Free Essay

Plumbing

In:

Submitted By csopasion
Words 10574
Pages 43
Plumbing Handbook
A guide to working with
Water Corporation

As endorsed by

Introduction
This handbook has been produced by the Water Corporation to assist plumbers and builders to work with the Corporation and our regulators to deliver the best possible outcomes for our customers, by protecting public health, as well as public and privately owned assets. We recognise the need for government bodies, utilities and industry to work together to identify relevant areas of responsibility within the plumbing industry and the services delivered to the community.
In addition to their customer obligations, plumbers also have statutory obligations in protecting water and sewerage infrastructure. Laws and Regulations relevant to Water
Corporation’s operations and assets that set out these obligations are listed within this publication, to guide plumbers and builders to other documents they need to understand, when delivering plumbing services.
Information provided within this handbook was accurate at the time of print. Content updates will be made to the online version as required, available at www.watercorporation.com.au go to
Builders and Developers,Buildingand click on our Plumbing
Handbook
To be notified of updates to the handbook email building.services@watercorporation.com.au with Plumbing
Handbook Updates in the subject line.

ISBN 1 74043 565 6 January 2014

1

Plumbing Handbook

Contents
Definitions

4

Working with the Water Corporation

5

1
1.1
1.2
1.3
1.4
1.5
1.6
1.7

Connection to Water Corporation Mains
Water supply connections
Fire Services
Flow control devices
Sewer connections
Reporting of missing sewer junctions
As constructed plans
Property sewer connections to vacuum sewer systems

7
7
7
8
8
10
11
15

2
2.1
2.2
2.3

Backflow Protection
What is backflow?
Backflow flow prevention policy
Backflow prevention for new developments, redevelopments and changed water services
Backflow prevention device
Backflow regulations and standards
Ongoing device maintenance
Completing the backflow device report

17
17
17
18

2.4
2.5
2.6
2.7

19
20
21
21

3
Interpretation of Water Corporation E-Plans
3.1 Water e-plan
3.2 Sewer e-plan

22
22
23

4

Disconnection from Water Corporation
Mains – Demolitions
4.1 Water supply
4.2 Sewerage

24

5

Maintenance work

26

6

Trade Waste

28

2

Plumbing Handbook

24
25

6.1
6.2
6.3
6.4

Pre-treatment requirements
Sizing of grease arrestors – retail food industry
Non-typical grease arrestors
Discharge restrictions

28
29
31
31

7
7.1
7.2
7.3

Development Issues
Isolation of internal lines
Strata schemes
Metering

32
32
33
33

8
8.1
8.2
8.3
8.4

Buildings
Protection of services
Depth of services
Requirements on a pile diagram
Proposals to construct or alter buildings

35
35
38
39
40

9

Electrical Risks

42

10

Partnering with the Water Corporation

44

11

Legal Obligations

45

Appendix – Service and Fire Configurations

48

Contact Us

51

Revisions

52

3

Plumbing Handbook

Definitions

Licensed Plumbing Contractor
Is a person who holds a plumbing contractor’s licence under the
Plumbers Licensing and Plumbing Standards Regulations 2000.
Licensed Tradesperson
Is a person who holds a tradesperson’s licence under the Plumbers
Licensing and Plumbing Standards Regulations 2000.
Licensed Tradesperson (drainer)
Is a person who holds a tradesperson’s (drainage plumbing) licence under the Plumbers Licensing and Plumbing Standards Regulations
2000.
Flimsy
The term flimsy is used to describe the ‘as constructed’ plan of the internal plumbing constructed by a licensed plumbing contractor to connect a house to the sewer mains. Licensed plumbing contractors are legally obliged to provide the Water Corporation with the ‘as constructed’ plan or flimsy.
E-Plans
An e-plan is an extract from the Water Corporation’s mapping system which contains detailed information about water, wastewater and drainage mains. E-plans are essential for licensed plumbers when they need to locate sewer connection points.
Property Sewer
A conduit laid, wholly or partly at the expense of the property owner, entirely within the boundaries of the lot, for the carriage of sewage or wastewater to any Water Corporation sewer.
Sewers
A conduit laid for the carriage of sewage or wastewater. This term does not include a property sewer. If not specified means
Minister’s sewer

Working with the Water Corporation

Land owners proposing a building development or connecting to
Water Corporation water, sewer or drainage lines are required by law to make an application to the Corporation. Applications can be lodged online, via fax, post or at one of our offices.
BuilderNet©
BuilderNet©, our online lodgement system, is the quickest and easiest way to lodge:
 building applications (including sewer connections);
 water service application;
 sewer application; and
 requests for e-plans and flimsies.
BuilderNet© is available free of charge, with the exception of standard Water Corporation fees and charges applicable to building and service applications, and requests for E-plans and Flimsies.
Please refer to Section 1 – Connection to Water Corporation Mains
(pg 7 ), for further information about Water Corporation preconnection requirements.
Building Applications
Submit quotations and approvals for:
 minor plans for non-habitable structures (e.g. swimming pools, garages, carports and retaining walls);
 alterations or additions to existing buildings; and
 multi-residential or commercial developments (including associated water service connections and sewer junctions).
These requests are typically submitted by builders, hydraulic consultants and architects.
Water and Sewer Applications
You can also request the following:
 new water meters or services (e.g. fire services, temporary services and sub-meters);
 work on existing water meters or services (e.g. relocations, modifications, disconnections);
 new sewer junctions;

5

Plumbing Handbook



work on existing sewer services (e.g. alterations to access chambers, cutting and sealing pipes, and installing spigots); and sewer conversions, connecting properties to main sewers.

These requests are typically submitted by builders, plumbers, consulting engineers and developers.
E-Plans and Flimsies
Both types of application can be obtained via BuilderNet© for most properties, provided electronically in PDF format.
E-plans, show the location of water and sewer mains, system connections and other Water Corporation infrastructure near properties. They are particularly useful to licensed plumbers, surveyors, developers, builders, consulting engineers, hydraulic consultants, architects, local government officers and real estate agents. Flimsies feature diagrams of property sewers and show the location of internal plumbing and are particularly useful for plumbers.
How to Register
Go to www.watercorporation.com.au under Quick Links click on the link to BuilderNet©, select New Regular User and complete the form. Registration is recommended for customers that intend to use the system on a regular basis.
For further information, visit the website or contact 13 13 95

6

Plumbing Handbook

1 Connection to Water Corporation Mains

It is an offence to interfere with, alter or connect to a Water
Corporation water or sewer main without prior approval from the
Corporation.
1.1 Water Supply Connections
Connections to Water Corporation mains are provided by a meter and builders standpipe, which must be installed by the Corporation.
It is an offence to make a connection, or provide water to another property, without the approval of the Corporation. To reflect Reg
24(2)
Missing or damaged meters or damage to water services or pipe work must be reported to the Water Corporation on
13 13 75.
1.2 Fire Services
Fire services may be provided for the purpose of supplying water for fire fighting and the necessary testing of fire fighting equipment.
These services are provided by the Corporation under concessional conditions and are subject to strict conditions of use.
Unauthorised Use
Examples include washing down trucks and driveways, connecting domestic supply (including reticulation) via the fire service. If you have identified a cross connection, you must advise the customer that use of water from a fire service for purposes other than fire fighting is illegal.
Fire services are rated as a medium hazard for backflow protection
(see Section 2).

7

Plumbing Handbook

1.3 Flow Control Devices
Flow control devices (FCDs) have been installed in water services for all non-residential services since 1991.
The device limits the water supply flow rate to a flow applied for by the property owner and what has been paid for through headworks contributions. Note: FCDs control the volume of water (litres) to a property and will not reduce high water pressure, a pressure reducing valve (PRV) is required for this.
FCDs are located on the downstream face of a meter and it is the plumber’s responsibility to ensure that it remains in place when the internal pipework is fixed to the meter.
It is an offence to tamper with a meter, including the removal of the
FCD. FCDs may be the cause of a flow lower than is required by the property owner. In this case, the customer will need to apply to the Water Corporation for a larger flow and pay the appropriate headworks contributions.
FCDs can potentially cause turbulence that affects the accuracy of turbine type meters if they are placed upstream of the meter. To minimise the risk, the FCD must be placed a minimum of one metre from the meter. Prior to making an application for a water supply connection the builders/plumber must ensure there is adequate space to install the necessary pipework, between the property boundary and any buildings to accommodate the required spacing between the FCD and the meter.
1.4 Sewer Connections
Connections to Water Corporation sewer mains are provided via a connection point, which must be installed or supervised by a Water
Corporation employee. It is an offence to make a connection without the approval of the Corporation. There is a risk of asphyxiation if the correct precautions are not taken.
In addition to obtaining Water Corporation approval to connect to mains prior to undertaking any plumbing work, a licensed plumbing
8
Plumbing Handbook

contractor must submit the necessary documentation to the
Plumbers Licensing Board, including:
 notice of intention
 certificate of compliance
The Plumbers Licensing Board must also be advised once works have been completed. The licensed plumbing contractor must submit an ‘as constructed’ plan (flimsy) of plumbing work to the
Water Corporation within 60 days of completion of building work if the plumbing is part of the work. If the plumbing work is not part of the building work within 60 days of completion of the plumbing work.
It is essential that the licensed plumbing contractor/builder confirms there is adequate fall to the sewer main prior to starting building construction. The conditions a builder must comply with are included with the approval provided by the Water Corporation.
Other important requirements are:
 confirm location of the sewer connection point;
 provide for overflow relief;
 Corporation access chambers must be kept clear for ease of access;  maintain minimum cover levels on Corporation sewer mains;
 exercise caution when changing site levels;
 verify the location of existing pipe work prior to construction or connection;  obtain separate approval where industrial or commercial waste will be discharged; (see Section 6); and
 provide backflow prevention devices for specified industrial and commercial developments (see Section 2).
NEW CONNECTIONS
Construction of the main drain within a property is the responsibility of the land owner. In those situations where a new sewer connection point (sewer junction) is cut into a sewer main it must be installed or supervised by a Water Corporation employee.
It is the responsibility of the licensed plumber to;
 Make application, and make payment, to the Water Corporation for the connection
 Excavate to the sewer and make the site safe for the Water
Corporation operative to cut in the sewer connection
 Construct the property connection into the property boundary
9

Plumbing Handbook

 Provide as constructed information showing INs and UPs as well as all property sewers located within the property. (Refer to
< > for further detail)
 Show all boundary traps and other fittings
 Confirmation if the size of the property connection is greater than 100mm
Boundary/Running Traps
Boundary traps shall be installed on all property connections where the junction is located on:
 sewers that are 300mm or larger in diameter;
 IO or IS sewers where the downstream sewer is 300mm or larger in diameter; and
 Sewer regardless of diameter, that convey a pumped discharge.
As per Wastewater Manual Volume 1 Part 4, Section 10.4.3. Refer to Water Corporation drawing AA01-61-2 and in accordance with
AS/NZS 3500:2003 Part 2, Clause 4.4.
For further information about the provision of boundary traps on property connections please contact Water Corporation Building
Services on 13 13 95.
Gullies in Flood Prone Areas
All external gullies in flood prone areas, including the North West
Region (North of 26¡ South), must be fitted with “pop up” covers.
1.5 Reporting of Lost Sewer Junctions
The builder/plumber is required to confirm the location and depth of a sewer connection point prior to work commencing. The Water
Corporation provides a diagram showing the location of sewer connection points (junctions) at the time an application to connect is made. When establishing the position of the connection point you must be particularly careful where the connection is relatively long or where there are “in and up” measurements provided.
On occasions licensed plumbers experience difficulty in locating the junction (see Section 3 for information on how to interpret Water
Corporation plans). The following explains the process and any pre-requisite actions for reporting a lost sewer junction.
Prior to reporting a lost junction, you must confirm that:
1. You have valid and current approval from the Water
Corporation to connect to the sewer.
2. You have the name of the licensed plumber responsible for the site.
10

Plumbing Handbook

3. You have excavated at least 1 metre either side of the given measurement and 0.6 meters deeper than the depth shown on the e-plan. Note: report of a lost junction will only be accepted from the licensed plumber responsible for the site.
All reports shall be made by contacting the Water Corporation on
13 13 95.
You will be asked to confirm that the pre-requisite steps have been undertaken. You will be required to accept that the Corporation may seek to recover any costs should the junction be located within the correct limits. Where the excavation can be safely secured you will be required to do so pending resolution.*
Where the excavation cannot be secured you will be required to backfill. **
On receipt of a Lost Junction Report the Corporation undertakes to expedite a resolution.
You will be advised at the time of making a report of the likely resolution date.
The Water Corporation will not be able to assist if the plumber/builder has not followed this process, there is no record of a current application to connect to the sewer and a copy of the plan is not available on site.
* The licensed plumber is responsible for the safety of site excavations at all times.
**Prior to backfilling the excavation it is recommended that photographs are taken to support of your Lost Junction Report.
1.6 As Constructed Plans (Flimsies)
The provision of flimsies detailing plumbing work assists in sewer maintenance and allows the Water Corporation to manage discharge of waste into sewer mains.
Licensed plumbing contractors have a legal obligation to provide this information, and while many regulatory responsibilities have been transferred to the Plumbers Licensing Board plumbers are still required to submit sewer flimsy information to the Corporation.

11

Plumbing Handbook

The following Water Corporation Regulations requires plumbers to submit flimsy drawings of plumbing work to the Corporation within
60 days of completion of any building work that the plumbing is associated with. Regulation 53(2) Water Services Regulations 2013
(WA)( penalty $100 per flimsy)
Within the Perth metropolitan area, flimsies submitted to the
Plumbers Licensing Board will be forwarded to the Water
Corporation.
Care must be taken when preparing the flimsy plan to ensure the dimensions are accurate and legible. It is the licensed plumbing contractor’s responsibility to ensure the accuracy of the plan, and it is good practice to provide the land owner with a copy of the plan with their copy of the certificate of compliance.
Preparation and Interpretation of Property Sewer Plans
Three important components required to interpret a flimsy property sewer plan:
 Abbreviations
 Datum points and
 Inspection openings.
Abbreviations
The following abbreviations are used by the plumbing industry to indicate plumbing fixtures and other important aspects of the drainage system.
WC Water closet
Bth Bath
VP
Vent pipe
RS Rising shaft
S
Kitchen sink
Tr(L) Wash trough
ORG Overflow relief gully Ur
Urinal
B
Basin
Shr Shower
ISSOB
Inspection shaft square on back
ISRS Inspection rising shaft
Datum Points
Fixed starting points for locating an opening in a property sewer.
Although buildings may be used as datum points, it is preferred that the boundary is used and building offsets are shown together with the pipe locations.
 Datum points are indicated as 00
 There are always two datum points

12

Plumbing Handbook

Datum points must be taken from a permanent location, that is a main building or boundary fence, but the boundary is preferred.

Inspection Openings
An opening in the property sewer for maintenance purposes
 Inspection openings are indicated as IO
 Rising shafts are indicated as RS
 Inspection openings can be located by reading the appropriate two measurements from the datum points.
Note: IS RS, or ISSOB is the connection point to the Water
Corporation main sewer. The
‘cover’ indicates the depth of the property sewer at that point.

13

Plumbing Handbook

The diagram below should be read in conjunction with this instruction. 14

Plumbing Handbook

INs and UPs"
IN MEASUREMENTS
In those situations where the property sewer (property connection) has been brought into a property the as constructed sketch must include IN measurements from the centreline of the sewer main to the connection end points within the property (Refer to section
1.5)
UP MEASUREMENTS
In those situations where the property sewer has been brought into a property the as constructed sketch must include UP measurements from the invert of the sewer main to the connection end points within the property (Refer to section 1.5)
It is always assumed that the pipe is brought IN before UP unless it is otherwise stated.
1.7 Property Connections to Vacuum Wastewater Systems
Gravity sewerage systems are preferred to service properties.
However, at times a gravity flow connection from a property is not possible. In such cases, the Water Corporation may allow an alternate method to connect the property to its wastewater system, such as a vacuum wastewater system.
This type of wastewater system commences with conventional gravity house drainage, with a short length of gravity sewerage main that is connected to a collection chamber. The collection chamber has an interface valve connected to the vacuum main.
When the depth of stored wastewater reaches a certain level a pneumatic sensor is triggered, allowing the contents of the chamber to pass into the vacuum sewer.
The application process for connecting a property to a vacuum wastewater system is the same as connecting a property to a gravity sewer.
However, the Australian Standard AS/NZS 3500:2003 Part 2
Clause 3.18 specifies installation requirements. Licensed plumbers are expected to be aware of these requirements.
The diagram below illustrates a connection where the collection chamber is located outside the property boundary.
If you intend to connect anything other than a single residence, such as commercial or industrial properties, to a vacuum wastewater system you should obtain advice from the Water
Corporation on 13 13 95.
15

Plumbing Handbook

16

Plumbing Handbook

2 Backflow Protection

An ongoing threat to the quality of Water Corporation’s drinking water supply is the flow of water backwards from a customer’s property through their property’s water service connection (fire services included).
This water may be contaminated by the activities within the property, and may cause death, health problems or an inconvenience to persons ingesting or using the water.
2.1 What Is Backflow?
A reversal of the normal direction of water flow in a water supply plumbing system. It occurs when the water delivery main is at a lower pressure than the internal plumbing system (backsiphonage).
Backsiphonage can occur when there is a burst or ruptured water main, or due to excessive demand during fire fighting operations or other periods of high demand.
Backflow can also occur if a water pump (such as a bore pump) is cross connected to the internal water plumbing system, and is pumping bore water at a higher pressure than the water mains pressure (backpressure).
If a property’s drinking water supply is inadvertently interconnected with a source of pollution, either through a cross connection or simply a hose submerged in a container of liquid, then these pollutants could enter the water supply when there is an overpressure on the private property side or a sudden drop in water mains pressure.
2.2 Backflow Prevention Policy
Water Corporation’s Backflow Prevention Policy requires the installation of approved backflow prevention containment devices at the boundary of every water service connection to a property
(including fire services). Fire services that were installed prior to
May 2010, at this point in time are not required to install a boundary device unless the fire service is being altered at the property boundary. This Policy is supported by relevant legislation and plumbing standards.

17

Plumbing Handbook

2.3 Backflow Prevention for New Developments,
Redevelopments and Changed Water Services
At the time of approval of a building development application, redevelopment or changes to existing water services the builder/developer will be informed of the property’s risk rating.
Site-specific activity will determine the final level of backflow risk and for certain commercial and industrial processes may default the property risk rating to high.
The following building application types will be assessed for backflow risk:
 new developments;
 redevelopments of existing facilities;
 changes to any existing water service;
 additions/alterations (includes where no water service applications are included, applicable only if the property has existing meters);
 multiple residence and/or commercial (includes where no water service applications are included, applicable only if the property has existing meters);
 any applications that involve a fire service; and
 any applications where the minimum water service size applied for is greater than 25mm in size (except fire services, where the backflow advice applies regardless of the service size).
 Building application approvals also include a backflow approval sticker as part of the approved site plan document;
 a backflow approval sticker as part of the approved site plan document;  the applicable backflow information sheet (directed towards the applicant), based on the assessed backflow risk (high, medium or low); and
 a plumber’s information sheet (directed towards the applicant, who should then provide this to their nominated licensed plumbing contractor and/or hydraulics consultant).
If a property owner considers the risk rating assigned to their property is higher than the risk of activities being carried out, then the property owner may appeal this rating.
The property owner must consult a licensed plumbing contractor or hydraulic consultant first and submit an appeal form to the Water
Corporation within 28 days of being advised of the risk rating. The
Corporation will advise the property owner of the outcome of the review. 18

Plumbing Handbook








The risk rating of a property determines the minimum requirement for the type of backflow prevention device(s).
Irrespective of the risk rating of a property all fire services are rated medium risk and require (as a minimum) a medium rated device to be installed.
If the future land use is unknown the risk rating will default to high. Where there is mixed use on a property the risk rating will default to high.
Changes in the activities within a property can result in a change of the backflow risk rating and the backflow device(s) required.

2.4 Backflow Prevention Device
The backflow prevention device must be installed on the customer’s side of the drinking water connection at the property boundary and belongs to the owner of the property.
This is in addition to any zone or individual backflow prevention devices installed within the property.
The Water Corporation registers all testable backflow prevention devices installed at the boundary of the customer’s property. The licensed plumbing contractor installing the device must inform the
Water Corporation of the installation within 5 working days by submitting the backflow device test report.
The following conditions should be noted:
 Boundary containment backflow prevention devices are required to be installed as part of the plumbing system downstream and as close as practicable to the property’s water meter (or property boundary if no water meter is available). Refer to the
Appendix on page 50.
 Devices are to be adequately supported and no part of any fitting or containment device is to be installed closer than the greater measurement of 5 pipe diameters or 300 mm from the meter outlet, whichever is greater.
 No connections are permitted between the meter outlet and the containment device.
 If continuity of supply is critical to your client, consideration should be given to connecting duplicate devices in parallel.
 If the property has more than one new water service you will need to install a device/s at the connection point for each of those services.
 All fire services are rated as medium risk and the installation of a medium risk rated device is required, as a minimum.
19

Plumbing Handbook

The installation of some forms of backflow prevention devices will reduce water pressure/ flow rate downstream of the device.
If the water pressure and/or flow rate is critical to your client, then this should be discussed with your client prior to choosing and installing the final backflow prevention device.
 Work related to the installation of backflow devices is identified as plumbing work and is therefore covered by plumbing regulations. Compliance with the plumbing standards will therefore be monitored by the Plumbers Licensing Board and you are required to notify the Board of your intention to carry out the work.


Only licensed plumbers who are qualified to install, test and certify backflow prevention devices are permitted to carry out such works.
The Water Corporation will inspect properties to ensure ongoing compliance with its Backflow Prevention Policy.
2.5 Backflow Regulations and Standards
Water Corporation requirements relating to the installation, maintenance, and testing of a backflow prevention device are supported by legislation and plumbing standards.
Regulations for Backflow Prevention
The requirement to have and maintain backflow prevention devices at the boundary of a property is supported by legislation, including the following regulations:
Regulations 42 and 43 Water Services Regulations
Due to the potentially serious nature of a backflow incident, the
Water Corporation can in accordance with these regulations serve an order on a property owner or occupier to install backflow devices. The regulations also provide for penalties for non-compliance or under the Water Services Act 2012 (WA) the Water Corporation has the power to restrict or disconnect water services, to protect the drinking water supply from potential contamination caused by a backflow event from a property.
Standards for Backflow Prevention
In addition to all plumbing regulations, licensed plumbing contractors must also apply the following standards for backflow prevention: 20

Plumbing Handbook

AS/NZS 3500:2003 Plumbing and Drainage Part 1: Water
Services.
 AS/NZS 2845:1998 Water Supply-Backflow Prevention Devices
Part 1: Materials, design and performance requirements.
 AS 2845:1996 Water Supply-Backflow Prevention Devices Part
2: Air gaps and break tanks.
 AS 2845:2010 Water Supply-Backflow Prevention Devices Part
3: Field testing and maintenance.
2.6 Ongoing Backflow Device Maintenance
Testable backflow prevention devices at the property boundary must be installed on high or medium risk properties. These require testing at commissioning, after any maintenance and every 12 months by a licensed plumbing contractor, permitted to test the devices. The Water Corporation will send an annual reminder letter to the property owner for these boundary devices. Failure to maintain a backflow device will result in the serving of a non compliance notice to the property owner or occupier
Backflow test reports must be submitted to the Water Corporation no later than 5 working days after the test is carried out.
The level of detail of these test reports is critical to ensure the ongoing efficient and effective management of property boundary testable backflow prevention devices.


2.7 Completing the Backflow Device Report
1. Single use test forms can be printed from www.watercorporation.com.au select Builders and developers, click on Building, click on Backflow prevention then, at the right hand side of the page under Documents and downloads, click on Backflow device inspection and maintenance report template.
2. Complete all required fields, these are critical to allow compliance monitoring of all testable devices.
3. If a backflow device fails a test and is replaced by a different device then the complete device details of the old device and the replacement device must be provided on the test report form. 4. Lodge the correctly completed form either by fax, email or post to the contact details provided.

21

Plumbing Handbook

3 Interpretation of Water Corporation E-Plans

E-plans are extracts from the Water Corporation’s mapping system that, among other things, show the location of sewer connection points. It is essential for all plumbers to be able to interpret e-plans.
When using e-plans there are limitations in how the information may be used. Users must not rely soley on the plan. When the information is critical, the pipe position must be physically confirmed prior to any mechanical excavation or boring.
3.1 Water E-Plan
The following water e-plan is intended as a guide.

22

Plumbing Handbook

3.2 Sewer E-Plan
Some junctions in older areas (typically those prior to 1986) have not been brought into properties or up to one metre below ground level. Licensed plumbers must not rely on previous experience or the graphical representation of e-plans when locating sewer connection points.
The example below illustrates why it is necessary to accurately interpret e-plans. While the connection for Lot 517 is shown outside the property line, the dimensions show the connection point has been brought in 2.7 metres and up 1.9 metres from the sewer line.
The graphic for Lot 111 reflects the measurement which indicates it has been brought in 1.3 metres and up 1.9 metres from the sewer line. Common in older suburbs, the sewer connection point may not be brought into the property, and it is the licensed plumber’s responsibility to correctly interpret the e-plan. Refer to Section 8 –
Buildings, for direction on how to estimate depths to Water
Corporation sewer pipes.
The following sewer e-plan is intended as a guide.

23

Plumbing Handbook

4 Disconnection from Water Corporation
Mains - Demolitions

4.1 Water Supply
Prior to the demolition of any building the landowner is required to apply to the Corporation for the water service to be disconnected.
Water Service Act 2012 Section 95
In cases where redevelopment is pending the water meter may be left, subject to the installation of a standpipe by a licensed plumber, compliant with AS/NZS 3500:2003 Part 1
Where a landowner, builder or licensed plumber chooses to leave the water meter on site they will be responsible for any damage to the water service or water theft.
The diagram below illustrates how the connection for a temporary standpipe may be made

24

Plumbing Handbook

4.2 Sewerage
Prior to the demolition of any building the landowner is required to engage a licensed plumber to disconnect the building from the sewer main and ensure the sewer connection point is left sealed, compliant with Plumbers Licensing and Plumbing Standards
Regulations 2000 (WA) and AS/NZS 3500:2003 (Part 2 Clause
4.11). The diagrams below illustrate correct sewer disconnections.

Note: For PVC pipes the seal must comprise an approved cap glued to the pipe.
For earthenware pipes the approved cap must be cemented to the pipe. 25

Plumbing Handbook

5 Maintenance Work
This section provides guidelines for customers and licensed plumbers relating to maintenance responsibility for blockages in sewer property connections. The sewer property connection is the pipe between the inspection shaft and the junction on the
Corporation’s sewer main, shown as A and B on the diagram below. The guidelines ensure that property owners will not be responsible for excavation to excessively deep sewers or for excavation in another property. They apply to the inspection shaft (IS sewers), long sewerage connections and jointly used property sewers (other than in strata schemes).
1. Property owners are responsible for the cost of clearing any blockage in their sewer property connection, where the blockage can be cleared from the inspection shaft.
The Corporation will not reimburse licensed plumbers for reporting any blockage where it is found to be in the property connection and the Corporation subsequently clears from the inspection shaft.
2. If the Water Corporation determines that an excavation is required to repair the sewer property connection, the Corporation will assume responsibility for the repair if:
 the depth of the required excavation is 2.5 metres or more; and/or  excavation is required outside the property.
The diagram below illustrates the intent and interpretation of this application. 26

Plumbing Handbook

Detailed below is the process to be followed when plumbers become aware of a blockage in a sewer connection, where it fits the circumstances outlined on page 23:
1. Contact Water Corporation’s Service Faults and Emergency number on 13 13 75.
2. Advise the Customer Service Representative of the situation.
3. Obtain a work order number from the Customer Service
Representative. Keep a record of the number.
4. Invoice the Water Corporation referencing the work order number. The Water Corporation will pay the licensed plumber a standard fee, as agreed with the plumbing industry. The fee is intended to cover travel costs and the onsite assessment. The Corporation expects that no costs will be borne by the property owner.

27

Plumbing Handbook

6 Trade Waste

Trade waste is wastewater other than wastewater of a kind and volume ordinarily discharged from an ordinary dwelling used solely or primarily as the dwelling of the occupants.
Generally, any wastewater discharge from business or industrial premises, other than discharge which comes from staff amenities or office facilities, is classified as trade waste.
Not all trade waste is compatible with our wastewater system.
Does your existing or proposed business need a grease arrestor?

If you are, or will be cooking food and washing pots, pans, plates, utensils, etc, then most likely yes, your business does or will, need a grease arrestor. Fats, oils, grease and solids, can also find their way into the sewer system via floor drains.
Additionally some premises that do not specifically cook foods but undertake food preparation, or washing activities that generate quantities of suspended or gross solids, will also require a grease arrestor, i.e. butchers, meat processors, catering businesses.
Whether you are going to be a first time business owner or have been in business for many years, please enquire to see what the current Water Corporation standards, require you to have in place.
See watercorporation.com.au for approved pre-treatment products Any Industry or business in Western Australia that wishes to discharge trade waste to Water Corporation’s sewer is required by law to obtain from the Water Corporation a Trade Waste Permit.
Obtaining a an Trade Waste Permit

Complete a Trade Waste Application form, along with any relevant supplement forms and submit to the Water Corporation with a site hydraulic drawings (plumbing design drawings) for assessment prior to commencing any discharge of trade waste
6.1 Pre-Treatment Requirements
Most trade waste discharges to sewer will require some form of pre-treatment. The most common pre-treatment device is a grease arrestor, which is required for wastewater generated from greasy waste producers such as restaurants, cafés or fast food businesses. See pages 30-31 for guidance on sizing of grease arrestors. 28

Plumbing Handbook

Another common form of pre-treatment is the Coalescing Plate
Separator (CPS) or Vertical Gravity Separator (VGS), used for wastewater that contains oily water generated from businesses like mechanical servicing and vehicle wash bays. Typical drawings of pre treatment apparatus are available on the Water Corporation website. More complex wastewater may require the producer of the waste to engage a wastewater treatment or plumbing consultant to design a suitable treatment system to meet Water Corporation acceptance criteria. Does your existing or proposed business need a grease arrestor?

If you are, or will be cooking food and washing pots, pans, plates, utensils, etc, then most likely yes, your business does or will, need a grease arrestor. Fats, oils, grease and solids, can also find their way into the sewer system via floor drains.
Additionally some premises that do not specifically cook foods but undertake food preparation, or washing activities that generate quantities of suspended or gross solids, will also require a grease arrestor, i.e. butchers, meat processors, catering businesses.
Whether you are going to be a first time business owner or have been in business for many years, please enquire to see what the current Water Corporation standards, require you to have in place.
See watercorporation.com.au for approved pre-treatment products Only pre-treatment devices, which are accepted for use by the
Water Corporation should be installed and connected to the sewer.
Always check with your supplier prior to purchasing any pretreatment product.
6.2 Sizing of Grease Arrestors – Retail Food Industry
The correct sizing of a grease arrestor is critical in ensuring the efficient removal of oil, grease and solids from the wastewater discharged from a greasy waste producer.
There are two methods, Fixture Unit Rating and Peak Flow Rate that can be used to determine the correct size of a grease arrestor.
The Water Corporation has a minimum grease arrestor size of 540 litres and a maximum size of 2000 litres in effective capacity for any individual grease arrestor. Customers requiring larger grease arrestors need to obtain Water Corporation approval before installation. 29

Plumbing Handbook

Note that a grease arrestor approved previously that no longer complies with the current sizing requirements will need to be upgraded.
Peak Flow Rates Method
Where the hourly peak wastewater flow rate is known, this can be used as the ‘Calculated Grease Arrestor Size’ (see Recommended
Grease Arrestor Size table) to determine the recommended size.
Fixture Unit Rating Method
The grease arrestor size, in litres, is the sum of the fixture unit ratings of all fixtures that feed into the grease arrestor multiplied by
100 (see Fixture Rating table). Using the Peak Flow Rates Method determine the recommended grease arrestor.
Fixture Unit Ratings
Fixture
Steamer
Wok
(per burner)
Hand Basin
Rinse sink
Combi Oven

Fixture Unit
Rating
1
1

Fixture
Kitchen sink
Double kitchen sink

Fixture Unit
Rating
3
3

1
3
5

Pot sink
Double pot sink

5
5

Recommended Grease Arrestor Size
Maximum
Number of
Fixture Units
7
13

Calculated Grease
Arrestor Size Range
(litres)
100 - 700
701 - 1300

Recommended Grease
Arrestor Size (litres)

17
26
40

1301 - 1700
1701 - 2600
2601 - 4000

1500
2000
2 x 2000 in series

540
1000

Shared Grease Arrestors
The Water Corporation will only approve shared tenancy grease arrestors when the property owner, or the owner’s designated agent (such as a shopping centre manager), agrees to takes responsibility and applies for a trade waste permit. In circumstances where the Water Corporation approves businesses to share a grease arrestor the minimum size can be calculated using either method. If using method 1 the combined
30 Plumbing Handbook

fixture unit rating of all businesses sharing the grease arrestor must be used. The minimum size for a shared arrestor is 1000 litres.
Where the fixture unit loading is too high for a single grease arrestor and it is not practical to connect grease arrestors in series, the waste streams are to be split and diverted to individual grease arrestors to accommodate the fixture loadings.
6.3 Non-Typical Grease Arrestors
The Water Corporation may accept the use of other types of grease arrestors, such as those that may include the use of filters. These types of grease arrestors may be subject to specific conditions or use restrictions. It is recommended that prior to the installation of such arrestors customers seek advice from the Water Corporation.
6.4 Discharge Restrictions
Dishwashers and Glasswashers
Dishwashers and glasswashers are not to discharge into grease arrestors due to their use of detergents, high water temperatures and surge loads. This can overload the arrestor or can liquefy or emulsify oil and grease, allowing it to be discharged to sewer.
Swimming Pools
The backwash and drainage from domestic swimming pools or spas must not be connected or discharged to the sewer. Water
Services Act 2012 Section 88(1)(g)
Storm Water
Storm water from domestic or commercial premises must not be connected or discharged to the sewer as it is considered a prohibited discharge.
Food Waste Disposal Units (Garbage Grinders)
The installation of garbage grinders on any service connected to the sewer is prohibited.
.

31

Plumbing Handbook

7 Development Issues

Licensed plumbers need to be aware that issues affecting plumbing work may arise during the development of land. A development includes:  amalgamation by subdivision of two or more lots;
 any green title or strata subdivision; and
 any building on a land parcel.
 The main areas that plumbers should be aware of are:
 internal sewer or water lines that extend into another lot when a lot is subdivided;
 water meters located in a new lot that is separated from an existing house;
 sub meters that may be required on a multi-residential development or strata scheme;
It is advisable to rationalise the plumbing for any development, to minimise the number of meters and sewer connection points. This makes the property easier to manage and may reduce the annual service charges for the land.
7.1 Isolation of Internal Lines
At the time of subdivision internal water or sewer lines may be isolated from the building they are servicing. The problem is more severe if the sewer connection point or the water meter is isolated, as illustrated in the Isolation of Internal Lines diagram on page 34
In the example on the nexte page, where a single lot was subdivided into two, existing internal water and sewer lines extend into the new Lot 2. Prior to the subdivision being finalised it will be necessary to provide a new sewer connection point at B and realign the sewer line going to A so it is entirely within the new Lot
1 to a new connection point at B.
The water connection point at X would need to be relocated to Y and an additional meter provided for in the subdivision process.

32

Plumbing Handbook

7.2 Strata schemes
Through the Strata subdivision process the Corporation will ensure that access to our services is available at the boundary of the
Strata Scheme in accordance with our Operating Licence requirements and servicing Standards. The developer is responsible for ensuring that all lots proposed under the Strata
Scheme have adequate access to these services and that any existing plumbing is adequately protected.
In order to do this the developer may choose to install dormant plumbing (water and sewer) and/or relocate any existing internal plumbing. Dormant sewer or water lines are a section of internal plumbing laid in the ground for future connection of a building to the sewer or water mains. Dormant lines may be laid during the development of the strata to avoid the need for strata neighbours to intrude upon each other to install the lines after the scheme is established.
7.3 Metering
Access
The Water Corporation is the owner of the meters and associated fittings. It is illegal to tamper with any part of the meter and customers have an obligation to maintain 24/7 clear access for the meter to be read and replaced.
Multi unit developments
There are two metering options available to all residential properties and non-residential strata properties that require metering at an individual unit level.
33

Plumbing Handbook

When requested by an eligible strata company or single owner the
Water Corporation will provide multiple unit developments with metering facilities under one of the options below.
Option 1
The Corporation fits individual meters at an agreed road frontage adjacent to a water main for individually subdivided or strata titled lots. Option 2
Fit a master meter at an agreed road frontage adjacent to a water main to serve the whole property with the developer installing acceptable sub-meters to each unit at the developer’s cost. This option applies to a minimum of 3 units and is not available to nonresidential developments unless they are strata titled. Nonresidential properties that are not strata titled cannot be sub metered. Where necessary, the Water Corporation will provide advice and assist developers with establishing an automated meter reading
(AMR) servicing arrangement for high-rise, multi-level residential developments or expansive developments, where normal metering arrangements are not practicable. Costs associated with use of sub-meters are available on request.
For all sub-meter installations the work must comply with the standards and instructions issued by the Water Corporation at the time of the work being carried out, and is subject to the terms of an agreement with the strata owners detailing the selected option.

34

Plumbing Handbook

8 Buildings

8.1 Protection of Services
If you are working near the Water Corporation's pipelines you need to know how to work around them without causing damage or interference. In processing building and construction plans the Corporation ensures that adequate protection and access to services is maintained. It is important to comply with the legislation and to be sensitive to the impact on affected landowners and developers. Protection of services action is taken where required and only within the prescribed proximity to Corporation services to assess the impact on Water Corporation assets the following is required:
 a floor plan and site plan is required;
 measurements from a lot boundary are essential; and
 measurements from an existing shed, house, pool or clothesline will not be accepted.
The Zone of Influence
Is the restricted area around Water
Corporations services.
Note: the further the structure is from the Corporation service, the depth of the pile is reduced. The graph on page 35 is an example from the
Corporation’s Protection of Services
Manual, available on our website.
The manual provides guidelines for the structural protection of
Water Corporation’s water, sewer and drainage services, and requirements for access to those services, where building or construction activities are carried out in their proximity.
The Protection of Services Manual contains a variety of graphs, dependant on the type of material the pipe is made from and its size. The graphs are indicative only, if you require assistance contact us on 13 13 95.
In cases where a structure has been erected and encroaches on the area that cannot be built on, the builder is required by law to underpin the structure. In extreme circumstances the Corporation
35

Plumbing Handbook

may order the removal of the structure.

36

Plumbing Handbook

Example only must use appropriate graph

37

Plumbing Handbook

It is essential that any protection of services issues are addressed prior to construction commencement.
If the structure falls outside the ‘no restriction’ area building conditions are applicable
For further details refer to the Survey Requirements for Building
Developments information sheet, available on our website. It shows when additional survey information is required prior to boundary approval. 8.2 Depth of Services
The diagram on the following page explains how to calculate the depth of Water Corporation sewers and drains.
Guidance Notes
 Depth of sewer = 2.06m, go to the Graph (page 38) that is relevant for 150 P un-encased main.
 At 2.06m deep, slide across Graph to where there are no building requirements.
 This is at 1.5m from the centre of the sewer line.
 Is the sewer inside the property or outside the property? For this example the main is inside the property, so:
1.5m from centre of sewer to boundary
+ 0.9m from fence line to sewer
= 2.4m from lot boundary to be clear of any requirements.
If the building encroaches into the zone of influence, but not into the red zone, piling is required.

38

Plumbing Handbook

8.3 Requirements on a Pile Diagram
Where piling is required, the following detail must be provided with building plans (as detailed in the diagram on the opposite page):
 depth and width of pile indicated;
 date and signature of the structural engineer must be visible; and  a site plan showing the position and spacing of the piles.
In all instances the builder must provide the Corporation with advance notice of when the piles will be installed. Further detail of this requirement is provided with the building plan approval provided by the Water Corporation.

39

Plumbing Handbook

8.4 Proposals to Construct or Alter Buildings Acts and By-Laws
Any person proposing to build any structure in an area served by a
Water Corporation water or sewer main must obtain approval from the Corporation and pay the prescribed application fees prior to commencing construction.
The following legislation supports this requirement:
Water Services Act section 82(1)
Approval is required to protect the public assets, the Water
Corporation is responsible for managing the assets at all times, including when buildings are not under construction. This has become more important due to the increased tendency for buildings to be built close to property boundaries and hence closer to the pipes. The Corporation’s assessment ensures:
 the pipes are clear of building developments to protect access for maintenance or replacement and ensure the building load does not damage the pipes;
 any industrial discharge does not damage or contaminate the water and sewer mains;
 the building has a fit for purpose water and/or wastewater service; and
 fees required under the above legislation are paid.
Builders and licensed plumbers should also consider the following points when planning their building development:
1. The Corporation’s water and wastewater services are adequate for the proposed building or development. In some circumstances it will be necessary to extend or enlarge the existing network and connections to the property.
2. Wherever possible all survey levels provided should be in
Australian Height Datum (AHD) as it assists in ensuring the building can be adequately served by the sewer, and makes the design of piling easier. This is particularly important where the ground level has been altered.
3. Builders are responsible for establishing the location of sewer connection points prior to starting any works. In the event that the connection point cannot serve the proposed building or it is not located in the correct position the builder will be responsible for any additional works necessary. This is particularly important in the redevelopment of lots in older suburbs
40

Plumbing Handbook

4. In some circumstances the builder may need to have the location of the Corporation’s pipe work confirmed by survey. If any proposed building is within 3 metres of a pipe it is recommended that you seek advice from the Corporation or a surveyor prior to any detailed design.
5. Licensed plumbers are required by law to apply to the Water
Corporation prior to connecting a property to the sewer mains.
On some occasions this application is made by the builder, however if in doubt licensed plumbers are advised to contact the
Corporation on
13 13 95.
6. Plumbers are required to submit ‘as constructed’ plans of any work they do. Refer to Section 1.7 for further detail.

41

Plumbing Handbook

9 Electrical Risks

In August 2009 Western Power issued a bulletin as an update of an
Operational Standard, due to a serious electrical safety hazard caused by underground directional drilling activities, resulting in electrical cables being cross bored into private, local government or
Water Corporation sewers and drains.
Licensed plumbers must exercise caution when clearing blockages in or near sewer lines particularly in the front verge. The safety of plumbers is at risk if cutting tools of any type are used to clear the blockage that is potentially caused by live electrical cables.
Western Power, Horizon Power and their electrical contractors are required to take all prescribed precautions to prevent the cross boring of electrical cables into sewers, drains and other pipes and conduits, however Western
Power advises that live cables can often penetrate drainage pipes, storm water pipes, sewer mains and sewer connections to properties. This occurs due to high boring activity levels. In some instances this may be undetected until the property owner or tenant reports and seeks to clear a sewer or drain blockage.
Warning – Licensed plumbers:
 Mechanical devices and high pressure cutters can cut into a cable, presenting a serious electric shock or electrocution (I e death)  Never attempt to clear a blockage unless you are absolutely certain that a power cable is not the cause.
 Do not make assumptions about the installation or location of
 underground power cables.
Before commencing work determine if property in the vicinity of a blockage is connected to underground power. If you are unsure, the following may indicate that an underground power cable may have caused the blockage.
42

Plumbing Handbook

What to look for at the property
 Is there a green dome on the property boundary?
 Is there an underground pit within the property or on the verge?  Are there any signs of recent excavations?  Does the property have overhead or underground power from the street to the building?
What to look for in the street
 Is the area serviced by underground power to either multiple or single properties?
 Are there poles with cables attached that run from the top of the pole to the ground?
 Is there a green cabinet displaying a danger warning sign?  Are there any signs of recent excavations? Tools and Equipment
Consider the use of alternative blockage cleaning tools, such as lower pressure jet-washers. CCTV technology can also be used to positively identify the cause of blockages.
Assistance with locating underground power
Western Power on 13 13 51
Horizon Power on 13 23 51

43

Plumbing Handbook

10 Partnering with the Water Corporation

SewerSmart© Plumbers
Partnering with metropolitan plumbing companies, the
SewerSmart© program works under a Memorandum of
Understanding in accrediting SewerSmart© Plumbers, who are available 24 hours a day, 7 days a week, 365 days a year to answer and attend customer calls in relation to blocked drains. As
90% of calls coming into the Water Corporation for blocked drains are found to be the customer’s responsibility, the process aids customer satisfaction.
SewerSmart© Plumbers undertake an accreditation course in understanding and reading sewer plans, have access to Water
Corporation’s mapping system, providing quicker and easier access to internal sewer connections, and are given a fast-tracked reimbursement in relation to SewerSmart© call outs. To obtain
SewerSmart© Plumber details contact 13 13 75.
Waterwise Plumbers
The Water Corporation has had a rewarding association with the plumbing industry through the Waterwise Plumbers program, developed in 2003. The Water Corporation offers a training course, hosted by the Master Plumber and Gasfitters Association, for plumbers who wish to join the program. The training covers all activities related to water efficiency and plumbing.
Training includes:
 domestic water auditing;
 installing and plumbing of domestic rainwater tanks;
 installing grey water systems;
 installing hot water circulation pumps and systems; and
 installing flow regulators and all other water efficient plumbing products. The Corporation encourages customers to utilise the services offered by endorsed Waterwise Plumbers, with their contact details listed on our website.The Waterwise Plumbers program has become an integral component of the Enviro West plumber training and endorsement program facilitated by the Master Plumber &
Gasfitters Association.
44

Plumbing Handbook

11 Legal Obligations

The Legal References table describes some of the responsibilities plumbers have under the following water legislation:
 Water Services Act 2012
 Water Services Regulations 2013
These requirements recognise the licensed plumber’s role in protecting water and sewerage infrastructure and ensure that the interests of all customers are protected.
The list is an indication of the processes to be followed in connecting or disconnecting services and plumbers’ obligations, including providing information to the Water Corporation.
The legislation references and the information contained in this handbook should be used in conjunction with the appropriate
Australian Standards. While this handbook references Australian
Standards and West Australian legislation, it is not intended to replace them. Please refer to the following for the full text.
Legal References
Requirements/Activity

Licensed plumbing contractor to submit as constructed drawings of plumbing work to the Corporation within 60 days of completion of the work
It is an offence to place anything over a pipe which affects the Corporation’s ability to inspect or maintain it
Licensed plumbing contractor must report damage done by themselves to pipes and take steps to make repairs
Licensed plumbing contractor to report certain matters
Responsibility of landowners to keep private plumbing in good order and conduct repairs or rectifications when required by the Corporation

45

Plumbing Handbook

Water
Services Act
2012

Water
Services
Regulations
2013

53

90

51(2)
51(1)

92

No fittings to be installed within one metre of the meter
Not more than one house can be served by a single meter unless authorised by the Corporation
Items prohibited to be discharged to sewer Requirement to lodge a building application When a sewer is completed and ready to use
Circumstances where costs incurred by the Water Corporation may be recovered Authority to enter property
Misuse of water
Pipe not greater than 20mm
If an applicant requires the Corporation to reconnect a disconnected service the
Corporation has the right to recover the current cost of the disconnected service
Fire hydrants are for fire fighting only
Fire hydrants to be sealed
Additional services
The Corporation may provide and install on a building or construction site a temporary building stand-pipe together with hose-tap and pipe connection on payment by the builder of the
Builder responsible for the security of the meter
An existing water service is not to be used for a building construction until the proposed building has been approved by the Corporation
Supply may be disconnected if used in connection with any work in addition to that shown on the submitted plans on which the building fee was assessed
Meter may be fitted at the Water
Corporation’s discretion (circumstances

46

Plumbing Handbook

24(2)

125(2)
88(1)(g)
82(1)
98

25(2)
140(1)
89
21(1)

95
97
97
83&94

78
25

82(1)

89
25(1)

& size)
Meters in multi residential
Meters may be required to be installed in a pit or cubicle
Owner responsible for any damage to the meter and as such take care to protect and secure the meter
Access to meters - Meters must have a clear space around them. Where an owner changes the ground levels or causes other changes to the land the owner will need to meet the cost of any relocation to ensure the meter has adequate clearance and protection.
Damage to meters must be reported
Swimming pools not to be connected to sewer without approval
Trade Waste Requirements

23(2)
22

25(2)

24(1)
25
88(1)(g)
102,103,104
,105,106

55

Backflow prevention: owner or occupier required to install backflow prevention device when required to by the
Corporation
Backflow prevention: Reporting, testing and maintenance

Requirements/Activity
Owner must connect to sewer if sewer is completed and ready for use.
Owner or occupier required to repair and cleanse property sewers.

47

Plumbing Handbook

42
43

Water Services
Act 2012
98
92

Appendix - Service and Fire Configurations
Explanation of notes to backflow boundary protection diagrams
Note 1
All backflow prevention devices internal to the property boundary or downstream of a Water Corporation service (metered or otherwise that shall be located just within a property boundary) must comply according to the following plumbing standards: AS/NZS
3500.1:2003, AS/NZS 2845.1:1998, AS 2845.2:1996 and AS 2845.3:1993.
Note 2(a) A suitably rated backflow prevention device must be installed at the boundary based upon the maximum level of backflow risk assigned to the Customer’s property. Note 2(b) If the water service is 25 mm in size and the
Customer’s property is rated as a LOW form of backflow risk then a low rated form of backflow prevention must be installed, as a minimum, downstream of the service meter.
Note 2(d) Where testable mechanical valve type backflow prevention devices are installed, the isolation valve upstream of the line strainer and the isolation valve immediately after the device must be resilient seated.
Note 2(e) Where flow rate and/or pressure does not allow the use of a mechanical valve type backflow prevention device then refer to Note 3.An Air Gap (AG) / Break
Tank (BT) provides a low level form of backflow prevention protection. A Registered Air Gap (RAG) /
Registered Break Tank (RBT) provides a high level form of backflow prevention protection and is commonly used as an alternative form of low / medium or high level of backflow prevention protection in scenarios where flow rate and / or pressure becomes a possible operational issue to a Customer and / or
DFES (Department of Fire and Emergency Services)..
48

Plumbing Handbook

Note 4

Note 5

49

Except with the Corporation’s written authority, no branch or fitting shall be connected to a private service pipe within a distance of one meter on the consumer’s side of the Corporation’s stop-cock or water meter.
It is the responsibility of the licensed plumber to ensure compliant plumbing work internal to the private property boundary (see Note 1). Images shown in the diagrams on page 50 are for illustrative and informative purposes only. The Water Corporation does not acknowledge nor assume any responsibility or legal liability for any non-compliant internal plumbing work as required by the Plumbers Licensing and Plumbing Standards Regulations 2000.

Plumbing Handbook

Backflow Boundary Protection Diagrams

50

Plumbing Handbook

Contact Us

BuilderNet© is the most effective and efficient way of doing business with the Water Corporation.
Faults, Emergencies and Security

13 13 75

Building Services and
Subdivision Enquiries

13 13 95

Waterwise Helpline

13 10 39

Website
Email

24 hours www.watercorporation.com.au building.services@ watercoporation.com.au Lodgements by post:
Perth PO Box 100
LEEDERVILLE WA 6902

51

Plumbing Handbook

24 hours
8am - 5pm weekdays

Revisions
The following clauses in the handbook were revised on the dates shown Date

Description of Amendment

20 February 2012

Section 8.1 Protection of Services diagram amended

27 March 2012

Section 1.5 Sewer Connections added new connections
Section 1.7 As Constructed Plans (Flimsies) explanation added for ”Ins and Ups”
Section 2 Backflow Protection minor text change
Section 4.1 Disconnection from Water Corporation
Mains – Demolitions diagram amended due to change in design standard for installation of temporary builders standpipe Section 7.3 Metering. added paragraph regarding meter ownership Page 53 Contact Details removed Regional postal addresses Buildings Appendix note 2(a) text change

21 October 2013

Definitions - Added property sewer / sewer definitions

January 2014

Legislative references amended to reflect new act / regulations Handbook revised and reprinted

August 2014
September 2014
May 2015

52

Section regarding Boundary traps removed word property from beginning of sentence.
Section 7 and 7.2 relating to strata schemes amended

Plumbing Handbook

Similar Documents

Free Essay

Plumbing

...SUCCESS…………………………………………………………………..5 STARTING UP A PLUMBING BUSINESS………………………………………..6 PLUMBING BUSINESS PLAN……………………………………………………..7 OBJECTIVES…………………………………………………………………………8 SAMPLE OF COMPANY’S PLUMBING PLAN…………………………………..9 START UP REQUIREMENTS……………………………………………………...10 START UP FUNDING………………………………………………………………..11 MARKET ANALYSIS SUMMARY…………………………………………………12 SERVICE BUSINESS ANALYSIS……………………………………………………13 COMPETITION & BUYING PATTERNS…………………………………………..14 RISK INVOLVED………………………………………………………………………15 REFERENCES…………………………………………………………………………..16 plumbing INTRODUCTION Plumbing (from the Latin plum bum for lead as pipes were once made from lead) is the skilled trade of working with pipes, tubing and plumbing fixtures for drinking water systems and the drainage of waste. A plumber is someone who installs or repairs piping systems, plumbing fixtures and equipment such as water heaters. The plumbing industry is a basic and substantial part of every developed economy due to the need for clean water, and proper collection and transport of wastes. Plumbing also refers to a system of pipes and fixtures installed in a building for the distribution of potable water and the removal of waterborne wastes. Plumbing is usually distinguished from water and sewage systems, in that a plumbing system serves one building, while water and sewage systems serve a group of buildings or a city. The name of my small plumbing business is water tubes plumbing co. it is located at obehie, very...

Words: 3943 - Pages: 16

Premium Essay

Plumbing

...McPheeters Instructor’ Choice Assignment Fall2012-ECO2023-Princ Economics II-372686 November 3, 2012 Plumbing In my current position, I have the chance to dabble in many of your typical industrial trades such as electrical work, carpentry, welding and plumbing. As much as I enjoy this type of work, my job requirements create limitations to my knowledge and experience. I work in a maintenance capacity; therefore it is helpful to know a little bit about a lot, as opposed to being experienced in exclusively one trade. All of the aforementioned trades are suffering a shortage of qualified employees, so the opportunity exists to get into any of them and succeed, career wise as well as monetarily. It just amounts to how hard one is willing to work on what are generally considered unglamorous trades. For the purpose of this assignment I am going to focus on opportunities in the plumbing trade. Plumbers are tradesmen that are generally qualified for a wide range of responsibilities, and also need some experience in other trades such as carpentry and welding. Plumbers can handle jobs as simple as one man unplugging a toilet all the way to an entire company dedicating its workforce to constructing a skyscraper. They can handle everything from plastic pipe and glue to cast iron pipes and a welding rig. If they are working on a house, they would need some carpentry skills for plumbing installation. Plumbers have an advantage over some of the other construction related trades. With the...

Words: 706 - Pages: 3

Premium Essay

Plumbing Abuse

...When a plumbing emergency happens and you need to call a plumber The Colony TX, it may seem to strike out of the blue. The reality is, most plumbing emergencies started out as very small issues that either were ignored or flew beneath a homeowner's radar. Here are six common issues that people tend to ignore with their plumbing that can easily spiral out of control, given enough time. Fixing a Clog with the Wrong Tool When it comes to fixing plumbing issues, it is not one size fits all. For example, if you try to use a drain snake on a clogged toilet, you will significantly damage the toilet bowl. When it comes to clogged toilets, using a plunger first is always the safest bet. If the plunger fails, using an auger will usually do the trick....

Words: 491 - Pages: 2

Premium Essay

Hogan Plumbing Case

...Laser Plumbing The current legislative changes to GS 87-21 demand the Panel current recommended rules since it is created, to address the newest law. Locally owned and operated since 1987, TLC Plumbing is just a regional organization devoted to servicing the person desires of New Mexicans. In only 28 days, learn the most current techniques in the plumbing deal while generating a credential that employers will respect. If you want a plumber to abandon your needs for installations and repairs in the fingers of the pros at Morgan Plumbing. Level-2 can accommodate you if you've some pertinent plumbing and heating knowledge and skills, frequently from the part where you have been monitored. Plumbers applied at Bill Howe Plumbing have a number of specialties and certifications. B. Number five essential regional health rules linked to plumbing and inform how they guard safety and health. We're plumbing specialists, and are on-hand 24/7 to look after your outside or indoor careers. The Board renews endorsements for Multipurpose Residential Fire Protection Sprinkler Authorities Medical Gas Piping Installation and Water Supply Protection Experts. Then you've witnessed our exclusive red, warehouses-on-wheels service on their strategy to still another...

Words: 842 - Pages: 4

Free Essay

Installing Plumbing

...Feedmeseemoor GS1140 Installing Copper Pipes Problem: Install copper pipes for a new bathroom to run water to the toilette, sink and shower. 1. Prior to building the bathroom make sure that there is adequate accessibility to run copper pipes to the area where the bathroom will be located. 2. After bathroom is built and the configuration of toilette, sink and shower is complete make either a mental or written pattern of how you will connect the pipes. Remember you have hot and cold water. The sink and shower need both while the toilette needs only cold water. 3. Measure distances between toilette, shower and sink to have a general idea of how much copper pipe you will require. Always get about 10 feet extra just in case of a bad measurement or an adjustment in plan. 4. Drill 3 holes in wall near the toilette and sink to accommodate the shut-off valves: toilette gets 1 and sink gets 2. 5. Attach shut-off valves to 9 inch copper pipe segments and install so that valves are inside bathroom and other end is in the crawl space. 6. Attach copper pipe segments to shower on/off fixture so that the ends are in crawl space. 7. Measure copper pipe so that each segment connects with the corresponding hot or cold water shower on/off fixture or shut off valve. Make sure...

Words: 565 - Pages: 3

Free Essay

Pipes and Installation as It Affects Plumbing

...PIPES and INSTALLATION AS IT AFFECTS PLUMBING INSTALLATION SERVICES. Plumbing is generally refers to as a system of pipes and fixtures installed in a building for the distribution of portable water and removal of waste water. But in a wider scope, Plumbing installation services can be categorised into the following classes namely: * Cold & Hot water supply system: This is basically distribution of Portable water to building/buildings both internally and externally. * External Water Reticulation: This is water distribution network for a vast area of land. This could either be for a city, town, village, community or an Estate. * Soil & waste drainage system: This is piping system for the removal of both Soil waste from WCs and bidet and Waste water from WHB,K.S, and baths to be drained to a septic tank/soakaway pit, sewage treatment plant or public sewer. This also could be both internally or externally. * Rainwater system: This involves piping to remove rain water from building/buildings to be channelled to storm drain or external gutter. * Fire fighting system: This aspect of services is to combat any class of fire outbreak within and outside the building/buildings. It is also sub-divided into the following categories: a) Fire hose reel pipe installation - internal b) Dry & wet riser pipe installation - internal c) Sprinkler pipe installation - internal d) Fire extinguisher installation – internal & external e) Fire...

Words: 1949 - Pages: 8

Premium Essay

Summary of on the Meaning of Plumbing and Poverty

...Bryce Gray English 1103 Summary & Strong Response On The Meaning Of Plumbing and Poverty Summary In her essay “On The Meaning Of Plumbing and Poverty,” Journalist Melanie Scheller examines the cultural identity of the rural poor. The author brings the readers attention to her call to action about poverty in America while using facts and personal background. While caring for a woman in a psychiatric ward, Scheller witnesses the woman’s obsession for flushing the toilets in her unit. This memory creates an opportunity for her to write an essay about growing up in rural North Carolina. In the 1960’s the author was growing up with her mother and five other siblings, moving from place to place in search of a home where the rent was affordable. Scheller mentions how she lived in a house with five rooms, with one room in particular for her and her siblings to gather in to complete homework or watch television. Furthermore, Scheller describes how “in the South” of her childhood, if a family did not have indoor plumbing they were labeled as white trash and strongly stereotyped at school. They often had comments thrown at them such as “White-trash children had cooties- everybody knew that”(321). When Scheller is granted a college scholarship, she describes the feelings of happiness and delight she encounters when given the opportunity to use as many clean toilets and take as many hot showers as she wishes. Having this newfound privilege is a blessing but she is ashamed...

Words: 894 - Pages: 4

Premium Essay

Plumbing In The 1700s

...“Good, bad or indifferent, if you are not investing in new technology, you are going to be left behind”(Philip Green). This could be said about many things, especially the workfield. In a trade like plumbing there will always be newer and better technology to be invented. Plumbing originated during ancient civilizations the pipes were made out of lead. The original definition of a plumber was a lead worker, however the definition has changed over time. A plumber is a person who fixes or installs pipes of heating, sanitation and water supply systems. Water supply and sanitation was not as important in the 1700s as it is now, It took around 1,000 years to see any improvement of sanitation. With the growth of modern cities compacted with large...

Words: 354 - Pages: 2

Free Essay

Elkay Plumbing

...Managerial Accounting [pic] Case Analysis: Elkay Plumbing Vaughn, Reginald 1. Please comment briefly on the benefits of Time Driven Activity Based Costing (TDABC) Time Driven Activity Based Costing (TDABC) is a popular alternative to Activity Based Costing. First, Activity-based costing (ABC) should be defined. ABC is a costing methodology that identifies activities in an organization and assigns the cost of each activity with resources to all products and services according to the actual consumption by each. CIMA, the Chartered Institute of Management Accountants defines ABC as an approach to the costing and monitoring of activities which involves tracing resource consumption and costing final outputs. Resources are assigned to activities, and activities to cost objects based on consumption estimates. The latter utilizes cost drivers to attach activity costs to outputs. While ABC is considered a valuable tool for management, developing the model, calculating the bottom-lines, and testing the model once it is implemented is costly and arduous.  Managers are choosing TDABC because of the following benefits: • it can be easily updated to reflect changes in processes and resources costs • it captures the complexities of operations, it can be easily validated • it can be estimated and installed quickly • it identifies opportunities for process efficiencies • it is inexpensive to use ...

Words: 2072 - Pages: 9

Free Essay

Plumbers

...and can offer crucial consultation on the appropriate position of plumbing to make sure there is a good flow of water and waste in and out of the property. Among the many roles they play, plumbers can be called on to handle the following tasks: •Plumbing emergencies: clogged drains, Burst pipes and overflowing toilets are all circumstances that will necessitate an emergency call, before the situation turns into bigger troubles. Crisis plumbers are regularly on call 24/7 to offer round-the-clock support and repair. •Gas fitting: several plumbers also have gas fitting credentials, since two services are often linked. However, you need to make certain that your plumber holds the required gas fitting licenses and experience, since they vary between the two trades. •Toilets repair: Whether you want a toilet installation, fixed or maintained, a plumber will do it all. They will evaluate the pipes and fixtures to make sure the waste is removed from the property as it should be. •General maintenance: The most efficient and appropriate way to end small plumbing issues from escalating is to have your plumbing frequently maintained. Other than doing it yourself, it is highly advisable to hire a plumber who can comfortably look at backflow services, grease traps and the way your pipes operate and flow. •Gutters: Whenever your roof is leaking, chances are the guttering is the problem. A plumber can look into your roof plumbing system to ensure that it is able to handle tough rain and other...

Words: 336 - Pages: 2

Free Essay

Bouilding House Bedget

...Milestone | Description | Date | | Purchase Land | Tour land and lot. Secure loan. Purchase land. | 9/5/13 | | Secure permits. | Secure construction permits, septic tank permit, electrical permit, plumbing permit, and mechanical (HVAC) permit. | 9/6/13-9/10/13 | | Grade land and remove possible erosion sites. | Have a surveyor survey land and make suggestions regarding possible sites of land erosion or mass wasting. | 9/11/13-9/13/13 | | Laying the foundation and basement constructions | * Lay cement foundation. * Build basement foundation | 9/15/13-10/7/13 | | Framing the house & Deck construction | * Frame walls, roof and ceilings, including all door and window rough openings * Deck inspection | 10/8/13-11/1/13 | | Exterior walls, windows, and doors | * Apply exterior wall and roof sheathing. * Install windows and exterior doors | 11/2/13-11/15/13 | | Roofing | * Apply roofing and shingles | 11/16/13-12/15/13 | | Final exterior touches | * Apply exterior trim * Paint the house * Inspection of exterior | 1/1/13-1/10/14 | | Insulation & Drywal | * Install side insulation * Drywall laid * Inspection of drywall * Install ceiling insulation | 1/11/13-1/18/14 | | Plumbing, Electrical, HVAC | * Install plumbing * Install electrical wiring * Install HVAC * | 1/19/14-2/20/14 | | Appliances, Bathrooms, &Laundry Room | * Install appliancesInstall sinks, toilets, showers, etc. | 2/25/14-3/1/14 |...

Words: 256 - Pages: 2

Premium Essay

Drainflow: Repairing Jobs That Fail to Satisfy

...Repairing Jobs that Fail to Satisfy Contents Executive Summary 3 Introduction 3 Goal and Recommendations 3 Introduction 4 Background 4 Data Analysis 5 Job Structure and Organizational Design 5 Incentive Structure 6 Hiring Practices 7 Recommendations 7 Job Structure and Organizational Design 7 Incentive Structure 9 Hiring Practices 9 Strategy and Implementation 10 Conclusion 11 Appendix 12 1. Customer Survey 12 When Your Drain Won’t Go, Call DrainFlow 12 2. Original Survey 13 3. Sample Interview Questions for Interview Consistency 13 4. Financial Analysis 14 5. Current Process Map 15 6. Future Process Map 16 7. Current Org Structure 16 8. Proposed Org Structure 17 9. Peer to Peer Award Example 18 Executive Summary Introduction The report focuses on how DrainFlow can improve in three areas: job structure, incentive structure, and hiring practices. The main contents include an introduction to the problems DrainFlow is encountering, analyses of the current business, and recommendations on how DrainFlow can overcome these issues to foster a long-term competitive advantage. Goal and Recommendations The goal of this proposal is to provide recommendations for a new job structure, a new incentive structure, and new hiring practices. The job structure recommendations will allow for more cross training between office workers and service providers. This will enrich all jobs at DrainFlow by adding different tasks, autonomy...

Words: 5219 - Pages: 21

Premium Essay

How to Build a House

...The proper way to build a house By Jeremiah Archambault Homes today is what is needed in everyone’s existence, and range from being as simple as a tent or shelter of branches and leaves, and all the way up to a multi-story palace with several bedroom and bathrooms to your basic single story home. Whatever the structure may be it provides shelter and simplifies one’s life. Here are the proper steps involved to successfully construct a home. Selecting a location for your house has several items to consider before the construction begins. You should consider the climate, ground stability, availability of utilities, community infrastructure, and available building materials. When looking at the climate of the site one needs to make sure they are not in a flood plain, and also taking in to consideration of the temperature that the house will be built in whether it is intense heat to frigid cold. Ground stability is making sure that the soil is suitable. If the soil is mucky, shifting sand or other unstable earth will likely fall over a short period of time unless they are not built on special foundations or pilings. The availability of utilities is also important if you intend to have power, potable water, telephone and other conveniences, make sure these utility providers offer them at the location. The community infrastructure is also important to look at. Make sure good quality schools are available. Check to see if you are in a police jurisdiction to protect you from crime...

Words: 1084 - Pages: 5

Free Essay

Conceptualizing Business

... March 28, 2011 Conceptualizing a Business R.F.J. Plumbing, Inc. is a plumbing service company that provides plumbing services from installations, repairs, and new construction. We are committed to offering an excellent level of customer service. We want to provide this service with an intense passion and an achievement in which we take great pride. Every job assigned to us or that we acquire, we aim to deliver quality professionalism and skill. Our company’s primary goal is customer satisfaction with every job. We are totally committed to serving you better than any other company with our courteous, knowledgeable, and friendly service. That is what R.F.J. Plumbing, Inc. is all about! R.F.J. Plumbing, Inc. started in January 2009, with one employee and that employee was the owner. Since then we have grown to two employees and plan to continue this growth every 18-24 months. Through our high standards of professional performance, quality, commitment to perform as a team, and work ethics, we aim to continually improve our dedicated and amply skilled employees. We simultaneously maintain the important family orientation that reinforces the stability and future of each employee as we continue to grow. When starting a company one must consider the companies social and ethical responsibilities. Business owners must consider the entities that are important to the success of the business. R.F.J. Plumbing, Inc. has three major stakeholders. The stakeholders are Lowes Home...

Words: 1038 - Pages: 5

Premium Essay

Inters

...employees). SUMMARY OF DUTIES AND RESPONSIBILITIES The incumbent sets up gym area for sporting events and performs other related duties as assigned. Serves as assistant to a higher grade maintenance worker/mechanic in maintaining all equipment and facilities in optimum operating condition. Operates a mower, weed eater and other equipment as necessary to prepare and maintain athletic fields and related facilities. Assists in the performance of one or more trade practices associated with occupations such as carpentry, plumbing, electrical, air conditioning, painting, and other related trades that include general maintenance, repair and/or alterations to doors, floors, floor covering, walls, ceiling, windows, electrical switches, receptacles and light fixtures, commodes, wash basins and showers. Assists in performing repair of recreation/mess equipment and appliances and other related maintenance and/or custodial duties. Assists in the performance of simple plumbing repairs, light maintenance on air conditioning units, maintenance on equipment, and minor electrical repairs in the facility. Drives motor vehicles to and from work sites, warehouses, and dumps. Maintains maintenance shop in a safe and clean condition. Observes environmental, safety, security and housekeeping rules and regulations. QUALIFICATIONS a) Basic...

Words: 646 - Pages: 3