The basic aqueous layer separated previously was then transferred into a 250 mL beaker, and a 50 mL of HCl was collected in a 100 mL beaker. Using a pipette, HCl was slowly added to the basic aqueous substance to acidify it. The lab TA stated that the solution would turn cloudy once acidified, but this did not happen, despite more than 50 drops being added. When the pH was tested, it showed that the pH was definitely 1, despite the solution not being cloudy. The volume of the NaOH and HCl mixture
Words: 1452 - Pages: 6
For Liquid samples: 1. Put the liquid samples on slides. 2. Keep the slides overnight at room temperature or heat at 55-60oC for 1hr. 3. Stain with Erythrocin. (Keep slides inside beaker containing erythrocin for 20-25 mins) 4. Counter stain with Fast green. 5. Observe the slides under microscope. Erythrocin Stain 210ml Fast Green Stain 100ml Erythrocin 4g Fast Green 5g Acetone 20ml Glacial Acetic Acid 50ml Phenol 10ml Water 50ml Water 180ml Observations: At 1000x magnification, Cells observed
Words: 1497 - Pages: 6
FORTUNE -- It was a humiliating moment. Congressman Edolphus Towns was upbraiding a top Johnson & Johnson executive. Certainly Towns (D-N.Y.), the chairman of the House Committee on Oversight and Government Reform, has browbeaten his share of CEOs and Wall Street titans. But it's not the sort of thing that usually happens to J&J. At this hearing in May, though, Towns laid into the health care giant. "The information I've seen during the course of our investigation raises questions about the
Words: 3647 - Pages: 15
EQUIPMENT/MACHINES 1.0. General Machinery and Equipment 1.1. Weighing Scale 1.1.1. 1 g. sensitivity 1.1.2. 1 kg. sensitivity 1.2. Labelling machine 1.3. Coding Machine 1.4. Facility for washing and drying bottles 1.5. Measuring glasswares Laboratory apparatus including measuring glasswares, chemical supplies, filter paper 2.0. Additional Machine and Equipment needed for each dosage form: 2.1. Liquid/Suspension 2.1.1. Stainless Steel tank with stirrer of appropriate capacity 2.1.2. Jacketed
Words: 922 - Pages: 4
SAFETY AND LABORATORY RULES for ORGANIC CHEMISTRY LABORATORIES Explanatory comments may be found below under Standard Operating Procedures APPROVED SAFETY GOGGLES MUST BE WORN AT ALL TIMES. NO FOOD, DRINKS OR SMOKING ARE ALLOWED. SHOES MUST BE WORN. No bare feet or thong sandals are allowed. WORK IS PERMITTED ONLY DURING SCHEDULED LABORATORY PERIODS. Work is not permitted in other laboratory periods unless space is available and written permission is obtained from your instructor. NO OPEN
Words: 2503 - Pages: 11
A Johnson and Johnson Crisis Amanda Ferri University of Phoenix Darci DelTorto Tuesday, June 5, 2012 In 1955, McNeil Pharmacies introduced the first aspirin-free pain reliever for children and called it Tylenol Elixir. In 1959 when Johnson and Johnson acquired the brand, the medicine’s net sales were $11.4 million and by the following year the prescription only drug was approved for sale over the counter. In 1961, the sales of Tylenol kept rising and options for the drug kept growing and now
Words: 820 - Pages: 4
Steam Distillation is the process of distilling a mixture wherein one of the immiscible phases is a steam. It is a mild method for separating and purifying volatile liquid or solid organic compounds that are immiscible or insoluble in water. This technique is not applicable to substances that react with water, decompose on prolonged contact with steam or hot water, or have a vapor pressure of less than about 5 torr at 100°C. One way to perform steam distillation is through the live steam method
Words: 1056 - Pages: 5
so bad. It was never bad at all. It taught me to be versatile; to love what I do not; to take risks. And most importantly It let me be. Next crossroad, I did not practice what time has molded me to become. I’ve been certified to be a Clinical Laboratory Scientist but chose to take detour and be in the corporate. I chose to be in business. This major change made me independent. It made me bold, indomitable and proud. And
Words: 537 - Pages: 3
not the same as the ones that were validated then the whole process is in jeopardy of being shutdown by the FDA. This also would have a tremendous affect on the on-time delivery of the product to the customers. The strategic plan of Abbott Laboratories is to produce a quality product to the customers on time. This quality
Words: 1025 - Pages: 5
What are the pro’s and con’s of hair fiber evidence vs. other types of physical evidence?? Hair and fiber evidence can be serious to an investigation. In most cases, these alone cannot offer a helpful identification of a suspect, but these laboratory techniques can be helpful in narrowing down a list of suspects. When collecting hair evidence, it is extremely important to make sure that all hairs come from the same area of the body. This is because the physical characteristics of hair differ in
Words: 579 - Pages: 3