Photovoltaic Power Systems
Compiled by Tracy Dahl Overview
Photovoltaic (PV) technology converts one form of energy (sunlight) into another form of energy (electricity) using no moving parts, consuming no conventional fossil fuels, creating no pollution, and lasting for decades with very little maintenance. The use of a widely available and reasonably reliable fuel source—the sun—with no associated storage or transportation difficulties and no emissions makes this technology eminently practicable for powering remote scientific research platforms. Indeed, numerous examples of successfully deployed systems are already available. The completely scaleable nature of the technology also lends itself well to varying power requirements–from the smallest autonomous research platforms to infrastructure-based systems. This technology can be limited, however, by annual fluctuations in solar insolation, especially at extreme latitudes. Based on semiconductor technology, solar cells operate on the principle that electricity will flow between two semiconductors when they are put into contact with each other and exposed to light (photons). This phenomenon, known as the photovoltaic effect, was first discovered by Edmund Becquerel in 1839. Actual development of PV technology began in the 1950s and gained greater impetus through the NASA space program during the 1960s. Research continues today at national laboratories and within private industry, focusing on increasing conversion efficiencies and mass production strategies to further lower the cost of producing PV modules. For a list of some of the many online resources on PV technology visit the Links Section of http:// polarpower.org. The same web site offers presentations from the 2004 Renewable Energy Working Group Meeting and links to the Autonomous Systems in Extreme Environments Workshop report under News > Past Meetings.

Cost
Since the first PV panel was developed in 1954 at a truly astronomical cost, the efficiency of solar cells has risen steadily. At the same time, prices have fallen consistently from $70 a watt in the 1970s to less than $4 a watt today. (Note that this cost does not reflect the total system cost, which will vary widely based on the application.) Despite the remarkable reduction in price over the past several decades, PV technology remains somewhat expensive at $4 a watt ($4,000 per kilowatt). However, if one takes a lifetime-cost approach, PV looks much more favorable: There is no cost for fuel, very little maintenance is required, and PV panels have an estimated lifetime of more than 30 years. When these factors are taken into account, the real price of 1 kilowatt of PV is roughly $133.

Design Requirements
Many factors must be considered when designing any remote power system. The biggest overriding factor is that all systems, regardless of the power source, should make energy conservation a top priority. Simply put, the less power needed, the lesser the amount that must be produced and stored. This can reduce the size, cost, and weight of the system dramatically. There are many strategies that can be used to reduce the total amount of electrical power required to perform a given task. For a more comprehensive discussion of this subject, see the “Efficiency” section further on in this document. To enable you to determine the optimal PV system size for your chosen application, system sizing worksheets follow at the end of this document.

Photovoltaic Power Systems Technology White Paper

1

Components
PV Panels
PV panels tend to work much better in cold weather than in hot climates (except for amorphous silicon panels). Add a reflective snow surface and the output can sometimes exceed the rating for the panel. Array currents up to 20% greater than the specified output have been reported (1). In general, PV materials are categorized as either crystalline or thin film, and they are judged on two basic factors: efficiency and economics. For remote installations where the actual space available for PV panels is often quite limited, the greater conversion efficiency of crystalline technology seems to have the advantage. It is also worth noting that the conversion efficiency of thin-film panels tends to drop off rather rapidly in the first few years of operation. Decreases of more than 25% have been reported. This performance deterioration must be taken into account when sizing the array for a multi-year project. However, there are still applications where the lighter weight and greater flexibility of the thin-film panels may be more suitable. Which PV technology is more appropriate for a given application will need to be determined on a case-by-case basis. Monocrystalline silicon panels should be utilized when a higher voltage is desirable. This would be in an instance where the DC power has to travel some distance before being utilized or stored in a battery bank. These panels are also the most efficient PV technology, averaging 14% to 17%. New technology charge controllers, which allow for a higher array voltage than the battery bank voltage, somewhat obviate the advantages of the monocrystalline panels. Polycrystalline silicon panels have efficiencies of 12% to 14% and can often be purchased at a lower cost per watt than monocrystalline silicon panels. This type of panel sees the widest use in polar applications.
Monocrystalline PV panel

Thin-film technologies include amorphous silicon, cadmium telluride, copper-indium diselenide, and others. Although the cost of these panels appears attractive at first, it is important to note that the efficiencies are comparatively low. The 8% to 10% efficiencies Polycrystalline PV panel seen in new panels quickly degrade to about 3% to 6% after several months of exposure to sunlight. Furthermore, amorphous silicon and cadmium telluride modules are sensitive to a much narrower band of colors, and the winter shift to redder sunlight results in slightly poorer performance (2). Newer, triple-junction thinfilm technologies appear to have higher efficiencies and less degradation over time, but they are still subject to the same problems mentioned above, if to a lesser degree. The somewhat flexible nature of thin-film technology may make it appropriate for some applications, but in general, the higher efficiencies and more robust nature of the crystalline silicon modules make them a better choice for polar applications. Regardless of the technology employed, the researcher would be well advised to look for modules with heavy-duty aluminum frames, UL ratings, easy-to-use junction boxes, and a long warranty (20+ years). All of these are indicative of a quality unit that will withstand the rigors of the polar environment.
Thin flim PV panels

Photovoltaic Power Systems Technology White Paper

2

Images courtesy of Solar Energy International.

Photovoltaic Power Systems Technology White Paper

3

Batteries
The principal problem to overcome with any PV system is that the sun does not shine on every part of the planet with equal intensity. This uneven availability of solar energy is greatly exacerbated in the Polar Regions. Daily and annual fluctuations in solar insolation necessitate storing excess energy for later use. Batteries are the technological solution most commonly employed for this purpose, but other energy storage mediums do exist. Fossil fuels and combustion generators can be used to provide on-demand power. Dynamic flywheels have been successfully utilized in several larger systems to kinetically store energy. On-site production and storage of hydrogen as an alternative fuel source holds great promise but is not quite ready for prime time as of this writing. All of these means are dealt with in greater detail elsewhere in this web site. For now, batteries provide the most cost-effective solution for energy storage for small- to medium-sized autonomous power systems. A battery stores electrical energy in the form of chemical energy. For a PV-battery system to function effectively, the electrochemical processes must work in both directions—in other words, the system must be rechargeable. To this end, batteries perform three main functions in a stand-alone PV system: 1. Autonomy–by meeting the load requirements at all times, including at night, during overcast periods, or during the winter when PV input is low or absent. 2. Surge-current capability –by supplying, when necessary, currents higher than the PV array can deliver, especially to start motors or other inductive equipment. 3. Voltage control–thereby preventing large voltage fluctuations that may damage the load (3). Any battery suitable for PV applications will be a deep-cycle type of battery as opposed to a starting (SLI) type. Although these two fundamental classes of batteries may appear similar on the outside, the internal structure is quite different. SLI batteries are intended to deliver a high-amperage output for a short period of time, but repeated deep discharges cause rapid deterioration of battery performance. These batteries are typically rated in cranking amps, or cold cranking amps (CCA). Deep-cycle batteries are designed to deliver a typically lower current for the size of the battery, but they are capable of withstanding numerous deep discharges without damage. The amount of energy a deep-cycle battery can store is referred to as its capacity. The unit that describes capacity is the amp hour (Ah) . Battery capacity is determined by the manufacturer based on a constant discharge over a period of time. Oftentimes, batteries will appear to have multiple ratings due to this rating process. The 20-hour rate (C/20) and the 100-hour rate (C/100) are referred to most frequently. When determining which battery to choose, be sure to compare all batteries at the same discharge rate. Deep-cycle batteries vary widely in type, price, and quality. Low-cost trolling batteries represent the low end of the scale and are generally not suitable for use in remote power applications. The most expensive battery per amp hour is generally the gel-cell battery. Battery failure has often been the cause of suboptimal power system performance. Without a doubt, this is not the area to cut expenses. The battery bank for any power system must be of the highest quality available, of the correct type for the application, and of sufficient capacity to ensure that the depth of discharge does not exceed design parameters. The size of a battery bank for even relatively low-power applications can be surprisingly large, particularly if year-round autonomy is a design requirement. Cold temperatures reduce capacity but tend to extend battery life. System sizing worksheets (see the end of this document) are essential for ensuring adequate battery capacity for a given project. The most common type of battery found in PV systems is the lead acid battery. Although the discussion will focus on this blanket technology, other rechargeable battery types do exist, including nickel-cadmium (NiCad), nickel metal hydride (NiMH), nickel-iron (NiFe), lithium ion, and lithium polymer batteries. Of these, the NiMH and lithium polymer batteries show significant promise for broader application in autonomous power systems. These battery types demonstrate up to a four-fold greater energy density and enhanced performance across a wider temperature range, which might ultimately favor this emerging technology. NiCad batteries have been used in a few polar applications, as they have superior performance in extreme cold. However, the high price, low efficiency (about 65%

Photovoltaic Power Systems Technology White Paper

4

vs. 85%-95% for lead acid), and restrictive charging parameters make them unsuitable for most applications. At the moment, the comparatively low prices and well-documented performance of lead acid batteries favor their continued use for remote power systems. In the lead acid class of batteries, two specific types stand out for their applicability to polar power applications: the gel cell and the absorbed glass mat (AGM). These two types of batteries represent good choices not only due to performance characteristics but also because they are both suitable for air transportation. Because the electrolyte solution in both of these battery types is immobilized, they represent a lower hazard class than standard flooded batteries and do not require a great deal of specialized packing before being shipped via aircraft into the field. Although the performance characteristics of flooded deep-cycle batteries Deka AGM type battery may meet or exceed those of the gel-cell and AGM types, the transportation and maintenance issues can prove to be quite problematic. Both of these types of batteries are classed together as valve-regulated lead acid (VRLA) batteries. A battery charging at a high amp rating or an excessively high voltage can release gases (hydrogen and oxygen) due to an overcharge condition. In a VRLA-type battery, gases are not released during a normal, controlled charge cycle. There is a closed loop that keeps the chemical levels balanced and internal pressures below the release threshold of the valve. One very important difference to note between gel-cell and AGM batteries is that the gel-cell battery is a platelimited design, whereas AGM batteries are an electrolyte-limited design. This can be very important in polar applications where extremely cold temperatures are often the norm. Freezing the electrolyte solution in a battery must be avoided. It causes irreversible damage to the battery, which could lead to catastrophic failure. Also, a frozen battery cannot recharge until it has been thawed out again—not always a simple proposition in the field. Electrolytes freeze at higher temperatures as they discharge and the specific gravity decreases. AGM and floodedcell batteries can continue to discharge until the electrolytes become severely depleted, resulting in a low specific gravity and a relatively high freezing point. A quality load controller somewhat obviates this concern, as it will typically incorporate a low-battery disconnect capable of opening the circuit between the battery and the load prior to the onset of problems. In a plate-limited battery, the chemical reaction that causes the flow of electrons ceases before the electrolyte specific gravity falls too low. This provides a certain measure of inherent protection by design. Similarly, gel-cell batteries can recover more easily from a deep discharge due to the fact that they can more readily accept a charge when energy from the PV array once again becomes available. For small, low-current solar systems, gel-cell batteries seem to be the best choice. It is important to note, however, that gel-cell batteries are vulnerable to damage in other ways. Charging at excessively high rates can create voids in the gelled electrolyte that significantly reduces the capacity of the battery. Voltage and current must be carefully controlled and cannot exceed the C/20 rate (approximately 5% of the amp hour rating for the battery bank). For larger systems that incorporate other charging sources such as wind turbines or engine generators, AGM batteries may be preferable

Liquid Electrolyte Freeze Points, Specific Gravity, and Voltage State of Charge Freeze Point Specific Gravity Voltage 100% 75% 50% 25% 0% -71º F -35º F -10º F 3º F 17º F 1.260 1.237 1.200 1.150 1.100 12.70 12.50 12.30 12.00 11.70

* Adapted from Photovoltaics Design and Installation Manual (2004), SEI.

Photovoltaic Power Systems Technology White Paper

5

due to a superior high-current rate performance (4). It is worth noting that many battery manufacturers offer both gel-cell and AGM types. Gel-type batteries have fallen somewhat out of favor in the industry in recent years, but there are still applications where this is the most appropriate technology to use. The optimal battery choice for a given research project must be determined on a case-by-case basis. Battery capacity is dramatically affected by the cold. Capacity is reduced by 50% at -10º F, and the risk of freezing becomes much greater. At the same time, battery life is increased by 60% due to a lower rate of self-discharge and generally depressed chemical processes. This applies to all types of lead acid batteries and explains the phenomenal service life of some batteries deployed to polar environments. The reduced capacity must be taken into account when determining the battery bank size required for a system.

Temperature (F) vs. Capacity

The depth of discharge (DOD) also has a direct bearing on how long a battery will last. A battery discharged to 50% on each cycle will last about twice as long as one discharged to 80% per cycle. This is a major issue for polar researchers wishing to run PV-powered experiments over the length of a polar winter when little or no solar insolation is available to recharge the battery bank. Between reduced capacity due to cold temperatures and longevity issues related to the DOD, this type of system will typically require either a very large battery bank or an alternative charging source, such as a wind turbine or engine-driven generator. When diagnosing battery problems, be sure to differentiate between the surface charge and the actual state of charge. A battery still connected to the PV charging source may appear to have adequate voltage, but this can be very misleading. When analyzing a battery, first disconnect it from the charging source and allow it to sit for an hour before taking a baseline voltage measurement. Next, hook it up to a dummy load, which should be a resistive load. Watch the battery over a period of time and observe the voltage decline. If it drops dramatically right away or maintains voltage for a short time before the bottom drops out, the battery is bad. Generally speaking, it is poor economy to replace only one battery or cell in a battery bank. As with any interconnected system, the performance tends to be reduced to the level of the poorest performing module.

Photovoltaic Power Systems Technology White Paper

6

Image courtesy of Solar Energy International.

Photovoltaic Power Systems Technology White Paper

7

Image courtesy of Solar Energy International.

Photovoltaic Power Systems Technology White Paper

8

Charge Controller
Regardless of the battery type chosen for a particular system, a charge controller remains an essential component. The primary function of a charge controller is to prevent the battery bank from being overcharged when there is abundant solar insolation available. Overcharging a battery can lead to electrolyte imbalances and depletion. In cases of severe overcharging, batteries can be completely destroyed along with any instrumentation in the vicinity. There is a wide range of charge controllers available, and the design requirements of the system dictate which charge controller should be utilized. The maximum charge rate is the first parameter to consider along with the system voltage. The amp rating of the charge controller should be oversized by a minimum of 25% for enhanced reliability. Greater functionality will be required for more complex systems and those that are deployed year-round. Charge controller functions include the following: 1. The simplest charge controllers really only perform the overcharge protection function. It is essentially an on/off switch for the PV panels. They are typically sealed units and cannot be re-set to account for variations in battery type. Nevertheless, the simplicity and sealed nature of these controllers makes them quite appropriate for low-power, summer-only applications. 2. The next level of sophistication allows for changing the charge parameters. For instance, the voltage level can be set to accommodate the differences between flooded-cell, gel-cell, and AGM-type batteries. 3. Temperature compensation is critical for polar applications. Essentially, at colder temperatures, voltages must be increased to achieve the same state of charge. At –40º C, a temperature-compensated charge controller will run about 2.74 volts per cell (16.4 volts in a 12-volt nominal system) to maintain a 100% state of charge. At 50º C, the same temperature-compensated charger would run 2.3 volts per cell (13.8 volts) to maintain a 12-volt battery at a 100% state of charge. Some charge controllers have this functionality built into the circuit board, whereas others use a remote sensor.

This graph shows the importance of temperature compensated charge control. As temperatures decrease, charging voltages must be increased.

Photovoltaic Power Systems Technology White Paper

9

4. The next level of functionality involves multi-stage charge control, most typically bulk, absorb, and float levels This allows for a high current rate during the bulk stage, which then tapers off current as the voltage rises into the absorb level. The float stage reduces voltage to prevent excessive gassing and is really meant as a trickle charge to keep the batteries fully topped off. For battery longevity, it is critical that the float level is reached and maintained for fairly long periods of time. 5. Some charge controllers can also function as load controllers, or they can function to send excess energy to a diversion load. As a DC load controller, the function is typically to serve as a low-voltage disconnect. This allows the battery bank to be protected from overdischarge as discussed previously. When used in the diversion control mode, excess energy that would otherwise be wasted when the battery is full is instead routed to a dump load, most typically a resistive air or water heater. This can be a very important function in polar environments where heat is usually a useful energy source. Note that most charge controllers with these capabilities can still only operate in one of the three modes—either as a charge controller, diversion controller, or DC load controller. Multiple controllers may be required. 6. Pulse width modulated (PWM) chargers sense small voltage drops and react by sending out short charging cycles. This can occur many times per minute. It allows for more accurate charging at the float level and tends to reduce sulfation of batteries kept at float for long periods of time. 7. The latest generation of charge controllers incorporates a technology called maximum power point tracking, or MPPT. This function is designed to increase the efficiency of the PV array by converting the typically higher voltage (17-21 VDC in a 12 VDC nominal system) to the 14 VDC or so required to charge the battery. Stated simply, the un-useable high-end voltage is converted to useable extra amps. Remember the relationship between volts, amps, and watts: watts = amps x volts. An MPPT charge controller takes advantage of this relationship to deliver more useable power from the PV array to the batteries. The electronics utilized to make this work are quite sophisticated, however, and the price of the controller is consequently much higher. At the moment, there are only a few MPPT charge controllers available. However, because the benefits are quite obvious and quantifiable, there will no doubt be several more showing up on the market, and prices should start to come down. 8. Finally, some high-quality charge controllers allow for a higher array voltage than the system voltage. For instance, a PV array can be wired for a 48 VDC nominal output to feed a 24 VDC nominal battery bank. The advantage of the higher array voltage is that significantly smaller conductors can be used without incurring unacceptable voltage drops. This can be an important consideration if the PV array needs to be set some distance away from the battery bank due to site or project requirements. For a look at relative conductor sizes and current carrying capacities, see the chart in the section on conductors below. Note that higher array voltages also pose a greater shock hazard. It is nearly impossible for a person to be shocked by a 12 VDC nominal system (although sparks will still fly if an un-insulated positive lead comes in contact with a grounded component) in contrast to a 48 VDC nominal or higher system. The open-circuit voltage on a 48-volt PV array is typically more like 80 to 90 volts and is quite capable of delivering a shock. If relatively untrained individuals will be setting up or servicing the system, it may be prudent to stick with 24 or lower voltages for the system. In conclusion, select a charge controller that meets or exceeds the requirements of the system. It may not be necessary to spend hundreds of dollars on a charge controller if the needs of the system are quite basic. Also consider that the liquid crystal displays (LCD) usually found on high-end models will likely be inoperable and may even crack at extremely low temperatures.

Photovoltaic Power Systems Technology White Paper

10

PV Array Mounts
On a clear day at solar noon, about 1,000 watts per square meter will fall on a surface placed perpendicular to the sun. If that surface is a PV panel working at 10% efficiency, the solar energy will be converted into 100 watts of electrical power. The PV array functions to securely mount the individual PV panels and maximize the conversion efficiency as much as possible by maintaining the orientation perpendicular to the sun. There are two basic types of arrays for mounting PV panels: fixed and tracking. Tracking arrays can move in one or two planes and can employ active (motor drive) or passive mechanisms for following the course of the sun. In high latitudes, dual-axis trackers can increase the output of an array by up to 60% in summer applications, yet they are rarely employed for mission-critical applications such as autonomous instrument platforms. The reason is reliability. To date, no automated tracking system has proven to be robust enough to withstand polar weather conditions. Until such tracking mechanisms are more reliable, the power budget is better spent on obtaining more PV modules on a fixed array. If a researcher really needs to make maximum use of the summer sun, multiple arrays or multi-sided arrays can be constructed to take advantage of the longer day. In the wintertime, any benefit from pointing the array toward anything but the equator is negligible. Therefore, for most year-round applications, a fixed array pointing south in the northern hemisphere or north in the southern hemisphere is the best bet for a reliable and efficient arrangement. Because polar areas tend to have very high magnetic declinations, be sure to correct compass readings or use a GPS to obtain a true bearing. Note: If a site is continuously occupied, manual tracking of the sun is another option that is reliable and can dramatically increase the output of the array. Manual tracking arrays have been successfully deployed at Lake Hoare, Antarctica.

Array Orientation
As alluded to above, maximum output from a PV panel is achieved by pointing the surface directly at, or perpendicular to, the sun. The relationship between the angle of beam radiation and the plane of the panel surface is called the angle of incidence. Conversion efficiencies and therefore the electrical output are highest when the angle of incidence is zero. Two angles determine the orientation of the PV array: the tilt angle and the surface azimuth area.
Image courtesy of Solar Energy International.

Photovoltaic Power Systems Technology White Paper

11

In the real world, the ideal orientation can seldom be achieved for a single day, much less for an entire year. Array orientation always involves a compromised solution, usually determined by site constraints and system requirements. Note that although in certain situations (e.g., solar noon on a clear day on a polar ice cap in mid-summer) a PV panel will produce more than the rated output of the unit, there will more typically be factors that reduce the actual output from the rated output. An angle of incidence greater than 0º, atmospheric conditions, snow on the panels, and so forth will all reduce output. Generally speaking, the rated output of a PV panel mounted on a fixed array can only be obtained for around five hours on even the best solar day. Output drops off on either side of the solar window but can still add significantly to overall energy production. It is a common misconception that because there is 24 hours of daylight during the polar summer that this equates to 24 hours of maximum production. If at 1 a.m. the sun is shining on the backside of the panels, there is little or no electrical output. This all must be taken into consideration when designing the system.

Image courtesy of Solar Energy International.

Remember, too, that sunlight becomes scattered by the earth’s atmosphere and is reflected from surfaces. As anyone who has experienced the albedo of an overcast day on snow-covered surfaces can attest, the light comes from many directions, not just in a straight line from the sun. Reflected light can definitely enhance PV panel performance and is an asset that polar researchers can utilize with great efficacy. Some work has been done on utilizing reflectors at the top of PV panels to enhance the reflected light capture for low-angle, winter applications. The total solar radiation striking the surface of the PV panel is what ultimately determines electrical output and is the sum of direct-beam radiation, diffuse radiation, and ground-reflected radiation. Insolation refers to the energy contained in the sunlight striking a surface area over a specified period of time. Solar insolation is therefore the prime criterion in determining the suitability of a location for PV applications.

Photovoltaic Power Systems Technology White Paper

12

Image courtesy of Solar Energy International.

Additional factors that should be taken into consideration for orienting solar arrays include the following: Panel orientation should be optimized for summer-only, winter-only, or annual energy production. At the equator, there is essentially no significant variation in the angle of the solar radiation striking the surface. The higher the latitude, the greater the difference between the optimal angles for summer and winter production. For summer-only applications, low tilt angles tend to increase energy production. Winter-only applications should utilize high tilt angles. In the Polar Regions, so much more energy is available in the summer months that lower tilt angles will maximize annual energy production; however, battery banks can seldom be adequately sized to store all of the electrical energy produced. Utilizing a lower tilt angle in areas that experience heavy overcast can often significantly increase summer production. Although the utilization of direct-beam radiation is decreased, this orientation allows the panel to see more of the sky over a longer period of time. A summer-only application in interior Alaska is an example of a site that might maximize energy production by utilizing this strategy. PV arrays have been successfully deployed on structures located on the annual sea ice around McMurdo Sound, Antarctica, by securing them flat against the roof. An additional advantage is that there is much less surface area exposed to the wind, and the typically dry snow easily scours from the surface. Use caution, however, as wet snow can pose significant accumulation problems for flatmounted panels. Overcast conditions coupled with snow-covered surfaces can result in high albedo, in which case a higher tilt angle will perform better because it can capture reflected light from the white surface. Vertical orientations can perform quite well at high latitudes and can sometimes represent an excellent compromise for year-round applications, particularly on permanently snow-covered (highly reflective) surfaces. Snow has a very hard time sticking to vertical surfaces. Simple tripod array mounts have been used with success on the Greenland Ice Cap and elsewhere. Pointing panels at different azimuth

-

-

Photovoltaic Power Systems Technology White Paper

13

For large, infrastructure-based systems, building integrated PV offers an architecturally interesting and cost effective solution. Pictured here is the Kyocera Headquarters in Kyoto, Japan.

Image courtesy of Solar Energy International.

Photovoltaic Power Systems Technology White Paper

14

angles can increase production over the course of a 24-hour period. As an example, see the article on the Camp Raven Renewable Energy system. (http://polarpower.org under Examples > By Location > Greenland) Is this a manned, summer-only application? If so, the tilt angle should be adjusted weekly to maximize the collection of solar energy. A quick and easy way to make on-the-spot adjustments is to place an object such as a pencil or a ruler perpendicular to the module face at solar noon. If it is a clear day, the object will throw a shadow. Now simply adjust the panel until the shadow disappears, and the panel will be oriented perpendicular to the sun. Is this a high snow load area? If so, more vertical orientations may be required to keep the panels from being covered (effectively shaded) by snow. Also, the array must be a sufficient distance from the ground to prevent burial by snow accumulation, either from direct accumulation due to snow sliding off the front of the panels or from drifting snow conditions. Is this a high wind area? If so, then it is essential to thoroughly secure the array. By design, PV arrays present a lot of surface area for the mass of the unit. This creates a very effective sail. Substantial frames and bases are critical components to ensure that the array can survive the stresses of high wind conditions. Additional guys can be attached to earth anchors suited to the array location. This aspect of a deployment cannot be overemphasized. Every other aspect of a system design can be flawless, but if the entire thing blows away, it is all for naught. This has all too often been the case with systems deployed to polar environments. Will there be animals in the area that might damage equipment? This is a concern more unique to the Arctic where curious indigenous creatures large and small have had detrimental effects on research projects. Typically, if a system is robust enough, that is an adequate solution in and of its self. In deployments experiencing particularly high incidents of damage from animals, more proactive measures may be called for. These can include audible alarms set off by motion detectors or even electric fencing. Remember that these devices will place an increased demand on the power system and must be accounted for in the power balance.

-

-

-

Generally speaking, for a year-round PV system in polar environments, setting the tilt angle at latitude or latitude minus 10º is a pretty good rule of thumb. However, there are obviously many factors that must be considered when determining the best solution for mounting and orienting a PV array.

Inverters
An inverter is a device that converts DC power from the battery bank to AC power for various loads. In smaller PV systems, it may be possible to eliminate this component altogether. In larger systems incorporating components that demand AC power, an inverter must be utilized. Also, if the instrument site is located some distance from the power production site, an inverter allows for an efficient means of getting electricity to the point of use. Alternating current is easier to transport over long distances and has become the conventional modern electrical standard. There are two fundamental categories of inverters: synchronous and static or stand-alone. Synchronous inverters are capable of being tied into the electrical grid, or utility power. Except in the largest of infrastructure-based systems, this type of inverter finds little application in the field of polar research. Static inverters are designed for independent, utility-free power systems and are the type most often used for remote PV applications. A second inverter classification refers to the type of AC waveform they produce. Inverters are available in square wave, modified square wave, and sine wave outputs. Square wave inverters are inexpensive, but they typically provide poor output voltage control, limited surge capacity, and significant amounts of harmonic distortion. In general, this type of inverter is inappropriate for remote scientific research applications.

Photovoltaic Power Systems Technology White Paper

15

-

Modified square wave inverters utilize more complex circuitry to create a wave form more closely approximating a true sine wave. They are capable of handling greater surge loads and have an output with less harmonic distortion. Although capable of powering a wider range of loads, there are still issues of concern for the polar researcher. Some electronic devices can pick up inverter noise, or buzz, and any device utilizing a digital timekeeper will run either fast or slow when powered by a modified square wave form. Sine wave inverters are best for powering sensitive electronics that require a high-quality wave form. They have little inherent harmonic distortion and typically have surge capacities of double or greater the continuous output rating. This is an important consideration if motors or other inductive loads are part of the overall power budget. Because sine wave inverters are now available in sizes from a few hundred watts to many kilowatts of output, there is little reason to consider any other type for polar research applications. Note: If AC power is part of the project requirement, use an inverter with a high-quality sine wave output.

-

When selecting an inverter, many additional criteria must be considered: DC voltage input must match the battery voltage of the system. AC power output must be adequate to satisfy the maximum-potential combined AC load, or all of the ACpowered equipment that might be on at one time. However, the system designer should also be cautious about over-sizing the inverter, as most operate at their maximum efficiency toward the middle to upper end of their output range. Voltage and frequency regulation should be very tight in a high-quality unit. Voltage and frequency should match the system requirements (60 Hz/120 volts for U.S. equipment and 50 Hz/240 volts for European equipment). Note that step-up or step-down autotransformers can be utilized to change output voltages if required but at the expense of slightly more power consumption. Efficiency should be high across a broad range of output levels. Some inverter manufacturers claim high efficiency levels, but they may be measured at or near maximum output where the inverter will rarely operate. Choose an inverter rated for high efficiency over a wide range of load conditions. Construction should be consistent with the application requirements. Some inverters offer a sealed design or special coatings on the electronics to enhance reliability in wet or corrosive environments. Other inverters utilize open construction with a cooling fan for increased load capacity. A limited range of marinerated inverters is available for maritime environments.

-

-

-

Balance-of-System Components
We have now discussed all of the major components that form a PV system. Still, there are many more bits and pieces required before proceeding from boxes of parts to a completed system.

Conductors
PV systems always incorporate DC circuits and often utilize an inverter for AC circuitry as well. AC and DC wiring systems have distinct requirements and should never be mixed in conduit, raceways, or junction boxes. DC systems are typically low voltage (< 48 VDC) and thus require much larger wire sizes than AC systems. Indeed, the wire size required to avoid unacceptable voltage drops across any distance or in high-current applications is often surprisingly large. Many systems have experienced poor performance due to inadequately sized conductors. The polar environment introduces additional challenges in system wiring. Larger cables used for battery connections become incredibly stiff and difficult to work with due to the insulated sheathing. Coarse-stranded wire

Photovoltaic Power Systems Technology White Paper

16

intended for residential AC-type use exacerbates the difficulty. Pre-assembling as much of the system as possible will reduce field installation woes. However, installing battery cables and runs from the PV array are often difficult to avoid. Although conventional wire will often work just fine for the majority of applications, there are a few wire types that are of special interest for remote, cold-weather installations: “Arctic Flex” is a product that utilizes a special rubber insulating sheath that stays flexible up to very low temperatures. It is also a fine-stranded wire thus making it quite malleable and easy to work with. It is UL rated and National Electric Code (NEC) compliant. A wide range of sizes and colors are available. Welding cable, although not code compliant, offers a perfectly safe and considerably less expensive alternative for high-ampacity cabling requirements. For smaller wire sizes, automotive “primary” wire tends to be more flexible and easier to work with in the cold. Another favorite wire type of the polar installer is “SO” cord. This type of cord contains three or four insulated conductors inside an outer sheath. This is essentially the same material that extension cords are made out of. It is available in bulk in sizes up to #6 gauge. The outer sheathing varies widely in how flexible it remains in cold environments and seems to be somewhat color coded, with yellow and blue remaining the most flexible. Be sure to check the ratings. Armored “liquidtight” cable is heavier and more difficult to work with but offers a higher level of protection for the internal conductors. This is the type of cable to use for long runs in rocky or abrasive terrain or where animals might be a problem.

-

-

Remember that if wires are to be left exposed to the environment, they must be rated for exposure including UV radiation. The same energy that is providing power to your experiment can really take a toll on certain types of insulation. UV-resistant sheathing is generally marked as such on the outside. If it does not say “UV rated,” it probably is not. Remember to include the correct adapters to bring the cables and conduit into the junction boxes and enclosures. Every type of conduit, armored cable, or SO cord requires something a bit different. The devil is in the details, so make sure you have the correct adapters—and plenty of them. Again, pre-assembly at your home institution is an effective way to ensure you have what you need when you arrive at the field site. Combiner blocks, mechanical lugs, split bolts, and a variety of solderless connectors should have a place in your field tool kit. Rubber splicing tape and low-temperature electrical tape are essential as well. Red electrical tape serves as code tape to ensure that you know which of those black cables is the DC positive. The convention for DC color-coding is as follows: Red is for positive—the current-carying conductor. White is for negative. (I code tape mine black.) Green or bare is the equipment ground. The fine-stranded wire recommended above is much easier to work with in cold environments but poses some additional requirements for system installation and maintenance. Mechanical lugs can damage or break the fine strands resulting in a weak connection and reduced ampacity. Take care during installation, and regularly check the tightness on all connections during all maintenance visits.

Photovoltaic Power Systems Technology White Paper

17

The positive and negative conductors in a DC system should be kept close together and in parallel for any long runs to avoid inductive potential.

Grounding
Grounding is a deceptively complicated issue. Although the NEC requires equipment grounding on all PV systems regardless of operating voltage, obtaining a true earth ground in polar environments can often be difficult or impossible to obtain. In areas of permafrost, rocky soil, or muskeg, grounding plates or grounding rings made of 4/0 bare copper will typically provide a satisfactory earth ground. This earth ground must be bonded to every metal electrical box or component enclosure, receptacle, and bare metal frame. The PV panels should be interconnected at the point specified on the frame and referenced back to the earth ground. The grounding wire is never fused or switched, and the entire system must be grounded at only one point. In an ice cap environment, achieving an earth ground is typically not possible. As such, grounding is dealt with in the same way as within the automotive industry. In this method, the frame or chassis becomes the grounding point to which all of the negative conductors are referenced. Although not as good a system as a true earth ground, it does ensure that overcurrent devices will operate as designed. For an extensive discussion of system grounding, see the Sandia National Laboratories report, Photovoltaic Power Systems and the National Electric Code: Suggested Practices (2001). The PDF version is available at: http:// www.re.sandia.gov/en/ti/tu/Copy%20of%20NEC2000.pdf

Photovoltaic Power Systems Technology White Paper

18

Photovoltaic Power Systems Technology White Paper

19

Overcurrent Protection
Although remote scientific research projects are unlikely to receive a visit from the Electrical Inspector, it is wise to include adequate circuit protection. Breakers and fuses serve to protect the equipment, provide safety, and allow for easier maintenance of the system. Moreover, these devices protect conductors from currents exceeding the rated ampacity. The NEC specifies the maximum overcurrent protection for each conductor size. When the current exceeds the rated amperage of a breaker or fuse, the circuit opens and the flow of current ceases. Breakers are typically considered preferable, as they can simply be reset, whereas a blown fuse must be replaced. This necessitates having spare fuses on site. It should be noted that not all breakers are rated to handle DC. The arcing inherent in DC-type power systems will quickly burn out the contact points of a non-DC-rated breaker or switch. Specialized DC-rated breakers are available from most suppliers of PV equipment and should be used for main battery disconnects and other high-amperage applications. For smaller DC load protection, Square D “QO” series breakers are rated for up to 48 VDC and are widely available at a significantly lower cost. Breakers are triggered by unequal expansion of a bi-metal strip as current flows through it and heats it up. In cold climates, the rated ampacity of a breaker can end up significantly lower than the current level at which it actually trips. Fuses are somewhat less affected by temperature extremes. Remember that overcurrent protection is really providing protection for the conductors or wiring in a circuit rather than the electrical device itself. If multiple sizes of wiring exist within a protected circuit, the breaker or fuse must be sized to protect the smallest wire. Although your project may fall outside the auspices of the NEC, there is still good reason to comply with the provisions it contains to ensure a safe and reliable system. The NEC requires every ungrounded conductor to be protected by an overcurrent device. This is the positive wire in a DC system and the black and red conductors in an AC system. At a minimum, DC-rated overcurrent protection should be supplied: - Between the PV array and the charge controller, - Between the charge controller and the battery bank, - Between the battery bank and the DC load center, - Between the battery bank and the inverter (if present), and - For each DC circuit originating in the DC load center. At a minimum, AC overcurrent protection should be supplied: - For each AC circuit originating from the AC load center.

Power Consumption (Load)
In a well-designed PV system, there should be a relative balance of power. In other words, there should be enough power input to equal (and slightly exceed) the amount of power going out to instrumentation and other loads. In some instances, this will need to be calculated on an annual, rather than a daily or weekly, basis. A PV array or battery bank will ultimately lead to failure if it is too small, whereas the penalty for too large a system is excessive cost, weight, and difficulty of deployment. Essentially, a researcher should always plan on oversizing the system to ensure reliability. How much the system is oversized and where the emphasis will lie (PV vs. battery) are determined by the relative “safety margin” required and the amount of information available on solar insolation for the site. A 25% margin is usually considered normal, although a site with well-documented solar insolation and familiar system components might require only a 15% margin. For a relatively undocumented location and/or equipment, one might choose to run a 35% margin. For the purposes of this paper, the average value of 25% will be used. A couple of simple formulas help to define the relationship between the variables in the power balance: Power consumption = (instrument loads x time) + (system losses x time) Power available = (power input x time) – (system losses x time)

Photovoltaic Power Systems Technology White Paper

20

Power consumption can best be expressed in watt hours per day. A watt is the product of amps times volts: A x V = W. (Amps or current can also be expressed as I.) Watt hours is the product of watts multiplied by hours: W x time = watt hours. For a more in-depth discussion on electrical concepts, visit http://www.polarpower.org and navigate to Technologies > Power System Fundamentals. The best way to determine the average watt hours per day that your system requires is to first determine the cumulative amount of power used in a week, then divide by seven. As expressed above, the sum of all instrumentation and other loads should be padded by 25% to compensate for system losses.

Efficiency
Clearly, the greater the operating efficiency of a system, the lower the overall power requirements will be. In designing residential PV power systems, it is generally accepted that every $1 spent on energy efficiency measures results in $3 that will not have to be spent on additional power-producing equipment (i.e., a larger PV array, battery bank, etc.). Equivalent documentation does not seem to exist for this relationship in PV-powered research projects, but it is probably safe to assume that the ratio is equal to or greater than that expressed above. Small systems are relatively easy and inexpensive to deploy, whereas large systems are costly to build and often expensive and challenging to deploy. Note: It is in the researcher’s best interest to create systems that approach the problem comprehensively and that emphasize efficiency as one of the prime design criteria. Too often, instrumentation is selected on other criteria such as familiarity, but running an experiment in a laboratory setting and having it run reliably in a polar environment are two dramatically different things. Oftentimes, there is comparable equipment available that can perform the same function at a fraction of the power requirement. Time used in reducing the power requirement is invariably time well spent. Here are a few things to consider: 1. DC-Only Systems Most electronic equipment actually operates on DC power, despite the fact that most of the commercially available equipment is designed to plug in to AC power sources. This is because our electrical infrastructure, or grid, is an AC system due to its better transmission qualities. In essence, AC travels long distances better than DC. In a typical research project, however, distances are typically rather small, and DC may provide a more efficient power supply. Another advantage to a DC-only type of system is that it eliminates the inverter (DC to AC converter), which is one of the more costly and complicated items in a stand-alone power system. Although they are typically very reliable, inverters have certainly been known to fail. Keep it simple. The fewer components there are, the fewer places there are for a failure to occur. Consider that PV panels and the battery bank they supply are DC sources. It is best to try to match the system voltages across the board (e.g., 12-volt PV panels feed a 12-volt battery bank, which feeds 12-volt equipment), but this might not always be practical. It is generally easier to convert voltages downward (e.g., 24 volts to 12 volts), although step-up DC/DC converters are also available. Step-down DC/DC converters are very efficient and reliable. Design the system so that the primary system voltage matches or exceeds the highest voltage requirement in the system. System voltages should typically not exceed 48 VDC nominal. Higher DC voltages are suitable for some larger systems but require special equipment and present a much greater shock hazard. The actual DC requirement for a device typically intended for AC service is often listed on the nameplate information. It is often not very difficult to cut a device over to DC operation for dramatically enhanced efficiency. Essentially, the AC circuitry (rectifier and transformer) is

-

-

-

Photovoltaic Power Systems Technology White Paper

21

bypassed or removed. A DC/DC converter may be required to match the component requirement, but this is still typically much more efficient. Note: Familiarity with electronic equipment is a necessity! 2. Logic Circuits The use of a programmable logic circuit, or PLC, allows for much greater control of the system. For instance, does every instrument need to be on all the time for sampling, or could some be quiescent for the majority of the time, waking up to take a sample once an hour? The power reduction can be dramatic when this approach is taken. Many pieces of equipment have this functionality built right in. Ladder-logic circuitry can often be employed to control when instrumentation is active. As the name implies, ladder logic simply requires one step to be completed (parameter satisfied) before the next step is initiated. This can often be accomplished with relatively simple circuitry.

-

3. Thermal Strategies All electrical equipment performs best within a certain temperature regime, and typically this is not –40º C. (PV panels are the exception: The colder it gets, the more efficiently they work.) Efforts made to control the internal temperature environment can yield great rewards. Batteries have less available power, lower voltages, and accept a charge with greater difficulty at low temperatures. On the positive side, the self-discharge rates are much lower as temperatures decrease. Excessive heat will rapidly deteriorate the performance of a battery bank.

Most electrical components have temperature specifications as well. If they are operated outside of those parameters, reliability and accuracy cannot be assured. Obviously, a system that can maintain a more steadystate temperature—or at least reduce the dramatic swings—will perform better than a system with no thermal strategy employed. Except for medium to large systems of greater complexity, it is typically an acceptable strategy to moderate temperature extremes rather than attempt to hold a system within tight temperature parameters. To this end, batteries and other equipment should be housed inside enclosures. These enclosures should be well insulated. The inefficiencies discussed elsewhere in this section refer to energy that was not directly utilized to perform a function. The wasted energy is expressed as heat. In most polar environments, heat is a resource we can use. It should be the objective of every system designer to find ways to harness that otherwise wasted heat to modify the environment of the battery and/or equipment enclosure. Controlling the thermal environment of any type of enclosure, be it a battery box or a home, really relies on just three things: 1. A thermal energy source 2. Insulation to prevent the heat from escaping 3. Thermal mass to moderate temperature swings Methods employed vary widely from simple, passive systems to active systems that control temperature within tight parameters. How this problem is approached will be determined by how closely the temperature needs to be controlled and by the extremes of the environment the experiment is placed in. The simplest systems rely on waste heat as the thermal energy source, insulation, and the thermal mass of the batteries to moderate the swings. The next step up might incorporate water as an additional thermal mass by actively heating it whenever there is available PV energy in excess of system requirements. Hybrid systems utilizing engine generators can tap into an enormous amount of heat energy that would otherwise be wasted to the

Photovoltaic Power Systems Technology White Paper

22

environment. Finally, active systems can use stored energy (typically a fossil fuel source) to create on-demand heat as required. For more information on thermal strategies, see the general section on “Thermal Strategies” (http://polarpower.org under Technologies > Systems Integration).
Image courtesy of Solar Energy International.

Putting It All Together
Safety
Working in remote, polar environments poses some inherent difficulties. Long hours in extreme cold, wind, and blowing snow can make an already difficult job nearly impossible. It is tempting in these conditions to relax one’s standards and take shortcuts to get the job done more quickly. However, this is exactly the time when one should slow down and move more cautiously. Good work habits are safe work habits thereby reducing the risk of accident and injury and increasing the likelihood of successfully completing a project. In addition to the environmental hazards, installing PV systems bears its own potential hazards. The possibility of electrical shock, though low, does exist. Handling panels in high-wind situations is difficult and potentially dangerous and should be avoided. Batteries are typically the most dangerous components in a PV system. Although the shock hazard in a low-voltage system (< 50 volts) is relatively minor, batteries do have a very high short-circuit potential. Arcs can cause collateral damage by making a person jump back in reaction. In severe short-circuit instances, batteries have been known to explode. The acid electrolyte can cause severe burns, and the installer must be prepared to treat immediately with baking soda and water. Charging batteries can release hydrogen gas, which is highly flammable. A well-planned and organized work site will dramatically reduce the risks involved with PV installation. Pre-wiring as much as possible and performing a “dry run” while still at the home institution will ensure that everything works properly and will increase familiarity with the system. All of this helps to ensure a safe and successful field deployment. For more on safety, visit http://www.polarpower.org and navigate to Technologies > Power System Fundamentals.

Photovoltaic Power Systems Technology White Paper

23

System Voltage
One of the advantages of PV systems is that they are modular in nature and can be configured for 12, 24, 48, or even 120 DC volts or higher. For most smaller, autonomous systems, a 12- or 24-volt configuration will be optimal. These lower voltages pose a somewhat lesser electrical hazard and are closer to the operating voltages of equipment typically deployed for purposes of scientific research. Although 12-volt systems have fallen somewhat out of favor in the industry due to the larger gauge cabling required, for many science experiments, this is still the optimal voltage to utilize. When power requirements or longer distances require it, a 24-volt system will usually provide an adequate solution. For only very large systems with high power requirements or systems that need to run DC power for a substantial distance should one ever consider going above 48 volts. High-voltage DC poses significant safety hazards, and even most DC-rated devices are not rated for voltages above 50 VDC. PV panels are typically available in 12- or 24-volt nominal ratings. Panels can then be wired either in series, which increases voltage while the amperage remains the same, or in parallel, which increases amperage while the voltage remains the same. For example, two 12-volt/20-watt PV panels wired in series would yield 24 volts at a 1.67-amp output, or 40.08 watts. The same two panels wired in parallel would produce a 12-volt output with a 3.34-amp capability, which is still 40.08 watts. Series-parallel configurations are often used for larger arrays and result in increases in both volts and amps. These are typically configured in strings, with each string running to a combiner box. At the combiner box, the smaller leads from each string are bonded to larger conductors to carry the full current to the charge controller(s). Batteries are also modular and are typically available in 2-, 6-, or 12-volt ratings. The 2-volt cells are typically industrial-type batteries and are often already wired in series within an outer container. The 6- and 12-volt batteries are also composed of 2-volt cells, but they are molded into an integral unit. Most researchers will likely utilize 6- or 12-volt batteries. However, for higher power applications or instances where a very large battery bank is required to provide winter power for even low-power experiments, the 2-volt industrial cells can offer some significant advantages. Battery cabling can be expensive and time consuming, and often the footprint of a battery bank can end up being fairly large. Industrial cells are usually pre-configured in an outer container or a rack and utilize solid bars to interconnect a 12-volt string. Although the cells are typically rather heavy and must be handled individually, the finished bank can end up being much more compact and requires far fewer cable interconnections. As with PV panels, series-parallel connections are also possible. Note: It is very important to deliver and pull power from diagonal corners of the bank, thus ensuring equal loading of the system.

Photovoltaic Power Systems Technology White Paper

24

Image courtesy of Solar Energy International.

Photovoltaic Power Systems Technology White Paper

25

Image courtesy of Solar Energy International.

Photovoltaic Power Systems Technology White Paper

26

Image courtesy of Solar Energy International.

Photovoltaic Power Systems Technology White Paper

27

Photovoltaic Power Systems Technology White Paper

28

Image courtesy of Solar Energy International.

System Monitoring
At a minimum, every PV system should display the current status in terms of voltage and current flow. This allows the researcher to tell at a glance how the system is performing and what the energy balance looks like. Voltage alone does not tell the whole story and is not an adequate measure of system status. There are now several monitoring devices available that provide a wealth of information on how the system is performing, not only at the present moment but also over time. A cumulative amp hour reading is a very useful tool, as is the battery bank percent-full reading. One excellent, low-power battery monitor is the “Trimetric” (see: http:// www.bogartengineering.com/ ). Any meter of this type will require installation of a shunt to measure energy flowing into and out of the battery bank. Bear in mind that this device utilizes a digital display and microswitches that may not perform well at extremely low temperatures. Some thermal regulation of the environment is advised. Autonomous systems with remote monitoring access are becoming increasingly popular as polar researchers continue to push the limits of where and when scientific investigations can be accomplished. The advantages of near real-time system monitoring are fairly obvious to anyone who has deployed systems in the field. Without remote monitoring, it is impossible to know if the system is functioning properly. Many researchers have returned to a field site after a year to find that their instrument stopped working shortly after deployment. In some instances, the opportunity to collect that data set might never again be available. Advances in the communications industry have made remote monitoring a realistic possibility in many cases. Lower prices, reduced power requirements, smaller dishes, and the nearly global nature of satellite coverage have made this technology more widely available to the research community. There is a penalty involved in terms of system complexity and increased power requirements, but in many instances, it is well worth the cost. When this functionality is introduced into a system, near real-time scientific data transfer becomes possible as well. Please visit http://polarpower.org under Technologies > Systems Integration for a more detailed discussion on Communications. Also visit > Examples > By Location > Alaska for a look at the Ivotuk autonomous system with full monitoring and data transfer capabilities. Link to the site live at: http://transport.sri.com/ivotuk/.

Fundamental Design Principles
Before moving on to the worksheet, one more area of basic system design should be covered. That is, how does it all physically fit together as a system? Stated simply, there are three basic approaches: 1. Single unit: All of the components are housed in a single enclosure with the PV, the batteries, the balanceof-system components, and perhaps even the science equipment integrated into the design. 2. Modular: Components are set up as modules that can be linked together and added onto as system requirements dictate. 3. Hybrid: This is essentially a combination of the first two concepts. There is a single main unit that contains the battery bank, the controls, and so forth but with separate PV array(s) as well as other possible power sources. Each of these approaches is valid with intrinsic positive and negative features that will determine the suitability for a given project. The single-unit approach can be quite attractive and offers the benefit of being able to keep everything together with minimum field set-up required. However, how will it be deployed? Typically, this arrangement requires the use of equipment, be it ground based, helicopter, or fixed wing. Unless it is a very small system, this ends up being a rather large and difficult box to move. If the researcher has access to the required equipment, the advantages are hard to beat. This is also the easiest method for utilizing engine generators for on-demand power and offers the option of heat-recovery thermal strategies. The modular approach is attractive for smaller projects or for areas where deployment will be an issue. There are numerous possible permutations of the basic design. As an example, consider a central unit containing the battery

Photovoltaic Power Systems Technology White Paper

29

bank, the integral PV array, and the balance-of-system components including a place for science equipment. Additional PV arrays, wind turbines, battery banks, and so forth can be added on as power requirements dictate. The advantages here are: Ease of deployment: All of the components can be handled manually without the use of heavy equipment. The individual modules can be transported to the site via small aircraft and moved into position by hand. There are limitations, however. Easy expansion of the system: It seems almost inevitable that project scopes grow. As additional instrumentation loads are added on, the power requirements go up. Being able to plug in another PV array or battery bank without extensive system modification is a great advantage.

-

Disadvantages include: More difficult to create effective thermal strategies. No room for personnel to get out of the weather to work on equipment. Essentially, plan on working on everything outside, be it fair weather or foul. Setting up a tent adjacent to or even over the top of the system somewhat obviates this drawback.

The hybrid solution offers the option to draw on the best characteristics of both of the previous strategies. This can, however, prove to be a rather costly approach and may not be suitable for all projects. For examples of different types of PV Systems, visit http://polarpower.org and navigate to Examples > By Type of System > Solar.

This document was compiled by Tracy Dahl. Tracy can be contacted at Polarsolar@direcway.com.

Photovoltaic Power Systems Technology White Paper

30

Footnoted References 1. Rauschenbach, H. S. (1980). Solar Cell Array Design Handbook. New York: Van Norstrand Reinhold. 2. Ross, M., Royer, J. (1999). Photovoltaics in Cold Climates. London: James & James. Chapter 3, The Solar Resource in Cold Climates.” Perers, Bengt. 3. Ross, M., Royer, J. (1999). Photovoltaics in Cold Climates. London: James & James. Chapter 6, “Battery Issues.” Spiers, David. 4. McChesney, P. J. (2000). Solar Electric Power for Instruments at Remote Sites (Open File Report 00-128). Reston, VA: U.S. Geological Survey. General References: 1. Solar Energy International. (2004). Photovoltaics Design and Installation Manual. Gabriola Island, BC: New Society Publishers. 2. Wiles, J. (2001). Photovoltaic Power Systems and the National Electric Code: Suggested Practices. Albuquerque, NM: Sandia National Laboratories. 3. Awaya, H., et al. (1999). Autonomous Systems in Extreme Environments (white paper resulting from workshop). Pasadena, CA: Jet Propulsion Laboratory. 4. International Energy Agency (IEA). (1999). Stand Alone Photovoltaic Applications: Lessons Learned. London: James & James. Internet References: 1. National Renewable Energy Laboratory: http://www.nrel.gov/ 2. Sandia National Laboratories: http://www.sandia.gov/ 3. Northern Arizona Wind & Sun: http://www.windsun.com/ 4. Concorde Battery Corporation: http://www.concordebattery.com/ 5. Alternative Energy Engineering: http://www.aeesolar.com/ 6. Polar Power Incorporated: http://www.polarpowerinc.com/ 7. Solar Energy International: http://www.solarenergy.org/ A special thank you to Johnny Weiss at Solar Energy International for providing many of the graphics found in this document.

Photovoltaic Power Systems Technology White Paper

31

Photovoltaic System Sizing Worksheet I. Load Analysis DC Loads Equipment _________ _________ _________ _________ AC Loads Equipment _________ _________ _________ _________ 1. 2. 3. 4. 5.

Qty x volts x amps = watts x hr/day = watt hr/day x 7 = watt hr/week __________________ x __________________ x _________ = __________________ x __________________ x _________ = __________________ x __________________ x _________ = __________________ x __________________ x _________ =

_________ _________ _________ _________

Qty x V x A x 1.2 = watts x hr/day = watt hr/day x 7 = watt hr/week __________________ x __________________ x _________ __________________ x __________________ x _________ __________________ x __________________ x _________ __________________ x __________________ x _________

= = = =

_________ _________ _________ _________

Total power requirement in watt hours per week. Multiply total by 1.2 to compensate for system losses during the battery charge/discharge cycle. Enter the nominal voltage of the battery bank. Divide line 2 by line 3. This is the amp/hr requirement per week. Divide line 4 by 7 days. This is the average amp/hr requirement per day that will be used to size the battery bank and PV array.

_______ _______ _______ _______ _______

II. Optimize Power System Demands Examine power consumption and reduce total power requirements as much as possible. Identify any large and/or variable loads and try to eliminate them or find alternatives. Consider the preferential use of DC devices over AC to reduce losses in the conversion process. If there are large loads that cannot be eliminated, consider periodic sampling, use only during peak sun hours, or use only during the summer. Revise the load sizing worksheet with the now optimized results. III. Size the Battery Bank 6. 7. 8. Enter the maximum number of days of autonomy the system must support. Multiply line 5 by line 6. This is the amount of amp/hrs the system must store. Enter the depth of discharge for the battery chosen. The value should not exceed 0.5 (50% depth of discharge). This prevents overdischarge and potential freezing of the electrolyte. Divide line 7 by line 8. Select the multiplier below that corresponds to the average winter temperature the battery bank will experience. _______ _______ _______ ºC 10 4.4 -1.1 -6.7 -10 -15 -20 -25 -30 -35 -40 -50 ºF 50 40 30 20 14 5 -4 -13 -22 -31 -40 -58 Multiplier 1.19 1.30 1.40 1.59 1.65 1.80 1.95 2.10 2.50 2.75 3.33
Forget it! Use a thermal strategy to keep batteries warmer.

9. 10.

_______ _______

*Note: The multipliers from –10º C/14º F and below are approximate. Information on battery performance in extreme cold is practically non-existent. This chart illustrates the importance of thermal regulation of the battery compartment.

Photovoltaic Power Systems Technology White Paper

32

11.

12. 13. 14. 15.

Multiply line 9 by line 10. This ensures that the battery bank will have enough capacity to overcome cold weather effects and represents the total battery capacity needed. Enter the amp hour rating for the battery chosen. Divide line 11 by line 12 and round off to the next higher number. This is the number of batteries wired in parallel required. Divide the nominal system voltage by line 3 and round off to the next higher number. This is the number of batteries wired in series required. Multiply line 13 by line 14. This is the total number of batteries required.

_______

_______ _______ _______ _______

IV. Determining the Solar Resource Several factor influence how much solar insolation exposure the PV modules will experience. Latitude is the overriding factor in the Polar Regions and can be determined with some precision. Local weather conditions, the location and angle of the PV array, fixed mounting versus tracking, and whether the system will be running in the summer, winter, or year-round must all be taken into consideration. Determine an hour-per-day average for the desired site. V. Size of the PV Array 16. 17. 18. 19. 20. 21. Average sun hours per day. Divide line 5 by line 16. This is the total array amps required. Optimum or peak amps of solar module used. Multiply line 18 by 0.8 for normal loads or by 0.7 for critical loads. Divide line 17 by line 19 and round off to the next highest number. This is the number of solar modules in parallel required. Multiply line 20 by the number of modules required to achieve the nominal DC voltage of the battery bank. This is the total number of PV modules required. _______ _______ _______ _______

_______

VI. Charge Controller 22. Multiply line 17 by 1.25. This is the minimum amp rating of the controller. The voltage rating of the charge controller must match the system DC voltage. _______

* Worksheet adapted from Autonomous Systems in Extreme Environments, a white paper resulting from the 1999 event hosted by JPL.

Photovoltaic Power Systems Technology White Paper

33

Similar Documents

Free Essay

Assignment Layouts

...Sample Formats LS Business Publishing LS Education Group Sample Formats & Guidelines Contents 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 Format of a Report ............................................................................................................................ 2 Format of a Briefing paper ................................................................................................................ 3 Format of Newsletter ........................................................................................................................ 4 Format of Leaflet............................................................................................................................... 6 Format of Presentation ..................................................................................................................... 7 Format of a Questionnaire ................................................................................................................ 8 Format of a Discussion paper ........................................................................................................... 9 Format a White paper ..................................................................................................................... 10 Format of Articles............................................................................................................................ 11 1.0 Format of a Report 1.0 Executive Summary This needs to be at...

Words: 1455 - Pages: 6

Free Essay

Art of Whitepaper

...The Art of the White Paper July 2003 Executive Summary...................................................................1 What is a White Paper? .............................................................2 White Papers Come in Many Flavors..........................................3 Why Write a White Paper? ........................................................3 Industry Standards for White Papers ........................................4 Who Reads White Papers?.........................................................5 Who Writes White Papers? ........................................................6 Success Factors for White Papers..............................................7 A Gordon & Gordon Success Story.............................................8 Copies of this white paper can be obtained from www.gordonandgordon.com/downloads.html © 2001-2003 by Manuel Gordon and Gordon Graham Executive Summary High-tech companies produce a lot of white papers, and many IT managers use them—even if no one can clearly explain what they are. This paper begins by describing the various kinds of white papers, and the various purposes for which they are needed. Although no industry standards exist for white papers, we can make some generalizations. Most white papers are around 10 letter-sized pages with black & white illustrations. They are written with an authoritative, neutral tone. Most are distributed through the Web as PDFs. They can take from 4 to 10 weeks and cost from...

Words: 2701 - Pages: 11

Premium Essay

Academic Exclence

...There is nothing more important to the Government than raising the standards children achieve in our schools. The White Paper Excellence in schools committed us to exacting targets, and proposed a challenging programme to achieve them. Our vision is of excellence for all. This inclusive vision encompasses children with special educational needs (SEN). Schools currently identify 18% of children as having special educational needs of differing kinds. Almost 3% have individual statements showing the additional special educational provision they require. This Green Paper asks some questions about these figures. What is not in question is the case for setting our sights high for all these children. Good provision for SEN does not mean a sympathetic acceptance of low achievement. It means a tough-minded determination to show that children with SEN are capable of excellence. Where schools respond in this way, teachers sharpen their ability to set high standards for all pupils. The great majority of children with SEN will, as adults, contribute economically; all will contribute as members of society. Schools have to prepare all children for these roles. That is a strong reason for educating children with SEN, as far as possible, with their peers. Where all children are included as equal partners in the school community, the benefits are felt by all. That is why we are committed to comprehensive and enforceable civil rights for disabled people. Our aspirations as a...

Words: 257 - Pages: 2

Free Essay

Content

...ioninteractive.com MARKETING Idea Book for Turning Content into Conversions C NTENT CREATE ENGAGE MARKET STRATEGIZE Landing Pages for Content is clearly king. That passion to learn is the fuel of content marketing. Valuable content spreads like wildfire—providing opportunities for the brands behind the content to capitalize on their blogs, white papers, infographics, webinars and slide decks. This guide to Landing Pages for Content Marketing takes a practical look at exactly how to deliver measurable, significant conversions for each of the major categories of content. Beyond the narrow view of dumping your content, behind a lead capture form (often called “gating the assets”), there exists creative ways to up-sell and cross-sell content to convert your audience’s attention into business results. This approach preserves the social and organic viability of content, while improving its business value. It also adds a new ROI layer of measurement and comparison to content marketing initiatives. For each category of content, we give you a couple of tactics —letting you get your feet wet with one before jumping into another. Everything here is designed to deepen engagement and participation with your brand while providing you with © i-on interactive, inc. All rights reserved. Across markets and personas, people have an insatiable appetite to consume information. measurable results from your content marketing initiatives—driving qualified leads & sales for your organization...

Words: 2467 - Pages: 10

Free Essay

The Air Force and Army Strategic Plans for Modernization

...modernizing the United States’ military. The strategic plans that each branch outlined in their respective White Papers both emphasize the need for new technologies and continual modernization. Both branches recognize that changes need to be made, but the Air Force and Army differ in the scope and execution of these changes within their branches. Although these details vary, both plans have the common goal of modernizing our military to stay one step ahead of our adversaries and maintaining our global military dominance. Both White Papers echo the age old adage that “compliancy breeds failure”. The Army and the Air Force are both using lessons learned to try to predict future technological needs in an increasingly unpredictable global environment. Details and means differ, but both branches agree that the best way to have a dominant presence while dealing with financial constraints is to focus on unmanned technologies and specialized equipment. The Army is focusing on unmanned aerial vehicles, small unmanned ground vehicles, and modernized surveillance systems (2009 ARMY MODERNIZATION WHITE PAPER). The Air Force, similarly, is building self-sustaining computer networks so that human resources can be focused elsewhere. Also, the strategic plans both emphasis the need of specialized equipment for Special Forces (Moseley, 2007). The strategic plans outlined in the two White Papers agree that our modernized military must focus on specialized equipment for strategic use and an unmanned...

Words: 528 - Pages: 3

Premium Essay

Ifsm 370 Project 2: White Paper Instructions

...IFSM 370 Project 2: White Paper Instructions Follow Below Link to Download Tutorial https://homeworklance.com/downloads/ifsm-370-project-2-white-paper-instructions/ For More Information Visit Our Website ( https://homeworklance.com/ ) Email us At: Support@homeworklance.com or lancehomework@gmail.com Introduction This is an individual project. Each student must complete a White Paper that proposes a telecommunications solution to address a communications problem for a business organization. The target audience will be the organization’s Chief Information Officer (CIO). The White Paper deliverable is an MS Word document. If you have never written a white paper, you should conduct some research and review sample white papers to understand the content and format associated with these professional documents. The completed White Paper deliverable is due by 11:59 PM Eastern Time on the due date shown in the Course Schedule. See the Additional Information section of the syllabus for the penalty for late or missed assignments and projects. The White Paper is valued at 12% of the course grade. Scenario Ullman, Manly, & Ulysses Corporation With 75,000 customers worldwide, 250 employees working in four locations in the United States and three European offices, and a catalog of more than 100,000 parts, Ullman, Manly & Ulysses Corporation (UMUC) relies on its network for its survival. In the past decade, UMUC has seen its business grow from just one location...

Words: 1357 - Pages: 6

Premium Essay

Proposal on Impact of Solar Panel

...Solar energy can be harnessed. So, solar panel technology is advised. A total of 3,00,000 solar panels had been installed in more than 40,000 villages of 456 upazilas of all districts of Bangladesh. Daily on average 44 MW electricity is being produced by these solar panels.( Momotaz and Karim,2012).Now a days solar panel is applied in different aspects such as solar based recharging station ,solar cooking etc. It presents an attractive alternative to conventional electricity such as no monthly bills, no fuel cost, little repair and maintenance costs, easy to install any where etc. The solar panel technology is very effective to illuminate rural households and power other essential home appliances, such as lights, radios and small black and white televisions. Again, the main advantages of solar panels are that it is absolutely pollution free, inexhaustible and especially suitable for deserts and isolated places where other sources are not available. It is less expensive and only utilizing the proper use...

Words: 3305 - Pages: 14

Premium Essay

Research, Solar Cell Production and Market Implementation of Photovoltaics

...eu Tel.: +39 0332 789119 Fax: +39 0332 789268 http://ie.jrc.ec.europa.eu www.jrc.ec.europa.eu PV Status Report 2011 Research, Solar Cell Production and Market Implementation of Photovoltaics July 2011 Arnulf Jäger-Waldau European Commission, DG Joint Research Centre, Institute for Energy, Renewable Energy Unit Via Enrico Fermi 2749; TP 450 I – 21027 Ispra (VA), Italia EUR 24807 EN Legal notice Neither the European Commission nor any person acting on behalf of the Commission is responsible for the use, which might be made of the following information. The report does not represent any official position of the European Commission, nor do its contents prejudge any future Commission proposals in any areas of Community policy. A great deal of additional information on the European Union is available on the Internet. It can be accessed through the Europa server http://europa.eu/ JRC 64900 EUR 24807 EN ISBN 978-92-79-20171-4 ISSN 1831-4155 doi 10.2788/87966 The report is online available at: http://re.jrc.ec.europa.eu/refsys/ Luxembourg: Office for Official Publications of the European Union © European Union, 2011 Reproduction is authorised provided the source is acknowledged Design: sailer design communication, Meersburg, Germany Printed in Belgium Printed on recycled paper. 4 | PV Status Report 2011 PV Status Report 2011 | 5 Preface...

Words: 62002 - Pages: 249

Premium Essay

Estimation of Solar Energy for Street Lights in Vit

...ESTIMATION OF SOLAR ENERGY FOR STREET LIGHTS IN VIT ABSTRACT A solar lighting system which can make a 18x3 w lamp glow continuously for about (7) hours if the battery is fully charged has been constructed. Here, solar energy is collected with the aid of a solar panel and thus, a battery is charged during day time with the help of a simple charging circuit. During night time, this stored energy is used to light. The device can be used for small-scale lighting applications in remote areas that are far away from the power grid. The system has a panel to collect the sun’s energy, a battery to store that energy and a light source to use the energy. The system operates like a bank account. Withdrawals from the battery to power the light source must be compensated for by commensurate deposits of energy form the solar panels. INTRODUCTION Electricity is becoming costly every day; so many people are getting interested in using solar energy to fulfil their electricity needs. Power cuts and dependency on Generators is making people look for better sources. Solar Photo Voltaic panels provide a very good alternative way to fulfil their demand. Ministry of New and Renewable Energy (MNRE), Government of India is also promoting solar PV systems under the Jawaharlal Nehru National Solar Mission (JNNSM) in our country. They also provide subsidise solar panels under this scheme. There are so many people, interested in buying solar panels in India so we thought of doing a research on price...

Words: 2929 - Pages: 12

Premium Essay

Renewable Energy

...Experience with Promotion of Renewable Energy: Successes and Lessons Learned Parliamentarian Forum on Energy Legislation and Sustainable Development Cape Town, South Africa 5-7 October, 2005 Richard L. Ottinger[?] Abstract: Renewable energy is becoming economic in all markets as its rapid growth results in more competitive prices. It is particularly appropriate and increasingly being adopted for providing electric power services to rural areas in developing countries unlikely to be served by grid electricity. Policies needed to implement renewable energy systems in rural areas are discussed in this paper. Most prominent are removal of subsidies to traditional energy primarily benefiting the wealthiest; involving the local populace in decision making; educating financial institutions about the economics of investing in renewable energy systems and creating investment vehicles appropriate to financing them in poor localities; training personnel on management, maintenance and drafting contracts; requiring vendor provision of maintenance and parts; and effective regulation and oversight of system management and financing. I. Introduction The recent sharp increases in the prices of oil, natural gas, uranium and coal underline the importance for all countries to focus on development of alternative energy resources. For developing countries, these price increases can have ruinous economic consequences; for many countries already plagued by poverty this means...

Words: 14169 - Pages: 57

Free Essay

Causes and Effects of Stroke

...meat used in frozen prepared meals. They are usually manufactured with a carcinogenic ingredient known as sodium nitrite. This is used as a color fixer by meat companies to turn packaged meats a bright red color so they look fresh. Unfortunately, sodium nitrite also results in the formation of cancer-causing nitrosamines in the human body. And this leads to a sharp increase in cancer risk for those who eat them. meat processing, preparation of meat for human consumption. Meat is the common term used to describe the edible portion of animal tissues and any processed or manufactured products prepared from these tissues. Meats are often classified by the type of animal from which they are taken. Red meat refers to the meat taken from mammals; white meat refers to the meat taken from fowl; seafood refers to the meat taken from fish and shellfish; and game refers to meat taken from animals that are not commonly domesticated. Meat that has been processed gets plenty of bad press linking it to cancer, heart disease and obesity. Y! Lifestyle investigates what meats fall into this category and why they’re so bad for you Process II How Advertising is conducted Many small and large organizations have invested and benefited greatly from pay per click services.  The ads that are personalized to the user’s interests use this model, and if required, can also provide them based on locality.  A PPC advertising company provides these services to businesses, but the special part...

Words: 2580 - Pages: 11

Free Essay

Solar Energy : the Present and Future of the Middle East

...Middle East. A region that is solely dependent on oil and gas as a form of energy. Since oil and gas is non-renewable and also damages the environment severely, countries in the Middle East have turned to a different form of energy. solar energy has become its direct competitor in recent years. The different projects and prospects that each country in the Middle East is pushing towards is a clear example of how important solar energy has become to these countries. Increase in economy and the many advantages of having solar energy for the environment are two benefits that this source of power is capable of providing to these countries. A limitation of solar panels is an aspect that helps gives both sides to this research paper. Accordingly this research paper discusses how all these factors are benefiting the Middle East and hence should solar energy be the main source of energy in this region. Solar Energy: The Future and Present of the Middle East Solar energy is the energy from the sun that is converted into thermal or electrical energy. It is one of the most abundant and cleanest renewable energy sources available, since it’s directly obtained from the sun. Solar energy has been around since the time of Neanderthals on this earth; in 700 BC humans first used the sunlight to make fire with magnifying glasses (Maehlum, 2013, para. 3). This shows that solar energy and its implementation have been around for a long time, but only recently did people just learn how to harness...

Words: 3439 - Pages: 14

Premium Essay

Global Warming

...GLOBAL WARMING Introduction Global warming begins when sunlight reaches Earth. The clouds, atmospheric particles, reflective ground surfaces and ocean surface then reflected about 30 percent of it back into space, while the remaining is absorbed by oceans, lands and air. This in turn heats the planet’s surface and atmosphere, making life possible. As Earth warmed up, this solar energy is radiated by thermal radiation or infrared heat, traveling directly out to space, thus cooling the Earth. However, some of the outgoing radiation is re-absorbed by carbon dioxide, water vapor and other gases in the atmosphere and is radiated back to Earth’s surface; these gases are known as greenhouse gases due to their heat-trapping capacity. This re-absorption process is naturally good; the Earth’s average surface temperature would be very cold if not for the greenhouse gases. The problem begins when the concentration of greenhouse gases in the atmosphere were artificially raised by humankind at an ever-increasing rate since the past 250 years. As of 2004, over 8 billion tons of carbon dioxide was pumped out per year; natural carbon sinks such as forests and the ocean absorbed some of this, while the rest accumulated in the atmosphere. Millions of pounds of methane are produced in landfills and agricultural decomposition of biomass and animal manure. Nitrous oxide is released into the atmosphere by nitrogen-based fertilizers and other soil management practices. Once released, these greenhouse...

Words: 12237 - Pages: 49

Premium Essay

Renewable Energy

...future with renewable energy Only a very small percentage of the energy from the sun reaches the earth. However, one hour of that sunshine provides enough energy to power the entire world for a year (National Geographic, n.d.). As America moves forward into the 21st century, U.S. environmental policies need to do more to encourage green renewable energy technology thus reducing dependence on foreign oil, while focusing on environmental concerns, and helping to ensure that the United States remains a world leader. Methods Initial research for this project began with a look at U.S. government statistics and websites. However, as the research continued the Ashford library became a valuable source of information. This research paper is a combination of scholarly journal articles and other reliable articles from reputable news organizations. Some of the data came from teams of scientists and other international organizations that collect and organize data about renewable energy and environmental issues. One source that was particularly useful was America’s Energy Future (2009); the book was written by the Committee on America’s Energy future, the National Academy of Sciences, the National Academy of Engineering, and the National Research Council. Even though the information contained in this research project came from reliable sources, the information reported has been cross-referenced with other credible sources for accuracy. Government issues The enormous...

Words: 2161 - Pages: 9

Free Essay

Trends in the Market for Silver

...was used as a currency. Used as both an industrial metal and a hard asset, it plays double duty in the commodities market. It has also become an investment vehicle which provides a safe haven from the unpredictable stocks and bonds. Trading it and predicting its price is a careful balancing act between what consumers need and what the currency market demands. The objective of the paper is to study the demand and supply mechanism for the silver market. Due to the dynamic nature of the market, the demand and supply forces keep changing due to various reasons; the author has tried to find the same. The author has further tried to study the implications of the demand and supply on the price trends. The research and analysis primarily gives a broad description of the current trends in the market for silver. The paper examines only the spot prices and the study does not include future market. The paper tries to examine how India is a part of the global market. After establishing a link between international and domestic silver market, the paper looks at the price trends beginning from 2005. The paper examines the reason for rise and fall of the prices and analyses the trends to predict how the prices can move in the...

Words: 4147 - Pages: 17