(this would be if the operatoris running controls for the purpose of checking the meter; otherwise, the QC lockout would not have allowed the patient to be tested prior to getting the controls in acceptable range). 2 Review the test policy and procedure. 3 To get a trade, take all of the reagents and supplies out of the drawer and take the entire GTS to the High Volume Lab of Chemistry, 5th floor McCullough Bldg. 4 If feasible for the testing site, the Nurse Manager/designee or Clinic Manager
Words: 683 - Pages: 3
Practical 2 – UV-Visible Spectroscopy Iron in dietary supplements Introduction UV-Visible spectroscopy is an analytical technique involving measurement of the UV-visible light absorbed by substances, and is therefore commonly used for determining the concentration of a substance in a sample. Many substances absorb energies of particular wavelengths, while transmitting energy of other wavelengths. A UV-visible spectrum is produced when photons that are present in this particular region of
Words: 2220 - Pages: 9
Food Chemistry Food Chemistry 101 (2007) 397–400 www.elsevier.com/locate/foodchem Analytical, Nutritional and Clinical Methods Method development for the determination of manganese in wheat flour by slurry sampling flame atomic absorption spectrometry ´ Rennan G.O. Araujo, Fabio de S. Dias, Samuel M. Macedo, ´ Walter N.L. dos Santos, Sergio L.C. Ferreira * ´ ˆ ´ ´ ´ Universidade Federal da Bahia, Instituto de Quımica, Nucleo de Excelencia em Quımica Analıtica da Bahia, ´ Campus Universitario
Words: 3148 - Pages: 13
as a reference that I understand the concept and calculation of the lab and will send another lab explaining the errors. AA1 - Varian Spectra AA 200 Experiments INTRODUCTION Concept: Atomic absorption spectroscopy (AAS) is a spectra analytical procedure for the quantitative determination of chemical elements employing the absorption of optical radiation (light) by free atoms. It is capable of measuring the concentrations of a wide variety of element in sample. In AAS method measures the light
Words: 2782 - Pages: 12
to copper poisoning which was found to leach from a pot into the soup under high heat and acidic condition. It was also suspected that an organic compound was present in the soup which enhanced the absorption of copper in consumer. Hence, as an analytical chemist, we have to use UV to determine the actual concentration of copper standards and blank using external calibration standards. The result of the test solution was measured by comparing it with the calibration of copper. Introduction The
Words: 2224 - Pages: 9
pathlength of the sample through which the light beam passes, usually expressed in units of cm. ✓ Procedure a) Preparation of solution : 1) Prepare a standard iron solution containing about 0.0702 g of iron per 1000 mL by first calculating the required amount of pure ferrous ammonium sulfate [Fe(NH4)2(SO4)2C6H2O] (FW=392.14). Weigh out the sample using an analytical balance and dissolve this in about 200 mL of deionized water containing 2.5 mL of H2SO4 in a 1 L volumetric
Words: 1156 - Pages: 5
A MULTI-STAKEHOLDER INDUSTRIAL PROJECTS SELECTION: AN ANALYTIC HIERARCHY PROCESS AND ZERO-ONE-GOAL PROGRAMMING APPROACH Salah R. Agha School of Industrial Engineering, Faculty of Engineering, Islamic University-Gaza, Gaza Strip, Phone: 970-599-746-533, aghasr@yahoo.com ABSTRACT This study uses Analytic Hierarchy Process (AHP) and Zero-One Goal Programming(ZOGP) to select the most favorable industrial projects from the viewpoints of three stakeholders, namely, govern mental, consultants and
Words: 3071 - Pages: 13
Challenges within a CMO Purification Process A Case Study of Crossflow Micro- and Ultrafiltration 6th European Downstream Technology Forum September 7, 2010, Sartorius College, Goettingen Agenda I. II. Introduction Overview applications for CFF at RHB III. Case study I & II IV. Strategies to maintain quality Richter-Helm offers services for (co-)development and manufacture of biopharmaceuticals Business Units and Services In- & Out-Licensing Marketing & Sales Contract development
Words: 1064 - Pages: 5
demonstrate the software and the procedures for preparing the instrument. Each group will run a series of calibration standards to generate a calibration curves. The concentrations are given below. Then, one of the "unknown" samples (A or B) should be run. The printer will generate a report of the concentration of Zinc in the sample. We have to be sure which sample we are used. Our laboratory report should describe the functions of the AAS and describe the procedures for preparing the instrument for
Words: 2383 - Pages: 10
indicate when mobilization of minerals from the spongiosa is accompanied by mobilization from the shaft. Further, the balance over a whole lactation is often small in relation to the total quantities of materials analyzed and may be close to the analytical errors of the methods when the diet given is rich in minerals. The present observations may find some application in the determination of certain mineral requirements of lactation. Because the losses of Ca and P are unavoidable, involving the gradual
Words: 3073 - Pages: 13