST 0.5T

1

G04

CLAMP CORD

3611203330

DABE-2, A=9, B=5,3, L=105

3

G05

FAN AS

3611885900

DI33 FAN

1

G06

SCREW TAPPING

7122400811

T2S TRS 4x8

1

G07

SPECIAL SCREW AS

3616030100

TAPTITE P, TRS 4*16, WASHER

1

G08

FUSE TEMPERATURE

361A800120

128ûC(G4A0115C) 15A 250V

1

G09

FRAME HEATER FRANGE

3612209700

SBHG 1.2t

1

G10

DUCT B LOWER

361A202200

AL, 3t

1

G11

PACKING THERMOSTAT

3614009900

SILICON

1

G12

SWITCH THERMOSTAT

3619046500

ON 120ûC OFF 150ûC 230V

1

G13

HEATER DRY

3612800900

220V, 2100W

1

3612801400

230V 2.1KW

1

3612801600

240V 2.1KW

1

3612801300

110V 1.2KW

1

3612802100

120V 1.2KW

1

R40=26.065k∆Ω, R90=4.4278∆Ω

1

G14

THERMISTOR DRY

361AAAAC30

G15

PACKING RUBBER

3614009800

SILICON

1

G16

CUSHION DRY

3611570500

NBR, 20 x20 x 3T

2

G17

GASKET SEAL A

3612324200

EPDM FOAM, DIA=5, L=1335

1

G18

GASKET SEAL B

3612320810

EPDM FOAM, L=412, 4.9 x 4.4 x 4.8

1

G19

GASKET INLET

3612323800

EVA, 10 x 211 x 1T

1

G20

DUCT GUIDE

361A202300

AL, 3T

1

G21

DUCT AS

361A200850

T120R

1

G22

CLAMP AS(DUCT)

3611203700

DUCT

2

G23

BELLOWS DUCT

3616403000

EPDM

1

G24

H0SE WATER SUPPLY

3613270900

T120R응축수용

1

G25

CLAMP SPRING

3611203800

ID=15.5, T=0.6, B=10

2

23

Remarks

8. PLATE TOP ASSY

No

Part Code

Part Name

Description

H01

3614539910

PLATE T

DWD-U12

1

H02

3613559300

LABEL TOP UNIFICATION

DWD-T'S PLATE TOP

1

24

Qt'y

Remarks

9. Cover Plate AS

I04

I07
I06

I01
I02

I03
I05

No

Part Code

Part Name

Description

I01

3611430000

COVER LIQUID TANK

ABS

2

I02

3615304900

SUPPORTER LIQUID TANK L

ABS

1

I03

3615305000

SUPPORTER LIQUID TANK R

ABS

1

I04

3611430100

COVER DETERGENT

MBS

1

I05

3611430200

COVER PLATE

ABS

1

I06

3612511700

GUIDE DETERGENT MAIN

PP

1

I07

3612511800

GUIDE DETERGENT PRE

PP

1

25

Qt'y

Remarks

4. Test Mode
4-1 Load operation test mode
: You can easily check the operational status of each load and PCB assy.
1) How to enter
: Power S/W on -> While holding down the washing button, turn on the spin button three times -> The custom LED window displays ‘Ld’. –> Each time you press the water temperature button, the load operates as follows.
MICOM version -> L C (lock close) _> run -> b1,b2,b3,b4,b5,b6,b7 -> F (fan motor) -> H (Hot v/v) ->C (Cold v/v) ->
P (Pre-washing v/v) -> d ( dry v/v) -> bb (bubble) ->L1 (Liquid detergent auto injection device’s sync motor) -> L2
(softener auto injection device’s sync motor) ->dr (water discharge sync motor) -> L O (Lock S/W open)
**Motor error related items
1. b1: Hole sensor signal not received
2. b2: IPM FAULT (overcurrent) error
3. b3: Motor start
4. b4: Motor align error (RPM not equal to zero one minute after the motor brake starts operating.)
5. b5: The difference between the target RPM and the current RPM is greater than 120 RPM.
6. b6: Overvoltage error (detects more than 450V)
7. b7: Undervoltage error (detects more than 140V)

2) Characteristics
1. All the electrical components can operate when MICOM successfully detects the closed door (LC, Lock Close) and the custom LED’s Lock lamp is on.
It takes 0.5 to 1 seconds until the MICOM detects the closed door since it is actually closed.
2. While operating the load, it checks various sensors such as washing, drying temperature and water level. If any defect is found, an error message is displayed.
3. The main BLDC motor is not inspected. To inspect the main motor, a spin or washing cycle should be selected.
4. If the water level sensor, main motor hall IC, drying temperature sensor or washing temperature sensor malfunctions, an error message will be shown in test mode.
5. Motor operation is omitted. To check motor operation, you need to select a washing or spin cycle.

46

5. Error reporting function
5-1. IE (Input Error) - Error in water supply
1) Conditions of Occurrence
① In case the designated water level is not reached in 5 minutes during water supply or re-supply
2) All LEDs are turned off and 'IE' blinks in18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.

5-2. OE (Output Error) - Error in drainage
1) Conditions of Occurrence
① In case water level does not reach reset point in 10 minutes after drainage starts
2) All LEDs are turned off and 'OE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.

5-3. UE (Unbalance Error)
1) Conditions of Occurrence
① In case main spin-drying is not reached within 20 cycles of balance spin-drying
② In case balance spin-drying fails during interim spin-drying, UE occurs as the cycle moves to the next process. 2) All LEDs are turned off and 'UE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error mode is cleared by opening door and organizing the laundry in spin-dry chamber, closing door and pressing start/ temporary stop button. Then, spin-drying begins again.

51

5-4. LE (Lock Error) - Door opening error
1) Conditions of Occurrence
① When intending to begin cycle by pressing start/ temporary stop button while door is opened
2) All LEDs are turned off and 'LE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.

5-5. E1 - Water level detection error
1) Conditions of Occurrence
① In case water level is below reset or overflow is detected in line test mode
2) Water supply motor is kept on until water level falls below reset.
3) All LEDs are turned off and 'E1' blinks in 18:88 display.
4) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
5) Error display is cleared when turning off/ on power.

5-6. E2 - Overflow error
1) Conditions of Occurrence
① In case water level in water tank is above overflow level due to continuous operation of water supply valve 2) Water supply motor is kept on until water level falls below reset.
3) All LEDs are turned off and 'E2' blinks in 18:88 display.
4) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
5) Error display is cleared when turning off/ on power.

52

5-7. E4 - Water leakage during washing
1) Conditions of Occurrence
① In case water level falls below re-supply even after 15 times of re-supply prior to finishing of water heating 2) All LEDs are turned off and 'E4' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.

5-8. E9 - Abnormalities in water level sensor
1) Conditions of Occurrence
① In case water level frequency is of 15KHz or lower and 30KHz or higher during cycle due to abnormalities in water level sensor, etc.
2) All LEDs are turned off and 'E9' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.

53

5-9. Motor-related Error
1) E5 (DC-Link High Voltage) Error
① In case DC-link voltage to IPM increases to 450V or higher
② Motor operation is stopped and 'E5' is shown in display window.
③ Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④ Error display is cleared when turning off/ on power.
2) E6 (EMG) Error
① In case current detected with EMG port is of 20A or higher
② Motor operation is stopped and 'E6' is shown in display window.
③ Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④ Error display is cleared when turning off/ on power.
3) E7 (Direction) Error
① In case signal of Hall IC is different from the predicted signal according to direction of rotation
② Motor operation is stopped and 'E7' is shown in display window.
③ Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④ Error display is cleared when turning off/ on power.
4) E8 (Initial Operation Fail) Error
① In case input signal of Hall IC is abnormal due to problems in motor connection, etc.
② Motor operation is stopped and 'E8' is shown in display window.
③ Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④ Error display is cleared when turning off/ on power.

5-10. Error in Temperature Sensor
1) H2 Error - Washing temperature sensor open/ short
① In case washing temperature sensor is defective or not connected
② Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③ Error display is cleared when turning off/ on power.
2) H4 Error - Washing temperature sensor overheating
① In case temperature detected by washing temperature sensor is 95ûC or higher
② Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③ Error display is cleared when turning off/ on power.

54

3) H5 Error - Water temperature error in wool/ delicate course
① In case water temperature in wool/ delicate course is 45ûC or higher
② Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③ Error display is cleared when turning off/ on power.
4) H6 Error - Abnormality in washing heater
① Within 15 minutes after heater operation begins;
In case standard temperature is of 42ûC or lower: If temperature does not increase by 2ûC or more In case standard temperature is higher than 42ûC: If temperature does not increase by1ûC or more
② If temperature falls below standard temperature by 2ûC or more due to re-supply of water, etc., standard temperature is reset as the current temperature and error check time of15 minutes is reset.
③ Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④ Error display is cleared when turning off/ on power.
5) H8 Error - Washing heater overheating
① In case washing heater temperature increases by 5ûC or more within 30 seconds when there is no water in tank, etc.
② Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③ Error display is cleared when turning off/ on power.

55

Similar Documents