S H E L L- A N D - T U B E H E AT E X C H A N G E R S

Effectively Design Shell-and-Tube Heat Exchangers
To make the most of exchanger design software, one needs to understand STHE classification, exchanger components, tube layout, baffling, pressure drop, and mean temperature difference.
Rajiv Mukherjee, Engineers India Ltd.

T

hermal design of shell-and-tube heat exchangers (STHEs) is done by sophisticated computer software. However, a good understanding of the underlying principles of exchanger design is needed to use this software effectively. This article explains the basics of exchanger thermal design, covering such topics as: STHE components; classification of STHEs according to construction and according to service; data needed for thermal design; tubeside design; shellside design, including tube layout, baffling, and shellside pressure drop; and mean temperature difference. The basic equations for tubeside and shellside heat transfer and pressure drop are wellknown; here we focus on the application of these correlations for the optimum design of heat exchangers. A followup article on advanced topics in shell-and-tube heat exchanger design, such as allocation of shellside and tubeside fluids, use of multiple shells, overdesign, and fouling, is scheduled to appear in the next issue.

• baffles; and • nozzles. Other components include tie-rods and spacers, pass partition plates, impingement plate, longitudinal baffle, sealing strips, supports, and foundation. The Standards of the Tubular Exchanger Manufacturers Association (TEMA) (1) describe these various components in detail. An STHE is divided into three parts: the front head, the shell, and the rear head. Figure 1 illustrates the TEMA nomenclature for the various construction possibilities. Exchangers are described by the letter codes for the three sections — for example, a BFL exchanger has a bonnet cover, a two-pass shell with a longitudinal baffle, and a fixed-tubesheet rear head.

Components of STHEs It is essential for the designer to have a good working knowledge of the mechanical features of STHEs and how they influence thermal design. The principal components of an STHE are: • shell; • shell cover; • tubes; • channel; • channel cover; • tubesheet;
©Copyright

Classification based on construction Fixed tubesheet. A fixed-tubesheet heat exchanger (Figure 2) has straight tubes that are secured at both ends to tubesheets welded to the shell. The construction may have removable channel covers (e.g., AEL), bonnet-type channel covers (e.g., BEM), or integral tubesheets (e.g., NEN). The principal advantage of the fixedtubesheet construction is its low cost because of its simple construction. In fact, the fixed tubesheet is the least expensive construction type, as long as no expansion joint is required. Other advantages are that the tubes can be cleaned mechanically after removal of

CHEMICAL ENGINEERING PROGRESS • FEBRUARY 1998

1997 American Institute of Chemical Engineers. All rights reserved. Copying and downloading permitted with restrictions.

S H E L L- A N D - T U B E H E AT E X C H A N G E R S

Stationary Head Types

Shell Types

Rear Head Types

E A One-Pass Shell

L Fixed Tube Sheet Like "A" Stationary Head

Removable Channel and Cover F Two-Pass Shell with Longitudinal Baffle M Fixed Tube Sheet Like "B" Stationary Head

B N G Bonnet (Integral Cover) Split Flow Fixed Tube Sheet Like "C" Stationary Head

P H C Double Split Flow Integral With Tubesheet Removable Cover S Floating Head with Backing Device J Divided Flow T N Pull-Through Floating Head Channel Integral With Tubesheet and Removable Cover Outside Packed Floating Head

K U Kettle-Type Reboiler U-Tube Bundle

D X W Externally Sealed Floating Tubesheet

Special High-Pressure Closures

Cross Flow

s Figure 1. TEMA designations for shell-and-tube heat exchangers.
CHEMICAL ENGINEERING PROGRESS • FEBRUARY 1998

the channel cover or bonnet, and that leakage of the shellside fluid is minimized since there are no flanged joints. A disadvantage of this design is that since the bundle is fixed to the shell and cannot be removed, the outsides of the tubes cannot be cleaned mechanically. Thus, its application is limited to clean services on the shellside. However, if a satisfactory chemical cleaning program can be employed, fixed-tubesheet construction may be selected for fouling services on the shellside. In the event of a large differential temperature between the tubes and the shell, the tubesheets will be unable to absorb the differential stress, thereby making it necessary to incorporate an expansion joint. This takes away the advantage of low cost to a significant extent. U-tube. As the name implies, the tubes of a U-tube heat exchanger (Figure 3) are bent in the shape of a U. There is only one tubesheet in a Utube heat exchanger. However, the lower cost for the single tubesheet is offset by the additional costs incurred for the bending of the tubes and the somewhat larger shell diameter (due to the minimum U-bend radius), making the cost of a U-tube heat exchanger comparable to that of a fixedtubesheet exchanger. The advantage of a U-tube heat exchanger is that because one end is free, the bundle can expand or contract in response to stress differentials. In addition, the outsides of the tubes can be cleaned, as the tube bundle can be removed. The disadvantage of the U-tube construction is that the insides of the tubes cannot be cleaned effectively, since the U-bends would require flexible-end drill shafts for cleaning. Thus, U-tube heat exchangers should not be used for services with a dirty fluid inside tubes. Floating head. The floating-head heat exchanger is the most versatile type of STHE, and also the costliest. In this design, one tubesheet is fixed relative to the shell, and the other is

free to “float” within the shell. This permits free expansion of the tube bundle, as well as cleaning of both the insides and outsides of the tubes. Thus, floating-head SHTEs can be used for services where both the shellside and the tubeside fluids are dirty — making this the standard construction type used in dirty services, such as in petroleum refineries. There are various types of floating-head construction. The two most common are the pull-through with backing device (TEMA S) and pullthrough (TEMA T) designs. The TEMA S design (Figure 4) is the most common configuration in the chemical process industries (CPI). The floating-head cover is secured against the floating tubesheet by bolting it to an ingenious split backing ring. This floating-head closure is located beyond the end of the shell and contained by a shell cover of a larger diameter. To dismantle the heat exBonnet (Stationary Head)

changer, the shell cover is removed first, then the split backing ring, and then the floating-head cover, after which the tube bundle can be removed from the stationary end. In the TEMA T construction (Figure 5), the entire tube bundle, including the floating-head assembly, can be removed from the stationary end, since the shell diameter is larger than the floating-head flange. The floatinghead cover is bolted directly to the floating tubesheet so that a split backing ring is not required. The advantage of this construction is that the tube bundle may be removed from the shell without removing either the shell or the floatinghead cover, thus reducing maintenance time. This design is particularly suited to kettle reboilers having a dirty heating medium where U-tubes cannot be employed. Due to the enlarged shell, this construction has the highest cost of all exchanger types.
Bonnet (Stationary Head)

Stationary Tubesheet

Support Bracket

Stationary Tubesheet

Baffles

Tie Rods and Spacers

s Figure 2. Fixed-tubesheet heat exchanger.
Header Tubeplate Shell Tubes Baffles

s Figure 3. U-tube heat exchanger.
FEBRUARY 1998 • CHEMICAL ENGINEERING PROGRESS

S H E L L- A N D - T U B E H E AT E X C H A N G E R S

There are also two types of packed floating-head construction — outsidepacked stuffing-box (TEMA P) and outside-packed lantern ring (TEMA W) (see Figure 1). However, since they are prone to leakage, their use is limited to services with shellside fluids that are nonhazardous and nontoxic and that have moderate pressures and temperatures (40 kg/cm2 and 300°C).

Classification based on service Basically, a service may be singlephase (such as the cooling or heating of a liquid or gas) or two-phase (such as condensing or vaporizing). Since there are two sides to an STHE, this can lead to several combinations of services. Broadly, services can be classified as follows: • single-phase (both shellside and tubeside); • condensing (one side condensing and the other single-phase); • vaporizing (one side vaporizing and the other side single-phase); and • condensing/vaporizing (one side condensing and the other side vaporizing). The following nomenclature is usually used: Heat exchanger: both sides singlephase and process streams (that is, not a utility). Cooler: one stream a process fluid and the other cooling water or air. Heater: one stream a process fluid and the other a hot utility, such as steam or hot oil. Condenser: one stream a condensing vapor and the other cooling water or air. Chiller: one stream a process fluid being condensed at sub-atmospheric temperatures and the other a boiling refrigerant or process stream. Reboiler: one stream a bottoms stream from a distillation column and the other a hot utility (steam or hot oil) or a process stream. This article will focus specifically on single-phase applications.

Design data Before discussing actual thermal design, let us look at the data that must be furnished by the process licensor before design can begin: 1. flow rates of both streams. 2. inlet and outlet temperatures of both streams. 3. operating pressure of both streams. This is required for gases, especially if the gas density is not furnished; it is not really necessary for liquids, as their properties do not vary with pressure. 4. allowable pressure drop for both streams. This is a very important parameter for heat exchanger design. Generally, for liquids, a value of 0.5–0.7 kg/cm2 is permitted per shell. A higher pressure drop is usually warranted for viscous liquids, especially in the tubeside. For gases, the allowed value is generally 0.05–0.2 kg/cm2, with 0.1 kg/cm2 being typical. 5. fouling resistance for both streams. If this is not furnished, the designer should adopt values specified in the TEMA standards or based on past experience. 6. physical properties of both streams. These include viscosity, thermal conductivity, density, and specific heat, preferably at both inlet and outlet temperatures. Viscosity data must be supplied at inlet and outlet temperatures, especially for liquids, since the variation with temperature may be considerable and is irregular (neither linear nor log-log). 7. heat duty. The duty specified should be consistent for both the shellside and the tubeside. 8. type of heat exchanger. If not furnished, the designer can choose this based upon the characteristics of the various types of construction described earlier. In fact, the designer is normally in a better position than the process engineer to do this. 9. line sizes. It is desirable to match nozzle sizes with line sizes to avoid expanders or reducers. However, sizing criteria for nozzles are usually more stringent than for lines, especially for the shellside inlet. Conse-

quently, nozzle sizes must sometimes be one size (or even more in exceptional circumstances) larger than the corresponding line sizes, especially for small lines. 10. preferred tube size. Tube size is designated as O.D. × thickness × length. Some plant owners have a preferred O.D. × thickness (usually based upon inventory considerations), and the available plot area will determine the maximum tube length. Many plant owners prefer to standardize all three dimensions, again based upon inventory considerations. 11. maximum shell diameter. This is based upon tube-bundle removal requirements and is limited by crane capacities. Such limitations apply only to exchangers with removable tube bundles, namely U-tube and floating-head. For fixed-tubesheet exchangers, the only limitation is the manufacturer’s fabrication capability and the availability of components such as dished ends and flanges. Thus, floating-head heat exchangers are often limited to a shell I.D. of 1.4–1.5 m and a tube length of 6 m or 9 m, whereas fixedtubesheet heat exchangers can have shells as large as 3 m and tubes lengths up to 12 m or more. 12. materials of construction. If the tubes and shell are made of identical materials, all components should be of this material. Thus, only the shell and tube materials of construction need to be specified. However, if the shell and tubes are of different metallurgy, the materials of all principal components should be specified to avoid any ambiguity. The principal components are shell (and shell cover), tubes, channel (and channel cover), tubesheets, and baffles. Tubesheets may be lined or clad. 13. special considerations. These include cycling, upset conditions, alternative operating scenarios, and whether operation is continuous or intermittent.

Tubeside design Tubeside calculations are quite straightforward, since tubeside flow

CHEMICAL ENGINEERING PROGRESS • FEBRUARY 1998

represents a simple case of flow through a circular conduit. Heat-transfer coefficient and pressure drop both vary with tubeside velocity, the latter more strongly so. A good design will make the best use of the allowable pressure drop, as this will yield the highest heat-transfer coefficient. If all the tubeside fluid were to flow through all the tubes (one tube pass), it would lead to a certain velocity. Usually, this velocity is unacceptably low and therefore has to be increased. By incorporating pass partition plates (with appropriate gasketing) in the channels, the tubeside fluid is made to flow several times through a fraction of the total number of tubes. Thus, in a heat exchanger with 200 tubes and two passes, the fluid flows through 100 tubes at a time, and the velocity will be twice what it would be if there were only one pass. The number of tube passes is usually one, two, four, six, eight, and so on.

Viscosity influences the heat-transfer coefficient in two opposing ways — as a parameter of the Reynolds number, and as a parameter of Prandtl number. Thus, from Eq. 1c: h α (µ)0.33–0.8 h α (µ)–0.47 (2a) (2b)

In other words, the heat-transfer coefficient is inversely proportional to viscosity to the 0.47 power. Similarly, the heat-transfer coefficient is directly proportional to thermal conductivity to the 0.67 power. These two facts lead to some interesting generalities about heat transfer. A high thermal conductivity promotes a high heat-transfer coefficient. Thus,

cooling water (thermal conductivity of around 0.55 kcal/h•m•°C) has an extremely high heat-transfer coefficient of typically 6,000 kcal/h•m2•°C, followed by hydrocarbon liquids (thermal conductivity between 0.08 and 0.12 kcal/h•m•°C) at 250–1,300 kcal/h•m2•°C, and then hydrocarbon gases (thermal conductivity between 0.02 and 0.03 kcal/h•m•°C) at 50–500 kcal/h•m2•°C. Hydrogen is an unusual gas, because it has an exceptionally high thermal conductivity (greater than that of hydrocarbon liquids). Thus, its heat-transfer coefficient is toward the upper limit of the range for hydrocarbon liquids. The range of heat-transfer coefficients for hydrocarbon liquids is

Pass Partition

Stationary Tubesheet

Shell

Tie Rods and Spacers

Floating Tubesheet

Shell Cover

Heat-transfer coefficient The tubeside heat-transfer coefficient is a function of the Reynolds number, the Prandtl number, and the tube diameter. These can be broken down into the following fundamental parameters: physical properties (namely viscosity, thermal conductivity, and specific heat); tube diameter; and, very importantly, mass velocity. The variation in liquid viscosity is quite considerable; so, this physical property has the most dramatic effect on heat-transfer coefficient. The fundamental equation for turbulent heat-transfer inside tubes is:
Nu = 0.027 (Re)0.8 (Pr)0.33 or (hD/k) = 0.027 (DG/µ)0.8 (cµ/k)0.33 Rearranging: h = 0.027(DG/µ)0.8(cµ/k)0.33(k/D) (1c) (1b) (1a)

Stationary-Head Channel

Support Saddles Baffles

Floating-Head Cover

s Figure 4. Pull-through floating-head exchanger with backing device (TEMA S).

Pass Partition

Tie Rods and Spacers

Shell

Floating Tubesheet

Floating-Head Cover

Weir

Stationary-Head Channel

Support Saddle

Baffles

Support Saddle

Shell Cover

s Figure 5. Pull-through floating-head exchanger (TEMA T).
FEBRUARY 1998 • CHEMICAL ENGINEERING PROGRESS

S H E L L- A N D - T U B E H E AT E X C H A N G E R S

rather large due to the large variation in their viscosity, from less than 0.1 cP for ethylene and propylene to more than 1,000 cP or more for bitumen. The large variation in the heat-transfer coefficients of hydrocarbon gases is attributable to the large variation in operating pressure. As operating pressure rises, gas density increases. Pressure drop is directly proportional to the square of mass velocity and inversely proportional to density. Therefore, for the same pressure drop, a higher mass velocity can be maintained when the density is higher. This larger mass velocity translates into a higher heat-transfer coefficient.

Table 1. Heat exchanger service for Example 1.
Shellside Fluid Flow rate, kg/h Temperature in/out, °C Operating pressure, kg/cm2 (abs.) Allowable pressure drop, kg/cm2 Fouling resistance, h•m2•°C/kcal Heat duty, MM kcal/h Viscosity in/out, cP Design pressure, kg/cm2 (gage) Line size, mm (nominal) Material of construction Crude oil 399,831 227 / 249 28.3 1.2 0.0007 5.4945 0.664 / 0.563 44.0 300 Carbon steel Tubeside Heavy gas oil circulating reflux 277,200 302 / 275 13.0 0.7 0.0006 5.4945 0.32 / 0.389 17.0 300 Tubes: Type 410 stainless steel Other: 5Cr Mo

Pressure drop Mass velocity strongly influences the heat-transfer coefficient. For turbulent flow, the tubeside heat-transfer coefficient varies to the 0.8 power of tubeside mass velocity, whereas tubeside pressure drop varies to the square of mass velocity. Thus, with increasing mass velocity, pressure drop increases more rapidly than does the heat-transfer coefficient. Consequently, there will be an optimum mass velocity above which it will be wasteful to increase mass velocity further. Furthermore, very high velocities lead to erosion. However, the pressure drop limitation usually becomes controlling long before erosive velocities are attained. The minimum recommended liquid velocity inside tubes is 1.0 m/s, while the maximum is 2.5–3.0 m/s. Pressure drop is proportional to the square of velocity and the total length of travel. Thus, when the number of tube passes is increased for a given number of tubes and a given tubeside flow rate, the pressure drop rises to the cube of this increase. In actual practice, the rise is somewhat less because of lower friction factors at higher Reynolds numbers, so the exponent should be approximately 2.8 instead of 3. Tubeside pressure drop rises steeply with an increase in the number of tube passes. Consequently, it often happens

that for a given number of tubes and two passes, the pressure drop is much lower than the allowable value, but with four passes it exceeds the allowable pressure drop. If in such circumstances a standard tube has to be employed, the designer may be forced to accept a rather low velocity. However, if the tube diameter and length may be varied, the allowable pressure drop can be better utilized and a higher tubeside velocity realized. The following tube diameters are usually used in the CPI: w, , e, , 1, 1 , and 1 in. Of these, in. and 1 in. are the most popular. Tubes smaller than in. O.D. should not be used for fouling services. The use of small-diameter tubes, such as in., is warranted only for small heat exchangers with heat-transfer areas less than 20–30 m2. It is important to realize that the total pressure drop for a given stream must be met. The distribution of pressure drop in the various heat exchangers for a given stream in a particular circuit may be varied to obtain good heat transfer in all the heat exchangers. Consider a hot liquid stream flowing through several preheat exchangers. Normally, a pressure drop of 0.7 kg/cm2 per shell is permitted for liquid streams. If there are five such preheat exchangers, a total pressure drop of 3.5 kg/cm2 for the circuit would be

permitted. If the pressure drop through two of these exchangers turns out to be only 0.8 kg/cm2, the balance of 2.7 kg/cm2 would be available for the other three.

Example 1: Optimizing tubeside design Consider the heat exchanger service specified in Table 1. A TEMA Type AES exchanger (split-ring pullthrough floating-head construction) was to be employed. Tubes were to be either 25 mm O.D. (preferred) or 20 mm O.D., 2 mm thick, and 9 m long (but could be shorter). A first design was produced using 25-mm-O.D. × 9-m tubes (Case A in Table 2). The tubeside pressure drop was only 0.17 kg/cm2 even though 0.7 kg/cm2 was permitted. Further, the tubeside heat-transfer resistance was 27.71% of the total, which meant that if the allowable pressure drop were better utilized, the heat-transfer area would decrease. However, when the number of tube passes was increased from two to four (keeping the shell diameter the same and decreasing the number of tubes from 500 to 480 due to the extra pass-partition lanes), the tubeside pressure drop increased to 1.06 kg/cm2, which was unacceptable. (The shellside design was satisfactory, with the allowable pressure drop quite well utilized.)

CHEMICAL ENGINEERING PROGRESS • FEBRUARY 1998

Table 2. Details of two designs for Example 1.
Case A Shell I.D., mm Tube O.D. × Number of tubes × Number of tube passes Heat-transfer area, m2 Tube pitch × Tube layout angle Baffle type Baffle spacing, mm Baffle cut, percent of diameter Velocity, m/s Shellside Tubeside Heat-transfer coefficient, kcal/h•m2•°C Shellside Tubeside Pressure drop, kg/cm2 Shellside Tubeside Resistance, % Shellside film Tubeside film Fouling Metal wall Overdesign 17.24 27.71 50.35 4.69 8.29 15.84 21.14 57.66 4.87 4.87 0.86 0.17 1.2 0.51 2,065 1,285 2,511 1,976 1.15 1.36 1.52 2.17 925 25 × 500 × 2 343 32 × 90° Single-segmental 450 25 Case B 780 20 × 540 × 2 300 26 × 90° Single-segmental 400 30

m/s earlier), pressure drop (0.51 kg/cm2 vs. 0.17 kg/cm2), and heattransfer coefficient (1,976 vs. 1,285 kcal/h•m2•°C) were all much higher. The overall heat-transfer coefficient for this design was 398 kcal/h•m2•°C vs. 356 for Case A.

Stepwise calculations for viscous liquids When the variation in tubeside viscosity is pronounced, a single-point calculation for the tubeside heattransfer coefficient and pressure drop will give unrealistic results. This is particularly true in cases where a combination of turbulent (or transition) flow and laminar flow exist, since the thermal performance is very different in these two regimes. In such cases, it will be necessary to perform the calculations stepwise or zone-wise. The number of steps or zones will be determined by the variation in the tubeside viscosity and thus the Reynolds number. Example 2: Stepwise calculations The principal process parameters for a kettle-type steam generator in a refinery are shown in Table 3. The viscosity of the heavy vacuum gas oil varies from 1.6 cP at the inlet to 6.36 cP at the outlet. A design was produced without performing the calculations stepwise — that is, on the basis of a single average temperature and corresponding physical properties. Details of this design are shown in Table 4. Performing the tubeside calculations stepwise, in ten equal heat duty steps, revealed that the original exchanger was undersurfaced. The relevant performance parameters for the single-point and stepwise calculations are compared in Table 5. The main reason for the difference was the variation in Reynolds number, from 9,813 in the first zone to 2,851 in the last zone. In addition, the mean temperature difference (MTD) decreased drastically, from 138.47°C in the first zone to a mere

Table 3. Process parameters for Example 2.
Shellside Fluid Flow rate, kg/h Temperature in/out, °C Allowable pressure drop, kg/cm2 Fouling resistance, Viscosity in/out, cP Design pressure, kg/cm2 (gage) Heat duty, kcal/h h•m2•°C/kcal Boiler feedwater, Steam 23,100 (fully vaporized) 154 / 154 Negligible 0.0002 0.176 / 0.176 6.5 11,242,000 Tubeside Heavy vacuum gas oil 129,085 299 / 165 1.4 0.0006 1.6 / 6.36 21.3 11,242,000

Since the overdesign in the fourpass configuration was 28.1%, an attempt was made to reduce the tubeside pressure drop by decreasing the tube length. When the tube length was reduced to 7.5 m, the overdesign was 5.72%, but the tubeside pressure drop was 0.91 kg/cm2, which was

still higher than that permitted. Next, a design with 20-mm-O.D. tubes was attempted (Case B in Table 2). The shell diameter and heat-transfer surface decreased considerably, from 925 mm to 780 mm, and from 343 m2 to 300 m2, respectively. The tubeside velocity (2.17 m/s vs. 1.36

FEBRUARY 1998 • CHEMICAL ENGINEERING PROGRESS

S H E L L- A N D - T U B E H E AT E X C H A N G E R S

17.04°C in the last. Thus, while the initial zones (the hot end) had both a high heat-transfer coefficient and a high MTD, these decreased progressively toward the outlet (cold) end of the exchanger. Consequently, while the first zone required a length of only 2.325 m, the last zone required a length of 44.967 m, even though the heat duties were the same. The tubeside pressure drop was only marginally higher by the stepwise method, because the tubeside is entirely in the transition regime (Re between 2,851 and 9,813).

Table 4. Design produced for Example 2 without stepwise calculations.
Number of kettles Kettle/port I.D., mm Tubes per kettle 2 (in parallel) 1,825 / 1,225 790 tubes Type 316 stainless steel 25 mm O.D. × 2 mm thick × 9 m long 12 32 mm square (90°) Full support plates only Shellside: inlet 75, outlet 3 × 200 Tubeside: 150 1,104 (2 × 552)

Number of tube passes Tube pitch Baffling Connections, mm (nominal) Heat-transfer area, m2

Shellside design The shellside calculations are far more complex than those for the tubeside. This is mainly because on the shellside there is not just one flow stream but one principal cross-flow stream and four leakage or bypass streams. There are various shellside flow arrangements, as well as various tube layout patterns and baffling designs, which together determine the shellside stream analysis. Shell configuration TEMA defines various shell patterns based on the flow of the shellside fluid through the shell: E, F, G, H, J, K, and X (see Figure 1). In a TEMA E single-pass shell, the shellside fluid enters the shell at one end and leaves from the other end. This is the most common shell type — more heat exchangers are built to this configuration than all other configurations combined. A TEMA F two-pass shell has a longitudinal baffle that divides the shell into two passes. The shellside fluid enters at one end, traverses the entire length of the exchanger through one-half the shell cross-sectional area, turns around and flows through the second pass, then finally leaves at the end of the second pass. The longitudinal baffle stops well short of the tubesheet, so that the fluid can flow into the second pass. The F shell is used for temperature-cross situations — that is, where

Table 5. Performance parameters for Example 2 using single-point and stepwise calculations.
Single-point Calculations Tubeside heat-transfer coefficient, kcal/h•m2•°C Overall heat-transfer coefficient, kcal/h•m2•°C Tubeside pressure drop, kg/cm2 Overdesign, % 347.9 244.7 1.28 24.03 Stepwise Calculations 229.2 179.3 1.35 –9.11

the cold stream leaves at a temperature higher than the outlet temperature of the hot stream. If a two-pass (F) shell has only two tube passes, this becomes a true countercurrent arrangement where a large temperature cross can be achieved. A TEMA J shell is a divided-flow shell wherein the shellside fluid enters the shell at the center and divides into two halves, one flowing to the left and the other to the right and leaving separately. They are then combined into a single stream. This is identified as a J 1–2 shell. Alternatively, the stream may be split into two halves that enter the shell at the two ends, flow toward the center, and leave as a single stream, which is identified as a J 2–1 shell. A TEMA G shell is a split-flow shell (see Figure 1). This construction is usually employed for horizontal thermosyphon reboilers. There is only a central support plate and no baffles. A G shell cannot be used for heat ex-

changers with tube lengths greater than 3 m, since this would exceed the limit on maximum unsupported tube length specified by TEMA — typically 1.5 m, though it varies with tube O.D., thickness, and material. When a larger tube length is needed, a TEMA H shell (see Figure 1) is used. An H shell is basically two G shells placed side-by-side, so that there are two full support plates. This is described as a double-split configuration, as the flow is split twice and recombined twice. This construction, too, is invariably employed for horizontal thermosyphon reboilers. The advantage of G and H shells is that the pressure drop is drastically less and there are no cross baffles. A TEMA X shell (see Figure 1) is a pure cross-flow shell where the shellside fluid enters at the top (or bottom) of the shell, flows across the tubes, and exits from the opposite side of the shell. The flow may be introduced through multiple nozzles

CHEMICAL ENGINEERING PROGRESS • FEBRUARY 1998

located strategically along the length of the shell in order to achieve a better distribution. The pressure drop will be extremely low — in fact, there is hardly any pressure drop in the shell, and what pressure drop there is, is virtually all in the nozzles. Thus, this configuration is employed for cooling or condensing vapors at low pressure, particularly vacuum. Full support plates can be located if needed for structural integrity; they do not interfere with the shellside flow because they are parallel to the flow direction. A TEMA K shell (see Figure 1) is a special cross-flow shell employed for kettle reboilers (thus the K). It has an integral vapor-disengagement space embodied in an enlarged shell. Here, too, full support plates can be employed as required.

Tube layout patterns There are four tube layout patterns, as shown in Figure 6: triangular (30°), rotated triangular (60°), square (90°), and rotated square (45°). A triangular (or rotated triangular) pattern will accommodate more tubes than a square (or rotated square) pat-

Triangular (30 ˚)

Rotated Triangular (60˚)

Square (90˚)

Rotated Square (45˚)

s Figure 6. Tube layout patterns.

tern. Furthermore, a triangular pattern produces high turbulence and therefore a high heat-transfer coefficient. However, at the typical tube pitch of 1.25 times the tube O.D., it does not permit mechanical cleaning of tubes, since access lanes are not available. Consequently, a triangular layout is limited to clean shellside services. For services that require mechanical cleaning on the shellside, square patterns must be used. Chemical cleaning does not require access lanes, so a triangular layout may be used for dirty shellside services provided chemical cleaning is suitable and effective. A rotated triangular pattern seldom offers any advantages over a triangular pattern, and its use is consequently not very popular. For dirty shellside services, a square layout is typically employed. However, since this is an in-line pattern, it produces lower turbulence. Thus, when the shellside Reynolds number is low (< 2,000), it is usually advantageous to employ a rotated square pattern because this produces much higher turbulence, which results in a higher efficiency of conversion of pressure drop to heat transfer. As noted earlier, fixed-tubesheet construction is usually employed for clean services on the shellside, Utube construction for clean services on the tubeside, and floating-head construction for dirty services on both the shellside and tubeside. (For clean services on both shellside and tubeside, either fixed-tubesheet or U-tube construction may be used, although U-tube is preferable since it permits differential expansion between the shell and the tubes.) Hence, a triangular tube pattern may be used for fixed-tubesheet exchangers and a square (or rotated square) pattern for floating-head exchangers. For U-tube exchangers, a triangular pattern may be used provided the shellside stream is clean and a square (or rotated square) pattern if it is dirty.

Tube pitch Tube pitch is defined as the shortest distance between two adjacent tubes. For a triangular pattern, TEMA specifies a minimum tube pitch of 1.25 times the tube O.D. Thus, a 25mm tube pitch is usually employed for 20-mm O.D. tubes. For square patterns, TEMA additionally recommends a minimum cleaning lane of in. (or 6 mm) between adjacent tubes. Thus, the minimum tube pitch for square patterns is either 1.25 times the tube O.D. or the tube O.D. plus 6 mm, whichever is larger. For example, 20-mm tubes should be laid on a 26-mm (20 mm + 6 mm) square pitch, but 25-mm tubes should be laid on a 31.25-mm (25 mm × 1.25) square pitch. Designers prefer to employ the minimum recommended tube pitch, because it leads to the smallest shell diameter for a given number of tubes. However, in exceptional circumstances, the tube pitch may be increased to a higher value, for example, to reduce shellside pressure drop. This is particularly true in the case of a cross-flow shell. Baffling Type of baffles. Baffles are used to support tubes, enable a desirable velocity to be maintained for the shellside fluid, and prevent failure of tubes due to flow-induced vibration. There are two types of baffles: plate and rod. Plate baffles may be single-segmental, double-segmental, or triple-segmental, as shown in Figure 7. Baffle spacing. Baffle spacing is the centerline-to-centerline distance between adjacent baffles. It is the most vital parameter in STHE design. The TEMA standards specify the minimum baffle spacing as one-fifth of the shell inside diameter or 2 in., whichever is greater. Closer spacing will result in poor bundle penetration by the shellside fluid and difficulty in mechanically cleaning the outsides of the tubes. Furthermore, a low baffle spacing results in a poor stream distribution as will be explained later.

FEBRUARY 1998 • CHEMICAL ENGINEERING PROGRESS

S H E L L- A N D - T U B E H E AT E X C H A N G E R S

Single Segmental Baffles

Double Segmental Baffles

Triple Segmental Baffles

No-Tubes-in-Window Segmental Baffles

Rod Baffle

s Figure 7. Types of baffles. The maximum baffle spacing is the shell inside diameter. Higher baffle spacing will lead to predominantly longitudinal flow, which is less efficient than cross-flow, and large unsupported tube spans, which will make the exchanger prone to tube failure due to flow-induced vibration. Optimum baffle spacing. For turbulent flow on the shellside (Re > 1,000), the heat-transfer coefficient varies to the 0.6–0.7 power of velocity; however, pressure drop varies to the 1.7–2.0 power. For laminar flow (Re < 100), the exponents are 0.33 for the heat-transfer coefficient and 1.0 for pressure drop. Thus, as baffle spacing is reduced, pressure drop increases at a much faster rate than does the heat-transfer coefficient. This means that there will be an optimum ratio of baffle spacing to shell inside diameter that will result in the highest efficiency of conversion of pressure drop to heat transfer. This optimum ratio is normally between 0.3 and 0.6. Baffle cut. As shown in Figure 8, baffle cut is the height of the segment that is cut in each baffle to permit the shellside fluid to flow across the baffle. This is expressed as a percentage of the shell inside diameter. Although this, too, is an important parameter for STHE design, its effect is less profound than that of baffle spacing. Baffle cut can vary between 15% and 45% of the shell inside diameter. Both very small and very large baffle cuts are detrimental to efficient heat transfer on the shellside due to large deviation from an ideal situation, as illustrated in Figure 9. It is strongly recommended that only baffle cuts between 20% and 35% be employed. Reducing baffle cut below 20% to increase the shellside heat-transfer coefficient or increasing the baffle cut beyond 35% to decrease the shellside pressure drop usually lead to poor designs. Other aspects of tube bundle geometry should be changed instead to achieve those goals. For example, doublesegmental baffles or a divided-flow shell, or even a cross-flow shell, may be used to reduce the shellside pressure drop. For single-phase fluids on the shellside, a horizontal baffle cut (Figure 10) is recommended, because this minimizes accumulation of deposits at the bottom of the shell and also prevents stratification. However, in the case of a two-pass shell (TEMA F), a vertical cut is preferred for ease of fabrication and bundle assembly. Baffling is discussed in greater detail in (2) and (3).

Equalize cross-flow and window velocities Flow across tubes is referred to as cross-flow, whereas flow through the window area (that is, through the baffle cut area) is referred to as window flow. The window velocity and the cross-flow velocity should be as close as possible — preferably within 20%

Baffle Cut

Baffle

s Figure 8. Baffle cut.

CHEMICAL ENGINEERING PROGRESS • FEBRUARY 1998

Main Flow

Eddies Baffle

Shell Diameter

Eddies Baffle

Main Flow

Baffle

a. Small Baffle Cut

b. Large Baffle Cut

c. Ideal Baffle Cut and Baffle Spacing

s Figure 9. Effect of small and large baffle cuts. of each other. If they differ by more than that, repeated acceleration and deceleration take place along the length of the tube bundle, resulting in inefficient conversion of pressure drop to heat transfer. transfer, the other streams are not as effective. The A stream is fairly efficient, because the shellside fluid is in contact with the tubes. Similarly, the C stream is in contact with the peripheral tubes around the bundle, and the F stream is in contact with the tubes along the pass-partition lanes. Consequently, these streams also experience heat transfer, although at a lower efficiency than the B stream. However, since the E stream flows along the shell wall, where there are no tubes, it encounters no heat transfer at all. The fractions of the total flow represented by these five streams can be determined for a particular set of exchanger geometry and shellside flow conditions by any sophisticated heatexchanger thermal design software. Essentially, the five streams are in parallel and flow along paths of varying hydraulic resistances. Thus, the flow fractions will be such that the pressure drop of each stream is identical, since all the streams begin and end at the inlet and outlet nozzles. Subsequently, based upon the efficiency of each of these streams, the overall shellside stream efficiency and thus the shellside heat-transfer coefficient is established. Since the flow fractions depend strongly upon the path resistances, varying any of the following construction parameters will affect stream analysis and thereby the shellside performance of an exchanger: • baffle spacing and baffle cut; • tube layout angle and tube pitch; • number of lanes in the flow direction and lane width; • clearance between the tube and the baffle hole; • clearance between the shell I.D. and the baffle; and • location of sealing strips and sealing rods.

Shellside stream analysis On the shellside, there is not just one stream, but a main cross-flow stream and four leakage or bypass streams, as illustrated in Figure 11. Tinker (4) proposed calling these streams the main cross-flow stream (B), a tube-to-baffle-hole leakage stream (A), a bundle bypass stream (C), a pass-partition bypass stream (F), and a baffle-to-shell leakage stream (E). While the B (main cross-flow) stream is highly effective for heat

Horizontal Cut

A

A
B C C

C

F B B B B

C

B Vertical Cut A E

E

s Figure 10. Baffle cut orientation.

s Figure 11. Shellside flow distribution.
FEBRUARY 1998 • CHEMICAL ENGINEERING PROGRESS

S H E L L- A N D - T U B E H E AT E X C H A N G E R S

Using a very low baffle spacing tends to increase the leakage and bypass streams. This is because all five shellside streams are in parallel and, therefore, have the same pressure drop. The leakage path dimensions are fixed. Consequently, when baffle spacing is decreased, the resistance of the main cross-flow path and thereby its pressure drop increases. Since the pressure drops of all five streams must be equal, the leakage and bypass streams increase until the pressure drops of all the streams balance out. The net result is a rise in the pressure drop without a corresponding increase in the heat-transfer coefficient. The shellside fluid viscosity also affects stream analysis profoundly. In addition to influencing the shellside heat transfer and pressure drop performance, the stream analysis also affects the mean temperature difference (MTD) of the exchanger. This will be discussed in detail later. First, though, let’s look at an example that demonstrates how to optimize baffle design when there is no significant temperature profile distortion.

Table 6. Process parameters for Example 3.
Shellside Fluid Flow rate, kg/h Temperature in/out, °C Heat duty, MM kcal/h Density in/out, kg/m3 Viscosity in/out, cP Specific heat in/out, kcal/kg•°C Allowable pressure drop, kg/cm2 Fouling resistance, h•m2•°C/kcal Design pressure, kg/cm2 (gage) Design temperature, °C Line size, mm (nominal) Material of construction Crude oil 367,647 209 / 226 4.0 730 / 715 0.52 / 0.46 0.63 / 0.65 1.0 0.0006 36.6 250 300 Carbon steel Tubeside Heavy gas oil circulating reflux 105,682 319 / 269 4.0 655 / 700 0.27 / 0.37 0.78 / 0.73 0.073 / 0.0795 0.7 0.0006 14.0 340 150 5Cr Mo

Thermal conductivity in/out, kcal/h•m•°C 0.087 / 0.085

Table 7. Effects of varying baffle spacing for a constant 25% baffle cut for Example 3.
Design A Baffle spacing, mm Tube-to-baffle-hole leakage (A), fraction Main cross-flow stream (B), fraction Bundle bypass stream (C), fraction Baffle-to-shell leakage stream (E), fraction Pass-partition bypass stream (F), fraction Overall shellside heat-transfer efficiency, % Shellside velocity, m/s Cross-flow Window flow Shellside pressure drop, kg/cm2 Heat-transfer coefficient, kcal/h•m2•°C Shellside Tubeside Overall Overdesign, % 2,578 1,402 401.8 7.58 2,498 1,402 399.8 7.08 2,372 1,402 396.5 6.21 2.5 2.34 1.34 2.15 2.34 1.03 1.87 2.34 0.79 300 0.157 0.542 0.113 0.12 0.069 71.3 Design B 350 0.141 0.563 0.116 0.109 0.072 73.4 Design C 400 0.13 0.577 0.119 0.1 0.075 74.9

Example 3: Optimizing baffle design Consider the heat exchanger service specified in Table 6. Since there are two independent variables — baffle spacing and baffle cut — we will first keep the baffle cut constant at 25% and vary the baffle spacing (Table 7). Later, the baffle spacing will be kept constant and the baffle cut varied (Table 8). In real practice, both parameters should be varied simultaneously, but keeping one parameter constant and varying the other will more vividly demonstrate the influence of each parameter. The first design developed is designated Design A in Table 7. Here, the baffle cut is 25% and the baffle spacing is 300 mm. In Designs B and C, the baffle spacing was changed to 350 mm and 400 mm, respectively. There is no temperature profile distortion problem with these designs. Notice that as the baffle spacing is

increased from 300 mm to 400 mm, the main cross-flow, bundle bypass, and pass-partition bypass streams increase progressively, whereas the tube-to-baffle-hole leakage and baffle-to-shell leakage streams decrease progressively. The overall heat-transfer efficiency of the shellside stream increases progressively. Neverthe-

less, since the shellside velocity and the Reynolds number decrease, both the shellside heat-transfer coefficient and the shellside pressure drop decrease, but the former at a much lower rate than the latter. Since the allowable shellside pressure drop is 1.0 kg/cm2, Design A is ruled out, as its shellside pressure drop far ex-

CHEMICAL ENGINEERING PROGRESS • FEBRUARY 1998

Table 8. Effects of varying baffle cut for a constant 400-mm baffle spacing for Example 3.
Design D Baffle cut, percent of diameter Tube-to-baffle-hole leakage (A), fraction Main cross-flow stream (B), fraction Bundle bypass stream (C), fraction Baffle-to-shell leakage stream (E), fraction Pass-partition bypass stream (F), fraction Overall shellside heat-transfer efficiency, % Shellside velocity, m/s Cross-flow Window flow Shellside pressure drop, Shellside Tubeside Overall Overdesign, % kg/cm2 Heat-transfer coefficient, kcal/h•m2•°C 2,372 1,402 396.5 6.21 2,200 1,402 391.4 4.86 2,074 1,402 387.3 3.76 1,929 1,402 381.9 2.33 2,406 1,402 397.4 6.43 1.87 2.34 0.79 1.87 1.86 0.69 1.87 1.65 0.65 1.87 1.48 0.6 1.87 3.09 0.98 25 0.13 0.577 0.119 0.1 0.075 74.9 Design E 30 0.106 0.612 0.122 0.091 0.069 73.0 Design F 33 0.093 0.643 0.118 0.085 0.062 75.7 Design G 36 0.08 0.674 0.117 0.078 0.052 78.6 Design H 20 0.159 0.54 0.126 0.114 0.061 72.7

ceeds this limit. Designs B and C are both acceptable. The overdesign varies marginally. Thus, it would be prudent to adopt Design C, since it has a lower pressure drop and a better stream analysis. Now consider the effect of varying the baffle cut while keeping the baffle spacing constant at 400 mm, as shown in Table 8. As the baffle cut is progressively increased from 25% in Design D to 36% in Design G, the following changes are observed: • the main cross-flow stream (B) fraction increases appreciably; • the tube-to-baffle-hole (A), baffle-to-shell (E), and pass-partition (F) stream fractions decrease steadily; • the bundle bypass (C) stream fraction remains steady; • the overall heat-transfer efficiency of the shellside stream first decreases and then increases; and • as the window velocity decreases, the shellside heat-transfer coefficient falls; the pressure drop also decreases, but not as fast as the heattransfer coefficient. These observations are reflected in the overdesign values. Design E ap-

pears to be the best choice, since Design D cannot be accepted because of the excessive shellside pressure drop.

Reducing ∆P by modifying baffle design Single-pass shell and single-segmental baffles. The first baffle alternative is the single-segmental baffle in a single-pass (TEMA E) shell. However, in many situations, the shellside pressure drop is too high with single-segmental baffles in a single-pass shell, even after increasing the baffle spacing and baffle cut to the highest values recommended. Such a situation may arise when handling a very high shellside flow rate or when the shellside fluid is a low-pressure gas. In these cases, the next alternative that should be considered is the double-segmental baffle (Figure 7). Single-pass shell and double-segmental baffles. By changing the baffling from single-segmental to doublesegmental at the same spacing in an otherwise identical heat exchanger, the cross-flow velocity is reduced approximately to half, because the shellside flow is divided into two parallel

streams. This greatly reduces the cross-flow pressure drop. However, the window velocity and therefore the window pressure drop cannot be reduced appreciably (assuming that the maximum recommended baffle cut was already tried with single-segmental baffles before switching to doublesegmental baffles). Nevertheless, since cross-flow pressure drop is invariably much greater than window pressure drop, there is an appreciable reduction in the total pressure drop. There is also a decrease in the shellside heat-transfer coefficient, but this is considerably less than the reduction in the pressure drop. The use of double-segmental baffles is covered in depth in (3). Divided-flow shell and single-segmental baffles. If the allowable shellside pressure drop cannot be satisfied even with double-segmental baffles at a relatively large spacing, a dividedflow shell (TEMA J) with single-segmental baffles (Figure 1) should be investigated next. Since pressure drop is proportional to the square of the velocity and to the length of travel, a divided-flow shell will have approximately

FEBRUARY 1998 • CHEMICAL ENGINEERING PROGRESS

S H E L L- A N D - T U B E H E AT E X C H A N G E R S

one-eighth the pressure drop in an otherwise identical single-pass exchanger. The advantage of a divided-flow shell over double-segmental baffles is that it offers an even larger reduction in pressure drop, since not only crossflow velocity but even window velocity can be reduced. The disadvantage is the increase in cost due to the additional piping required. Divided-flow shell and doublesegmental baffles. If even a dividedflow shell with single-segmental baffles is unable to meet the allowable shellside pressure drop limit, it will be necessary to adopt a combination of a divided-flow shell and doublesegmental baffles. With such a combination, a very large reduction in shellside pressure drop is possible — to as low as 4% of the pressure drop in a single-pass exchanger with the same baffle spacing and baffle cut. In sharp contrast, the heat-transfer coefficient will reduce to about 40%. No-tubes-in-window segmental baffles. As baffle spacing is increased to reduce the shellside pressure drop, an exchanger becomes more prone to tube failure due to flow-induced vibration. Exchangers with double-segmental baffles are less likely to experience such problems than those with single-segmental baffles. However, a vibration problem may persist even with double-segmental baffles. In such cases, a no-tubes-inwindow design (Figure 7) should be adopted. Here, each tube is supported by every baffle, so that the unsupported tube span is the baffle spacing. In exchangers with normal single-segmental baffles, the unsupported tube span is twice the baffle spacing. Should it become necessary to use a very large baffle spacing to restrict the shellside pressure drop to the permitted value, intermediate supports may be used to increase the natural frequency of the tubes, thus producing a design that is safe against tube failure due to flow-induced vibration. The no-tubes-in-window design requires a larger shell diameter for a given number of tubes. This esclates

its cost, typically by about 10%. The higher cost is offset to some extent by the higher shellside heat-transfer coefficient, since pure cross-flow is more efficient than the combination of cross-flow and window flow in conventional designs. Cross-flow shell. There are some services where the pressure drop limitation is so severe that none of the above shell/baffling configurations can yield a satisfactory design. A steam ejector condenser operating at a pressure of 50 mm Hg and having an allowable pressure drop of 5 mm Hg is an example. Such situations require the use of a cross-flow shell (TEMA X). Here, pure cross-flow takes place at a very low velocity, so there is virtually no pressure drop in the shell. Whatever pressure drop occurs is almost entirely in the nozzles. Support plates will be needed to meet TEMA requirements and prevent any possible flow-induced tube vibration. Since the shellside flow is parallel to these support plates, shellside pressure drop is not increased.

Temperature

Exchanger Length

s Figure 12. Countercurrent flow.

Increasing tube pitch For a given number of tubes, the smaller the tube pitch, the smaller the shell diameter, and therefore the lower the cost. Consequently, designers tend to pack in as many tubes as mechanically possible. As noted earlier, designers generally set the tube pitch at 1.25 times the tube O.D. For square or rotated square pitch, a minimum cleaning lane of in. or 6 mm is recommended by TEMA. As far as thermal-hydraulics are concerned, the optimum tube-pitchto-tube-diameter ratio for conversion of pressure drop to heat transfer is typically 1.25–1.35 for turbulent flow and around 1.4 for laminar flow. Increasing the tube pitch to reduce pressure drop is generally not recommended for two reasons. First, it increases the shell diameter and, thereby, the cost. Second, reducing pressure drop by modifying the baffle spacing, baffle cut, or shell type will result in a cheaper design.

Temperature

Exchanger Length

s Figure 13. Cocurrent flow. However, in the case of X shells, it may be necessary to increase the tube pitch above the TEMA minimum to meet pressure drop limitations, since there are no other parameters that can be modified.

Mean temperature difference Temperature difference is the driving force for heat transfer. When two streams flow in opposing directions across a tube wall, there is true countercurrent flow (Figure 12). In this situation, the only limitation is that the hot stream should at all points be hotter than the cold stream. The outlet temperature of the cold stream may be higher than the outlet temperature of the hot stream, as shown in Figure 12.

CHEMICAL ENGINEERING PROGRESS • FEBRUARY 1998

Since the temperature difference varies along the length of the heat exchanger, it has to be weighted to obtain a mean value for single-point determination of heat-transfer area. The logarithmic mean temperature difference (LMTD) represents this weighted value. If the hot and cold streams flow in the same direction, flow is cocurrent (Figure 13). The mean temperature difference is still represented by the LMTD. However, the LMTD for cocurrent flow is lower than that for countercurrent flow for the same terminal differences. This is because although one terminal temperature difference is very high, the other is far too low — that is, the temperature differences along the path of heat transfer are not balanced. What is even more serious with cocurrent flow is that the outlet temperature of the cold stream must be somewhat lower than the outlet temperature of the hot stream, which is a serious limitation. Consequently, countercurrent flow is always preferred to cocurrent flow. These principles apply only to single-pass exchangers. However, as noted earlier, shell-and-tube heat exchangers invariably have two or more tube passes. Since the shellside fluid flows in one direction, half the tube passes experience countercurrent flow and the other half experience cocurrent flow. The MTD for this situation is neither the LMTD for countercurrent flow nor that for cocurrent flow, but a value between the two. A correction factor, Ft, which depends on the four terminal temperatures and the shell style can be determined from charts in the TEMA standards. The LMTD for countercurrent flow is multiplied by this factor to obtain the corrected MTD. An important limitation for 1-2 shells (one shell pass and two or more tube passes) is that the outlet temperature of the cold stream cannot exceed the outlet temperature of the hot stream. This is because of the presence of one or more cocurrent passes. In re-

ality, a very small temperature difference is possible, but this represents an area of uncertainty and the credit is very small, so it is usually ignored. When there is a temperature cross (that is, the outlet temperature of the cold stream is higher than the outlet temperature of the hot stream), and pure countercurrent flow is not possible, multiple shells in series must be used. This will be discussed in detail in the followup article scheduled to be published in the next issue. An F shell has two passes, so if there are two tube passes, this is a pure countercurrent situation. However, if an F shell has four or more tube passes, it is no longer a true countercurrent situation and, hence, the Ft correction has to be applied. An F shell having four or more tube passes is represented as a 2-4 shell. The Ft factor for a 2-4 shell is identical to that for two 1-2 shells in series or two shell passes. The TEMA Ft factor chart for three shell passes really represents three shells in series, that for four shell passes four shells in series, and so on. It is important to realize that the LMTD and Ft factor concept assumes that there is no significant variation in the overall heat-transfer coefficient along the length of the shell. Howev-

er, there are some services where this is not true. An example of this is the cooling of a viscous liquid — as the liquid is cooled, its viscosity increases, and this results in a progressive reduction in the shellside heat-transfer coefficient. In this case, the simplistic overall MTD approach will be inaccurate, and the exchanger must be broken into several sections and the calculations performed zone-wise.

Temperature profile distortion An important issue that has not been considered so far is the temperature profile distortion. As noted earlier, the leakage and bypass streams are less efficient for heat transfer than the main cross-flow stream. Consider a case where the shellside stream is the cold fluid. Since the main cross-flow stream encounters a very large fraction of the total heattransfer surface, it has to pick up a very large part of the total heat duty. Assume that the cross-flow stream is 58% of the total shellside stream, but that it comes in contact with 80% of the tubes. As a result, its temperature rises more rapidly than if the entire shellside stream were to pick up the entire heat duty. Therefore, its temper-

Tubeside

Temperature

M

ross ain C

-flow

Strea

m

C Stre

am

nt Te Appare

mperatu

re Profi

le

E Stream Last Baffle Shellside C = Bundle-to-Shell Bypass E = Baffle-to-Shell Leakage

Exchanger Length

s Figure 14. Temperature profile distortion factor due to bypass and leakage.
FEBRUARY 1998 • CHEMICAL ENGINEERING PROGRESS

S H E L L- A N D - T U B E H E AT E X C H A N G E R S

ature profile will be steeper than that of the total stream (the apparent temperature profile) without considering the various flow fractions (Figure 14). The temperature profiles of the baffle-hole-to-tube leakage, shell-tobundle leakage, and pass-partition bypass streams will depend on their respective flow fractions and the fractional heat-transfer area encountered. However, since the shell-to-baffle leakage stream does not experience any heat transfer, the remaining four streams must pick up the entire heat duty, so that these four streams together will have a temperature profile steeper than that of the apparent stream. Consequently, the temperature difference between the hot and the cold streams will be lower all along the length of the heat exchanger, thereby resulting in the reduction of the MTD. This reduction in the MTD is known as the temperature profile distortion (or correction) factor. The temperature profile distortion factor is more pronounced when the leakage and bypass streams are high, especially the shell-to-baffle leakage stream, and the ratio of shellside temperature difference to the temperature approach at the shell outlet is high. The latter is because the closer the temperature approach at the shell outlet, the sharper the reduction in MTD.

Table 9. Process parameters for Example 4.
Shellside Fluid Flow rate, kg/h Temperature in/out, °C Heat duty, MM kcal/h Specific gravity in/out Viscosity in/out, cP Average specific heat, kcal/kg•°C Thermal conductivity in/out, kcal/h•m•°C Allowable pressure drop, kg/cm2 Fouling resistance, h•m2•°C/kcal Design pressure, kg/cm2 (gage) Design temperature, °C Material of construction Naphtha 9,841 114 / 40 0.46 0.62 / 0.692 0.254 / 0.484 0.632 0.092 / 0.101 0.7 0.0002 12.0 150 Carbon steel Tubeside Cooling water 65,570 33 / 40 0.46 1.0 / 1.0 0.76 / 0.66 1.0 0.542 / 0.546 0.7 0.0004 6.5 60 Admirality brass

Table 10. Construction parameters for Example 4.
Shell I.D. Tubes Number of tube passes Tube pitch Baffling Connections Heat-transfer area 500 mm 188 tubes, 20 mm O.D. × 2 mm thick × 6 m long 2 26 mm square (90°) Single-segmental, 140 mm spacing, 21% cut (diameter) 75 mm on shellside, 150 mm on tubeside 70 m2

Nomenclature c = stream specific heat, kcal/kg•°C D = tube inside diameter, m Ft = LMTD correction factor, dimensionless G = stream mass velocity, kg/m2•h h = stream heat-transfer coefficient, kcal/h•m2•°C k = stream thermal conductivity, kcal/h•m•°C Nu = Nusselt number = hD/k, dimensionless Pr = Prandtl number = cµ/k, dimensionless Re = Reynolds number = DG/µ, dimensionless Greek Letter µ = stream viscosity, kg/m•h

The leakage and bypass streams tend to be high when the shellside viscosity is high and when the baffle spacing is very low. Thus, care has to be exercised in the design of viscous liquid coolers such as a vacuum residue cooler in a crude oil refinery. The minimum recommended temperature profile distortion factor is 0.75. Below this, two or more shells in series must be employed. By using multiple shells in series, the ratio of shellside temperature difference to the temperature approach at the shell outlet is reduced. The mixing of the main cross-flow stream with the bypass and leakage streams after each shell reduces the penalty due to the distortion of the temperature profile and hence increases the temperature profile distortion factor.

In many situations, a temperature profile distortion factor is unavoidable, such as when cooling a viscous liquid over a large temperature range, and there is no alternative to the use of multiple shells in series. However, in many other situations, improper baffle spacing unnecessarily imposes such a penalty where it is easily avoidable. Designers normally tend to pack baffles as close as possible to get the maximum shellside heat-transfer coefficient, pressure drop permitting. In many such cases, the use of somewhat higher baffle spacing will reduce the shell-to-baffle leakage stream (the principal culprit) and hence improve the MTD correction factor appreciably, thereby producing a much better design.

CHEMICAL ENGINEERING PROGRESS • FEBRUARY 1998

Table 11. Detailed results of Example 4 iterations.
Existing Design Baffle spacing, mm Stream analysis, fraction of stream Baffle-hole-to-tube leakage (A) Main cross-flow (B) Shell-to-bundle leakage (C) Shell-to-baffle leakage (E) Pass-partition bypass stream (F) Overall shellside heat-transfer efficiency, % Temperature profile distortion factor Shellside velocity, m/s Shellside heat-transfer coefficient, kcal/h•m2•°C Shellside pressure drop, kg/cm2 Overall heat-transfer coefficient, kcal/h•m2•°C Mean temperature difference, °C Overdesign, % 0.189 0.463 0.109 0.24 0 62 0.6 0.15 614 0.034 380 13.73 –21.1 0.173 0.489 0.113 0.225 0 64.7 0.692 0.14 570 0.029 362 15.9 –12.8 0.163 0.506 0.116 0.215 0 66.4 0.735 0.13 562 0.027 359 16.87 –8.26 0.154 0.521 0.118 0.207 0 67.9 0.766 0.13 550 0.026 354 17.58 –5.73 0.143 0.539 0.121 0.196 0 69.7 0.794 0.12 512 0.023 338 18.22 –6.61 140 Alternative No. 1 160 Alternative No. 2 175 Alternative No. 3 190 Alternative No. 4 210

Example 4: Temperature distortion and baffle spacing
Consider an existing naphtha cooler in a refinery and petrochemical complex. The process parameters are listed in Table 9, and the construction parameters in Table 10. The existing design was undersurfaced by 21%, mainly because the temperature profile distortion factor was 0.6, which is lower than the minimum recommended value of 0.75. The existing design had a baffle spacing of 140 mm and a baffle cut of 21% (of the diameter). The shell-to-baffle leakage stream fraction was 0.24. To improve the design, the baffle spacing was progressively increased. The undersurfacing decreased with increasing baffle spacing, up to a spacing of 190 mm; thereafter, performance again started to deteriorate. Thus, 190 mm is the optimum baffle spacing. The detailed results of the various iterations are compared in CEP Table 11.

R. MUKHERJEE is assistant chief consultant in the Heat and Mass Transfer Dept. of Engineers India Ltd., New Delhi (011-91-11-371-6171; Fax: 011-91-11-371-5059l; e-mail: shilpi@giasdla.vsnl.net.in), where he has been employed since 1971. He has over 26 years of experience in the design, revamping, and troubleshooting of air-cooled and shelland-tube heat exchangers (especially for oil refineries, gas processing plants, and petrochemical plants), and also has considerable experience in heat-exchangernetwork synthesis and optimization. He has written several articles in technical journals and has presented two papers in the Industrial Session of the 10th International Heat Transfer Conference at Brighton in August 1994. He has served as faculty for several courses in heat exchanger design, energy conservation, and heat exchanger network optimization. He is an honors graduate in chemical engineering from Jadavpur Univ., Calcutta, and is a member of the Indian Institute of Chemical Engineers and the Indian Society for Heat and Mass Transfer.

Literature Cited
1. Tubular Exchanger Manufacturers Association, “Standards of the Tubular Exchanger Manufacturers Association,” 7th ed., TEMA, New York (1988). 2. Mukherjee, R., “Don’t Let Baffling Baffle You,” Chem. Eng. Progress, 92 (4), pp. 72–79 (Apr. 1996). 3. Mukherjee, R., “Use Double-Segmental Baffles in Shell-and-Tube Heat Exchangers,” Chem. Eng. Progress, 88 (11), pp. 47–52 (Nov. 1992). 4. Tinker, T., “Shellside Characteristics of Shell-and-tube Heat Exchangers: A Simplified Rating System for Commercial Heat Exchangers,” Trans. ASME, 80, pp. 36–52 (1958).

Further Reading
Kakac, S., et al., “Heat Exchangers: Thermal-Hydraulic Fundamentals and Design,” Hemisphere Publishing Corp., New York (1981). Schlunder, E.V., et al., eds., “Heat Exchanger Design Handbook,” Hemisphere Publishing Corp., New York (1983).

Acknowledgment The author is grateful to the management of Engineers India, Ltd., for permission to publish this article and acknowledges the use of Heat Transfer Research, Inc.’s software for the worked-out examples and their design methodology.

FEBRUARY 1998 • CHEMICAL ENGINEERING PROGRESS

Similar Documents

Premium Essay

Chem Sys

...SHELL & TUBE HEAT EXCHANGER DESIGN TFD-HE13 - Shell & Tube Heat Exchager Design 1 Introduction q Shell & tube heat exchangers are the most versatile type of heat exchangers. § They are used in process industries, in conventional and nuclear power stations, steam generators, etc § They are used in many alternative energy applications including ocean, thermal and geothermal. q Shell & tube heat exchangers provide relatively large ratios of heat transfer area to volume. They can be easily cleaned. q TFD-HE13 - Shell & Tube Heat Exchager Design 2 Shell & Tube Heat Exchangers q Shell & tube type heat exchangers are built of tubes (round or rectangular in general) mounted in shells (cylindrical, rectangular or arbitrary shape). Many variations of this basic type is available. q § The differences lie mainly in the detailed features of construction and provisions for differential thermal expansion between the tubes and the shell. Shell inlet Tube inlet Tube outlet Shell outlet TFD-HE13 - Shell & Tube Heat Exchager Design 3 Shell & Tube Heat Exchangers U-Tube, baffled, single pass shell & tube heat exchanger Two pass tube, baffled single pass shell & tube heat exchanger Two pass tube, floating head, baffled single pass shell & tube heat exchanger TFD-HE13 - Shell & Tube Heat Exchager Design 4 Shell Types q q TEMA (the Tubular Exchangers Manufacturers Association) publishes standards defining how...

Words: 5860 - Pages: 24

Free Essay

Mea Heat Exchanger Design

...lean/rich MEA heat exchanger E-114. This heat exchanger is a counter flow shell and tube heat exchanger and is designed to heat up the rich MEA stream flowing from the CO2 absorber to the stripper. The principle that is applied is heat exchange between cold stream and hot stream which in this case the heat energy is transferred from the lean MEA stream to the rich MEA stream. Apart from this, the chemical engineering design for this heat exchanger includes the determination of its dimensions and heat exchange coefficient as well as pressure drop. The mechanical design covers the design of pressure vessel, head, supports and piping. In addition, the operating design which includes the commissioning, start-up, shutdown and maintenance procedures, process control, and HAZOP study is considered. 2.0 Process Description Figure 2.1 Schematic of rich/lean MEA heat exchange process flow sheet The lean/rich MEA heat exchange process is presented in Figure 2.1. The MEA-2 stream containing rich CO2 is flowing from CO2 absorber and enters the heat exchanger to be heated up from 61°C to 80°C by MEA-7 before entering the stripper. The MEA-7 is then cooled down from 105°C to 84°C when pass through the heat exchanger and recycle back to the CO2 absorber. The cold stream in this case is MEA-2 and MEA-3 while the hot stream is MEA-7 and MEA-8. 3.0 Chemical Engineering Design 3.1 Design Methodology The rich/lean MEA heat exchanger is a counter flow shell and tube heat exchanger. The chemical...

Words: 3516 - Pages: 15

Premium Essay

Chem Sys

...SHELL & TUBE HEAT EXCHANGER DESIGN TFD-HE13 - Shell & Tube Heat Exchager Design 1 Introduction q Shell & tube heat exchangers are the most versatile type of heat exchangers. § They are used in process industries, in conventional and nuclear power stations, steam generators, etc § They are used in many alternative energy applications including ocean, thermal and geothermal. q Shell & tube heat exchangers provide relatively large ratios of heat transfer area to volume. They can be easily cleaned. q TFD-HE13 - Shell & Tube Heat Exchager Design 2 Shell & Tube Heat Exchangers q Shell & tube type heat exchangers are built of tubes (round or rectangular in general) mounted in shells (cylindrical, rectangular or arbitrary shape). Many variations of this basic type is available. q § The differences lie mainly in the detailed features of construction and provisions for differential thermal expansion between the tubes and the shell. Shell inlet Tube inlet Tube outlet Shell outlet TFD-HE13 - Shell & Tube Heat Exchager Design 3 Shell & Tube Heat Exchangers U-Tube, baffled, single pass shell & tube heat exchanger Two pass tube, baffled single pass shell & tube heat exchanger Two pass tube, floating head, baffled single pass shell & tube heat exchanger TFD-HE13 - Shell & Tube Heat Exchager Design 4 Shell Types q q TEMA (the Tubular Exchangers Manufacturers Association) publishes standards defining how...

Words: 298 - Pages: 2

Free Essay

Heat Exchanger Design

...Design of heat exchangers required for a 50-100kW superheated Rankine cycle MECH 421 Huzeyfe SHAHIN Gokce SAGIR Usman Arshad SHAH 28th December 2015 Table of Contents 1. ABSTRACT .............................................................................................................................................. 3 2. INTRODUCTION ..................................................................................................................................... 3 3. LITERATURE REVIEW ............................................................................................................................. 3 4. SIMPLE DESIGN ..................................................................................................................................... 3 4.1 Evaporator at 800 kPa (Counter Flow) ................................................................................................ 4 4.1.1 Preheater ..................................................................................................................................... 4 4.1.2 Boiler ............................................................................................................................................ 4 4.1.3 Superheater ................................................................................................................................. 5 4.2 Evaporator at 800 kPa (Shell & Tube) ............................................

Words: 6124 - Pages: 25

Free Essay

Haniemadz

...of the Study Heat exchangers have been used extensively and play an important role in the capital cost, energy efficiency and physical size of refrigeration and air conditioning systems. In this dissertation, a simulation tools to improve effectiveness and efficiency in design, rating, and analysis of air to refrigerant heat exchangers including conventional finned tube coils and emerging micro channel heat exchanger, Coil Designers, is developed and investigated using a general-purpose modeling concept and user friendly interface. The basic concept of a heat exchanger is based on the premise that the loss of heat on the high temperature side is exactly the same as the heat gained in the low temperature side after the heat and mass flow through the heat exchanger. Heat exchanger ‘simply’ exchanges the heat between those two sides; as a result, it is decreasing the temperature of higher temperature and increasing the temperature of lower temperature side. But designing heat exchanger might a challenge; it needs iteration for manual calculation. Many factors have to be considered in heat exchanger selection. Generally suitability of types of heat exchanger to be used in processing industrials is selected based on TEMA (Tubular Exchanger Manufacturer Association) Standards. TEMA divides heat exchanger into classes based on their application. A shell a tube heat exchanger is one of the standards designs of heat exchanger. It is most common types of heat exchanger in oil refineries...

Words: 398 - Pages: 2

Free Essay

Spartan Heat Exchange Inc

...partan Heat Exchangers Inc. Group Case Study Spartan Heat Exchangers Inc.   Current State Spartan Heat Exchangers Inc. has been a leading designer and manufacturer of specialized industrial heat transfer equipment for more than 10 years. The company’s primary products are transformer coolers, hydro generator coolers, air-cooled heat exchangers and transformer oil coolers. Their USP are Fin tube type heat exchangers and long lasting products. “… A heat exchanger is a device that is used to transfer thermal energy (enthalpy) between two or more fluids, between a solid surface and a fluid, or between solid particulates and a fluid, at different temperatures and in thermal contact. …” The company is into highly customized heat equipments. Presently, due to entry of new competition from European and Korean companies they have changed their corporate policy, which emphasize on reducing the variety and standardizing the product. The new business policy also aims at reducing the current lead time from 14 weeks to 6 weeks. Problem Statement The Materials Department headed by Rick Coyne has to take many initiatives internally to incorporate the various implications of the new strategy, and submit his report to his boss Max Brisco with the changes suggested by him within a week. The major challenges that Rick faces include: • Change from responsive to anticipatory model of production. • Increase inventory turns from present 4 times to 20 times. • Eliminate material shortages...

Words: 312 - Pages: 2

Free Essay

Process Technology

...Voss PCT 105 Equipment April 5, 2012 Heat Exchangers There are many types of heat exchangers used in a wide variety of industrial applications including power plants, boilers for industrial steam, chemical plants, and many types of manufacturing facilities. Several different configurations are used to accomplish the function of transferring heat from one fluid to another without mixing the two fluids together. The two most common industrial heat exchangers, the shell and tube heat exchanger and the double pipe heat exchanger, along with information about spiral heat exchangers, flat plate heat exchangers, flat plate heat exchangers, fin-tube heat exchangers, and condensers. Calculations for heat exchanger design use heat transfer parameters such as convection heat transfer coefficients, overall heat transfer coefficients, and log mean temperature differences. These calculations are needed for shell and tube and double pipe heat exchangers, as well as other types. The flow pattern through a heat exchanger affects the required heat exchanger surface. A counter flow heat exchanger needs the lowest heat transfer surface area. It gives a higher value for log mean temperature difference than either a parallel flow heat exchanger or a cross flow heat exchanger. A heat exchanger can have several different flow patterns. Counter flow, parallel flow, and crosss flow are common heat exchanger types. A counter flow heat exchanger is the most efficient flow pattern of...

Words: 1476 - Pages: 6

Free Essay

Chemical Engineering Shell and Tube Heat Transfer

...Horizontal Shell and Tube Heat Exchanger Table of Contents: Nomenclature. Pg. 3 Introduction and Background Pg. 4 Experimental Methodology Equipment and Apparatus Pg. 6 Experimental Procedures Pg. 7 Results Pg. 8 Analysis and Discussion……………………………………………………………………..Pg. 11 Summary and Conclusions Pg. 12 References Pg. 13 Appendices Pg. 14 Nomenclature Symbol | Term | Units | A | Heat transfer surface area for the tubes | Inches2 (in2) | Cp | Heat Capacity | J/(mol*K) | F | Correction Factor | __ | | Heat | W | c | Cold Side Heat Duty | W | H | Hot Side Heat Duty | W | Shell Side | Hot Side | __ | T | Temperature | Celsius | ∆T | Change in Temperature | Celsius | Tube Side | Cold Side | __ | ∆Tlm | Log mean temperature difference | Kelvin (K) | U | Heat Transfer Coefficient | W/(K*in2) | V | Volume | L | ṁH | Hot water flow rate | L/min | ṁC | Cold water flow rate | L/min | 1.0 Introduction and Background A heat exchanger is a device designed to efficiently transfer thermal energy from one fluid to another fluid, which can be a liquid or a gas [1]. These fluids do not mix or come into direct contact with each other. Even though all heat exchangers do the same job of passing heat from fluid to fluid, there are various types that work in many different ways. The two most common types of heat exchangers are the shell-and-tube and...

Words: 2748 - Pages: 11

Premium Essay

Essay On Heat Exchanger

...CHAPTER – 1 Introduction:- Heat exchangers are very helpful in chemical process, engineering application and also in daily use applications, such as, dairy industry, chemical industry, environment engineering, power production, air conditioning and also in food industry. Shell & Tube heat exchanger is commonly used in energy industries and petrochemical industry. Plate Heat Exchanger is commonly used in a wide range of chemical process and so many industrial functions. So many effort have been made to increase the heat transfer of heat exchanger, reduce the heat transfer time and also increase the energy utilization. The mixture of fluid (base liquid) and Nanoparticles (nanometer sized) are called 'nanofluid'. Latest technology gives benefit...

Words: 1646 - Pages: 7

Free Essay

Heat Exchangers

...the secondary fluid to the heat exchanger may change with time. This means that in order to maintain a consistent secondary fluid outlet temperature, the heat supplied to the heat exchanger must also vary. This can be achieved by using a control valve on the inlet to the primary side of the heat exchanger, as shown in Figure 13.2.1. Fig. 13.2.1 Typical temperature control of a steam/water shell and tube heat exchanger A control valve is used to vary the flowrate and pressure of the steam so that the heat input to the heat exchanger can be controlled. Modulating the position of the control valve then controls the outlet temperature of the secondary fluid. A sensor on the secondary fluid outlet monitors its temperature, and provides a signal for the controller. The controller compares the actual temperature with the set temperature and, as a result, signals the actuator to adjust the position of the control valve. For a constant heating area and heat transfer coefficient, the rate at which heat is transferred from the steam to the secondary fluid for a particular heat exchanger is determined by the mean temperature difference between the two fluids. A larger difference in mean temperatures will create a large heat transfer rate and vice versa. On partially closing the control valve, the steam pressure and the temperature difference fall. Conversely, if the control valve is opened so that the steam mass flow and hence pressure in the heat exchanger rise, the mean temperature...

Words: 4745 - Pages: 19

Premium Essay

Heat Exchanger Research Paper

...Various Parts of Shell and Tube Heat Exchangers Shell Shell is the container for the shell fluid and the tube bundle is placed inside the shell. Shell is the costliest part of the heat exchanger. Cost of shell and tube heat exchanger sensitively changes with change in the diameter of shell. The clearance between the tube bundle and inner shell wall depends on the type of exchanger. As per the TEMA standard, shell size ranges from 6 in (152 mm) to 60 in (1520 mm). Standard pipes are available up to 24 in size (600 mm NB). If shell size is fabricated by rolling a plate. Shell diameter depends on tube bundle diameter. For fixed tube sheet shell and tube heat exchanger, the gap between shell and tube bundle is minimum, ranging from 10 to 20...

Words: 1200 - Pages: 5

Free Essay

Eg2002 Heat Exchanger

...EG2002 Process Engineering Continuous Assessment Report Heat Exchange Laboratory By Thomas A. Lindie 51011245 School of Engineering University of Aberdeen Kings College 2011-12 Table of Contents Contents Table of Contents I List of Figures II List of Tables II Symbols and Abbreviations III 1. Introduction 1 1.1 Background 1 1.2 Aims and Objectives 1 1.3 Structure of the Report 2 2. Background Theory 3 3. Experimental Methodology 6 4. Results 8 4.1 Tables of Co-Current and Counter-Current flow taken from Result Table 8 4.1.1 Table of Co-Current Flow at Steady State 8 4.1.2 Table of Counter-Current Flow at Steady State 8 4.2 Log Mean Temperature Different (LMTD) Calculations 9 4.3 Calculating the Duty of the HEX and the Efficiency 10 4.4 Graphs of Results for Co-Current and Counter-Current Flow 12 5. Discussion and Analysis 13 5.1 Log Mean Temperature Different (LMTD) Calculation Analysis 13 5.2 Efficiency of the Heat Exchanger 14 5.3 Errors in Laboratory 14 6. Conclusions and Recommendations 15 Bibliography 16 List of Figures Figure 1: 3D View of Shell and Tube heat exchanger taken from http://www.secshellandtube.com/ 3 Figure 2: Shell and Tube heat exchanger flow pattern taken from http://www.cheresources.com/content/articles/heat-transfer/specifying-a-liquid-liquid-heat-exchanger 3 Figure 3: Screenshot taken from co-current experiment on Armfield Programme 7 Figure 4:Graph of Co-Current Flow 12 ...

Words: 3933 - Pages: 16

Free Essay

Classification of Heat Exchangers

...Classification Of Heat Exchangers Introduction Heat: is energy in transit from one mass to another because of a temperature difference between the two. A form of energy associated with the motion of atoms or molecules and transferred from a body at a higher temperature to one at a lower temperature. Heat energy will move from a high energy state to that of a lower energy state. The process will continue until a state of equilibrium is reached. Equilibrium is the energy state where the material is at the same energy level as its surroundings. A heat exchanger is defined as device used to transfer thermal energy (enthalpy) between two or more fluids, between the solid surface and a fluid. The fluids can be single compounds or mixtures. The typical applications of heat exchangers include cooling or heating of fluid stream of concern, evaporation or condensation of multi-component or single fluid stream. They are also used in heat rejection or heat recovery from a system. The heat exchanger: Is a piece of equipment built for efficient heat transfer from one medium to another? The media may be separated by a solid wall, so that they never mix, or they may be in direct contact. Heat exchangers are found in most chemical or mechanical systems. They serve as the system's means of gaining or rejecting heat. Some of the more common applications are found in heating, ventilation and air conditioning (HVAC) systems, radiators on internal combustion engines, boilers, condensers,...

Words: 828 - Pages: 4

Free Essay

Thermal Design

...The topics will includes review of thermodynamics and heat transfer, Heat Exchanger design, Convective and Conductive heat transfer rate calculations, Discussions of all types of heat exchangers, such as Double pipe, Shell and Tube, and Compact heat exchangers. Also Design of cooling towers, Solar collectors, … will be discussed. Perquisites: Thermodynamics, Dynamic, and Heat Transfer. Textbook: Heat Exchangers, Selection and rating by Sadik Kakac, and Hontan Lee, 3rd edition Reference Books: Hand book of heat exchanger design, Solar Energy Conversions Topics Covered:   |Lecture |Topic | |(Hrs, approx.) | | |5 |Review of heat transfer and thermodynamics | |6 |Classification of Heat exchangers | |3 |Basic Design Methods – Logarithmic mean temperature | |3 |F chart Methods and NTU methods | |6 |Force Convection And Single phase heat exchangers ...

Words: 1552 - Pages: 7

Premium Essay

Heat and Mass

...ENGINEERING COLLEGE HEAT & MASS TRANSFER LAB MANUAL ENGINEERING SCIENCES DEPARTMENT HEAT & MASS TRANSFER LAB MANUAL ENGINEERING SCIENCES DEPARTMENT LAB INSTRUCTIONS 1. No late submissions 2. If you miss the submission time, you will be marked zero in that lab 3. If cheating or plagiarism is observed in the lab report, zero will be marked in that lab. 4. Detailed calculations should be shown. 5. Neat work will earn good marks. 6. Graphs should be made by hands. MS excel graphs will not be accepted. LAB MARKS DISTRIBUTION LAB REPORT/ ATTENDENCE | 50% | LAB PERFORMANCE | 10% | MID TERM ASSESMENT/QUIZES | 10% | FINAL LAB ASSESMENT | 30 % | TOTAL | 100% | TABLE OF CONTENTS S.NO | DATE | OBJECTIVE | PAGE NO | SIGNATURE | 1. | | To show that the intensity of radiation on a surface is inversely proportional to the square of the distance of the surface from the source of radiation | | | 2. | | To show the intensity of radiation various as fourth power of source. | | | 3. | | Determination of barrier temperature gradient between two different metals in end to end pressure contact. | | | 4. | | To perform energy balance on air flowing throw a duct heated by cylindrical rod | | | 5. | | To perform energy balance on air flowing throw a duct heated by cylindrical rod using DAQ | | | 6. | | Determination of a mean surface heat transfer coefficient for tubes in 1 to 16 rows...

Words: 4135 - Pages: 17