Project Description
Contractor Requirements: The contractor has obtained all licensing required to comply with all codes local and state as well as federal for the job proposed. The contractor has also proved that they are a licensed and authorized reseller of the networking and infrastructure components quoted throughout this agreement and can show proof thereof. The work will be supervised by a Registered Communications Distribution Designer (RCDD) during all phases of the installation. An RCDD must be onsite and available to technicians and installers any time the work is being performed.
The purpose of this RFP is to provide a functional specification for the comprehensive technology network system. This includes the required network cabling, termination points/boxes and necessary network devices. Mating sleeves, bare fiber adapters and optical attenuators are a few things that are needed specifically for fiber installation. In addition, the purpose would also include the proper details and criteria for the successful design of the network system. The contractor shall provide all of the necessary cables, network equipment and components necessary to construct the network system. This includes all raw materials such as cable, wall plates, outlet boxes, and such terminating modules and components as necessary to complete the job as contracted. Devices like test kits, power meters, fault locators, and connector adapters are all pre purchased and is property of the installing company. This document provides all of the necessary specifications to be used in the design of the network infrastructure and associated equipment. The contractor shall furnish all labor, materials, tools, equipment and reasonable incidental services necessary to complete an acceptable installation of the network infrastructure as contracted.
Business Case
Your network will be FTTB (Fiber to the Building). This means that the fiber will run to the main building and that will give you the ability to use fiber throughout the entire complex or the use of high-bandwidth copper cabling can be used. For the wired portion of the building and the telecommunications room, we will be using 62.5/125 cabling. Each room will have at least one outlet so anyone that needs a wired connection can do so and every room will have an extra drop that – if needed – is there for redundancy. This extra drop will be copper cat5e cable so that if anything goes wrong, you will still have a chance to connect to the internet. Since the building is pre-wired to use copper, you will have them for instances if any of your fiber network is damaged and needs time to fix/replace. It is much easier to install them now as opposed to when the building is occupied. Therefor each lab has an extra just in case you need to expand in the future.
If expansion is needed (other buildings on campus) you will have the proper connections ready so there will be no surprises when we come back to expand. The other buildings can be either copper or fiber (or a combination) or even wireless. Remember we can get higher bandwidth cat6 or 7 cable to prevent as much bottle-necking as possible.
As for the wireless portions of the network, we installed wireless access points in each of the theory rooms so anyone that needs to access the internet on their laptops or other wireless devices can do so without loss of signal strength. Wireless is much easier to upgrade or change in the future, so we are not installing the top-of-line wireless access point since most of the networking will rely on the stations in the rooms. The repeaters, though, can be adjusted to a different area (thanks to power over Ethernet). We will not charge labor for moving repeaters or access points, just our current service call price.
As for the four return drops that go from lab 1 to the telecommunications room, they each have a purpose also. Two drops are for load balancing and the other two are for the network printer and the last for redundancy.
Everything that we are installing is included in the price, we are not marking anything up. If we make a mistake that is not caused by Mother Nature or other contractors, we will fix it at no extra cost.

Goals and Objectives
Given the physical layout diagram, we will install 126 network drops based on EIA/TIA 568B, though not mandatory, we will follow the EIA/TIA developed FOTP's (Fiber Optic Test Procedures) and OFSTP-14 (Optical Fiber System Test Procedures) for testing. Also, the standards for optical power measurements are set by NIST (the US National Institute of Standards and Technology). We do need to comply with fire codes and will follow the NEC770 standard (this is the fire code for fiber). No deviation from the standards is permitted unless authorized by the proper authorities in writing.
The most important part of this whole project is safety. Working with fiber needs to be done in a clean environment due to the fact that if anything (dust, dirt, debris, etc.) gets in the cables or equipment, that can hurt or even make your network inoperable. All outlets, wiring racks, etc. will be supplied, installed, and tested by us. Our goal is to have everything up and functional well before it is needed to be sure to catch any errors. Equipment and components will honor any manufacture quality and performance warranties that they have. Any and all paperwork that is included with equipment will be left at the site for whom it may concern. Also included will be any notes or wiring diagrams needed to assist the head of whichever department is needed.
Our layout and routing of the cables will get network connectivity to every computer in the building that were are informed of, along with printers and servers. Please note that the printers will be connected to the computers via copper cat5e cable to help save a little money since it is not going to make anything faster/better when it comes to printing. The design of this network will give you many options to access different protocol methods.
If there is any work to be done during “off-hours” or if anyone runs into overtime, there will be no additional cost to you.
We will respond to any troubleshooting calls within, but no more than, 24 hours from receipt of said call. If it is critical, we will be on site within 4 hours of getting call.
Please be sure to reply with anything we may have missed, as we will only install and cover what is agreed upon in this bid. Project Team For this cable installation project our team will consist of three highly qualified, certified cable installation professionals. All team members have been trained in copper cable installation and have had much experience installing cable for large buildings (references available upon request). Our team will document the entire installation process to allow easy access for updating and troubleshooting and will demonstrate experience and competence in the field of copper cable installation. All employees have been trained and certified in proper installation and troubleshooting aspects of cable installation.

If your building was already in place (versus starting from scratch), there may be additional time needed to get everything set up. Also, that would change the architecture to FTTC or Fiber to the Curb. It may not be in the budget to run fiber to the building if it is not already there.

Similar Documents

Free Essay

Cabling Standards

...INTRODUCTION TO STRUCTURED CABLING Compiled by Sonam Dukda Division of Information Technology Ministry of Communication September 2000 TABLE OF CONTENTS 1 2 INTRODUCTION .......................................................................................................................... 4 NETWORKING ............................................................................................................................. 5 2.1 Objectives ................................................................................................................................ 5 2.2 Choice of Software and Hardware........................................................................................... 5 3 NETWORKING TRENDS ............................................................................................................. 6 4 STANDARDS................................................................................................................................. 6 4.1 International Standards ............................................................................................................ 6 4.2 Industry Standards. .................................................................................................................. 6 4.3 Structured Cabling standards................................................................................................... 6 4.4 Highlights of the EIA/TIA-568A standards.................................................

Words: 5055 - Pages: 21

Premium Essay

Homework

...Chapter 2: Cabling Specifications and Standards The Bottom Line Chapter 2: Cabling Specifications and Standards The Bottom Line Identify the key elements of the ANSI/TIA-568-C Commercial Building Master It 1. Which subsection of the ANSI/TIA-568-C standard would you reference for UTP cabling performance parameters? Answer: TIA-568-C.2 2. Which subsection of ANSI/TIA-568-C standard would you reference for optical fiber cabling and component performance parameters? Answer: TIA-568-C.3 3. What is the recommended multimode fiber type per the ANSI/TIA-568-C.1 standard for backbone cabling? Answer: 850nm (laser optimized) 50/125 micron multimode fiber 4. Which is typically a more expensive total optical fiber system solution; single-mode or multimode? Answer: Single-mode 5. The ANSI/TIA-568-C.1 standard breaks structured cabling into six areas. What are these areas? Answer: (1) horizontal cabling (2) backbone cabling (3) work area (4) telecommunications rooms and enclosures (5) equipment rooms (6) entrance facility Identify other ANSI/TIA/EIA standards required to properly design the pathways and spaces and grounding of a cabling system. Master It: Which other TIA standards need to be followed for: 1. Pathways and spaces? Answer: ANSI/TIA-569-B 2. Grounding and bonding? Answer: J-STD-607-A 3. Data Centers? ...

Words: 277 - Pages: 2

Premium Essay

Nt1230

...Chapter 2 NT1230 10/3/2014 1. When was the first major standard describing a structured cabling system released?      c. 1995 2. What doe EIA and TIA stand for?      i. EIA – Electronics Industries Alliance      ii. TIA – Telecommunications Industry Association   3. What are the three parts of the EIA/TIA 568-B standard?      i. EIA/TIA-568-B.1: Commercial Cabling Standard, Master Document      ii. EIA/TIA-568-B.2: Twisted-pair Media      iii. EIA/TIA-568-B.3: Optical Fiber Cabling Standard 4. Identify the six subsystems of a structured cabling system.      i. Building Entrance (Also called (EF) Entrance Facilities)      ii. Equipment Room (ER)      iii. Telecommunications Closet (Also called (TR) Telecommunications Room or (TE) Telecommunications Enclosure)      iv. Backbone Cabling      v. Horizontal Cabling      vi. Work Area 5. Which subsystem does permanent networking cabling within a building belong to?      i. Backbone Cabling 6. What is a cross-connect?      i. Cross-connect – A space where you are going to take one or multiple cables and connect them to one or more cables or equipment. 7. What is the main cross-connect?      i. Main Cross-Connect (MC) – Usually connects two or more buildings and is typically the central telecommunications connection point for a campus or building. It is also called the Main Distribution Frame (MDF) or Main Equipment Room. The MC connects to telco, an ISP, and so...

Words: 2096 - Pages: 9

Free Essay

Nt1310

...1. Application: Application is the term used within the Information Technology industry to reference software. The software can be for the end user which is known as the application software or it can be a Systems application software. 2. Unshielded twisted-pair: UTP, is also known as Category 5, and or Category 6. Consisting of 2 twisted pair of copper wire. UTP is the main type of cable used in LAN topography. 3. Shielded Twisted-Pair: Is similar to UTP, the main difference is that it is has an additional layer of shielding, this shield helps in preventing EMI, and other interference. STP is great application when a cable is being applied near power lines, metal pipes and is not in protected by plenum or conduit. 4. Fiber Optic Cable: Is a great long distance cable. There is Single mode, in which laser is transmitted and there is multimode, in which LED is transmitted. Both fiber cables are use to cover great distances up to allow data to traverse the fiber optic cable near the speed of light. 5. Dark Fiber is fiber optic cable is this idle and is not currently being used. 6. Coaxial Cable is an older cable that has a grounding copper core that is surrounded by a plastic protective insulating sheath, and then a protective grounding shield, and then there is the black outer protective plastic covering. 7. Plenum is a space or area that is intentional provided to allow for cables, pipes, tubing and other various plumbing. This space is typically...

Words: 932 - Pages: 4

Premium Essay

Physical Networking Unit 2 Assignment

...Physical Networking Unit 2 Assignment 1. The American National Standards Institute is a private non-profit organization that oversees the development of voluntary consensus standards for products, services, processes, systems, and personnel in the United States. The organization also coordinates U.S. standards with international standards so that American products can be used worldwide. For example, standards ensure that people who own cameras can find the film they need for that camera anywhere around the globe. ANSI accredits standards that are developed by representatives of standards developing organizations, government agencies, consumer groups, companies, and others. These standards ensure that the characteristics and performance of products are consistent, that people use the same definitions and terms, and that products are tested the same way. ANSI also accredits organizations that carry out product or personnel certification in accordance with requirements defined in international standards. 2. The Institute of Electrical and Electronics Engineers (IEEE, read I-Triple-E) is a non-profit professional association headquartered in New York City that is dedicated to advancing technological innovation and excellence. It has more than 400,000 members in more than 160 countries, about 51.4% of whom reside in the United States. IEEE is one of the leading standards-making organizations in the world. IEEE performs its standards making and maintaining functions through the...

Words: 1205 - Pages: 5

Free Essay

Cable Structure

...Fritz Dorcelus _ Physical Networking Cable Structure Week 3 assignment 1-What are the most common cables used today? Unshielded twisted-pair (UTP), shielded or screened twisted-pair (STP or ScTP), coaxial, and fiber-optic (FO) 2. Simply installing STP cabling does not guarantee that you will improve a cable’s immunity EMI or reduce the emissions from the cable. What are several critical conditions must be satisfied to achieve good shield performance? * The shield must be electrically continuous along the whole link. * All components in the link must be shielded. No UTP patch cords can be used. * The shield must fully enclose the pair, and the overall shield must fully enclose the core. Any gap in the shield covering is a source of EMI leakage. * The shield must be grounded at both ends of the link, and the building grounding system must conform to grounding standards (such as J-STD-607-A). 3. What are the distinct advantages of fiber optic? • Transmission distances are much greater than with copper cable. • Bandwidth is dramatically higher than with copper. • Fiber optic is not susceptible to outside EMI or crosstalk interference, nor does it generate EMI or crosstalk. • Fiber-optic cable is much more secure than copper cable because it is extremely difficult to monitor, “eavesdrop on,” or tap a fiber cable. 4. Cable bandwidth is a function of three interrelated, major elements. What are these major elements? Distance, Frequency, and Signal-level-to-noise-level...

Words: 1396 - Pages: 6

Free Essay

Twenty Organizations That Influence Cable Plant Implementation

...the members interested in developing a particular standard. b) ANSI standards include, SCSI interface specifications, programming language specifications, and specifications for character sets. c) ANSI helped to coordinate the efforts of the Electronic Industries Alliance (EIA) and the Telecommunications Industry Association (TIA) to develop ANSI/TIA/EIA-568, the cabling specification in the United States. 2) Electronic Industries Alliance (EIA) d) The Electronic Industries Alliance (EIA) was originally known as the Radio Manufacturers Association. Since then, the EIA has evolved into an organization that represents a wide variety of electronics manufacturers. e) The EIA is organized along specific product and market lines that allow each EIA sector to be responsive to its specific needs. These sectors include components, consumer electronics, electronic information, industrial electronics, government, and telecommunications. f) The EIA (along with the TIA) was the driving force behind the original ANSI/TIA/EIA-568 Commercial Building Telecommunications Cabling Standard. 3) Telecommunications Industry Association (TIA) g) The Telecommunications Industry Association (TIA) is a trade organization that consists of a membership of over 1,100 telecommunications and electronics companies. The TIA membership manufactures and distributes virtually all the telecommunication products used in the world today. h) TIA’s mission is...

Words: 1851 - Pages: 8